PRE2017 4 Groep1: Difference between revisions

From Control Systems Technology Group
Jump to navigation Jump to search
Line 219: Line 219:
The range of a drone is also very important. It can vary from 5 km to 650 km of range (Flynt, 2017). Depending on the use, drones can be specified for its range as well. Typically, bigger drones have a bigger range. However, it is not always useful to employ big drones for a certain task. A trade-off has to be considered. If you want to help someone who only needs some medications but is too far away from a first-aid post for a smaller drone, it would be common sense to send a bigger drone with this larger range span. However, this is not cost-efficient, so a smart implementation would be to, for example send these medications way before (s)he actually needs this. This would have to be sensed in advance with the help of the different sensors on the SmartSuit.
The range of a drone is also very important. It can vary from 5 km to 650 km of range (Flynt, 2017). Depending on the use, drones can be specified for its range as well. Typically, bigger drones have a bigger range. However, it is not always useful to employ big drones for a certain task. A trade-off has to be considered. If you want to help someone who only needs some medications but is too far away from a first-aid post for a smaller drone, it would be common sense to send a bigger drone with this larger range span. However, this is not cost-efficient, so a smart implementation would be to, for example send these medications way before (s)he actually needs this. This would have to be sensed in advance with the help of the different sensors on the SmartSuit.


==== Deployment (Connection with SmartSuit) ====


In conclusion, a drone would be a valuable surplus for our SmartSuit. However, once again, we have elected to focus on the suit itself. In future studies, the integration of the drone should be elaborated upon. In the section 'Communication', a brief explanation of the connection between the drone and SmartSuit is given.
Considering the fact that mountaineers expose themselves to extreme conditions, often difficult to reach for humans, drones can be deployed when approaching life-threatening conditions (Examples such as dehydration situations come to mind). In any way, the drone would have to be alarmed in some way through the device. Considering the assumption that everyone owns a working phone with SIM card, distress signals can be send to the (base) stations which would then employ the drone with the desired outcome.
Different options should be possible. The user should be at the highest level of authority at all times. This would mean that the user can always send distress signals themselves, cancel (incorrect) signals, etc. However, when the user is not capable of doing this him/herself (e.g. when the user has fainted), the product should be able to detect this and send a signal autonomously. A working network is here assumed to always be present.
 
 
In conclusion, a drone would be a valuable surplus for our SmartSuit. However, once again, we have elected to focus on the suit itself. In future studies, the integration of the drone should be elaborated upon.


== SmartSuit Design ==
== SmartSuit Design ==

Revision as of 13:20, 21 June 2018

Wiki Report

Group members

Thomas Boot 0988095 Industrial Engineering
Jelte Dirks 0908196 Computer Science and Engineering
Maurits van Riezen 1050246 Software Science
Linh Tran 0936651 Electrical Engineering
Roan Weterings 0888129 Psychology and Technology

Introduction

This wiki summarizes the project we have been working on for the past weeks. For the Course 'Robots Everywhere' we have been asked to develop a new application concerning robotics. In the following wiki, the entire process for developing this new application will be given. Below, the progress of the project is represented. The chronological work document (what we did each week) is given as well. The first step towards this development plan, was brainstorming for several options.

Brainstorm

After initializing the project, the group has come together to discuss several options regarding robotics. They are listed below:

Festival A smartwear bag with necessities for First Aid and Organisation personnel. Drone will automatically bring new supplies when necessary.
Extreme Sports/Exploration Smartwear monitors health, etc. Drone will fly in to bring First aid equipment for self-help, location data will be used to send First Aid personnel if necessary.
Cameraman Smartwear monitors heartrate of many or all people at an event. A location with the highest average heartrate has the most exciting event. The drone will fly to the most exciting event to film footage.
Police aid Drone can fly around for easy patrolling, the drone can be sent to a specific location as a scout, the drone has an easier time chasing someone.
Shock band (unethical) People who leave trash anywhere but a recycling bin will get a small shock. The band has an NFC chip for payments within the event so people will wear and use it, eliminating the hassle with plastic chips and coins as well.

After some discussion, the subject that seemed most interesting to tackle was that of Extreme Sports (highlighted in bold).

Preliminary Research

After defining the subject of the project, research has been done regarding the content of the subject. Before actually developing a new application for extreme sporters, it should be researched whether or not there is an actually issue to solve. Without an actual benefit for the user, the application would have little use. Below, our problem statement and objectives for our application are given. Furthermore, this decision is supported with statistics.

Problem Statement

Extreme sporters find themselves in dangerous situations and are difficult to reach whenever they are in danger. What they need, especially mountaineers, is a method to keep track of their health and alert the rescue posts when necessary.

Objectives

In order to solve the problem at hand, we will design a SmartSuit. The combination of a drone and smartwear will monitor the health of mountaineers, warn them in time of potential dangers, and send help when necessary. In order to achieve this, the SmartSuit should comply to the following things:

  • Provide preventive and qualitative warnings regarding bodily functions. The SmartSuit should be equipped with sensors which monitor all relevant bodily functions.
  • Dispatch a drone whenever the user is in critical condition. This drone can provide preliminary care and can guide the rescue posts to the patient in a swifter manner than ever before.

For this application, the SmartSuit will be focused on mountaineers. However, in future research, the use of this suit might be extended to other extreme sports.

Requirements

The SmartSuit should be able to fulfill following requirements:

  • The SmartSuit should be equipped with sensors and monitor the user's vital functions. These sensor readings should be able to alert the user when in risk/ danger.
  • The SmartSuit must be able to at least monitor the vital functions: breathing, blood circulation and temperature.
  • The SmartSuit should be able to send preventive warnings by triangulating the sensor data and thus estimating the time before arriving in critical condition (using an algorithm).
  • The SmartSuit should be able to "communicate" with the user, i.e. send out a warning when approaching critical conditions.
  • The SmartSuit needs a location tracker (GPS), in order for the rescue squad and drone to track the patient's whereabouts. The drone needs a GPS, microphone, speaker, and camera in order to be eyes on site for the medical personnel.

Users

Main users: mountaineers (may be extended to hikers, rock climbers, etc. in future research)

Statistics

In order to make sure this application would be an actually benefit for the current mountaineers, we have done some research. This research has shown the number of extreme sporters (namely mountaineers) and the number of actual accidents. Both these findings supported our assumption that a SmartSuit could be a valuable product.

Mountaineers/Rock-climbers

  • 47.2 million people have gone trekking (hiking/backpacking) in the united states alone from spring 2016 to spring 2017. (SFIA)
  • “Around 211,000 people (aged 14+, living in England) go climbing or hill walking at least once a month and 84,000 take part at least once a week.” (Gardner, 2015)
  • “25 million people are climbing regularly” (International Federation of Sport Climbing)
  • “Mountain biking has an estimated 8.6 million participants, making it the second-most popular extreme sport” (Jones, 2008)
  • 2.53 million people have gone climbing (traditional/ice/mountaineering) in 2017 in the United States alone. (SFIA)
  • The Royal Dutch Climbing and Mountaineering Federation (NKBV) has +- 59.000 members in 2015 and are growing every year. (NKBV, 2015)
    • 62% male vs 38% female
    • 14% avid climbers, 31% alpinist, 53% mountaineers, 2% other activities

Injuries and causes

It is very difficult to provide actual statistics and data regarding the number of accidents in general. No actual worldwide database with such data can be found. However, we did find statistics regarding injuries in the US. These data are fairly outdated (up till 2006). However, they can be used as a guideline. By this we mean that for the last few decades, the number of accidents has been fluctuating around 100 - 150, by which one could assume these number can be approximated for 2017 as well.

The statistics show that every year, approximately 100 to 150 injuries related to mountaineering occur in the United States alone.

US Mountaineering.jpg

From these accidents, fractures, lacerations and bruises are the most common type of accident. However, these can hardly be prevented. Our SmartSuit can be an asset here, in such way that the user can directly communicate with the drone/ rescue post. However, preventive warnings are of little use here.

If you look one step further, you notice that the most common accident caused by external factors are Hypothermia, Frostbite and mountain sickness. By monitoring vital functions, our SmartSuit could provide preventive warnings and reduce the risk of accidents.

In short, the SmartSuit can reduce the number of accidents by providing warnings for all externally-induced causes (such as Hypothermia). For the other causes, such as fractures, the suit can be used to monitor the bodily functions while help is on the way (e.g. oxygen level) while also provide communication between the user, rescue post and drone. Lastly, using the GPS tracker in the suit, the rescue post can locate the person in question and reduce time needed to provide help.

Pie chart.jpg

(Abegg, 2006)

Based on these findings, it has shown that a large amount of people practice extreme sporters (especially mountaineers). Furthermore, they experience a lack of proper healthcare. By extension, we believe our SmartSuit provides an actual benefit for the user, a solution to an actual issue.

User, Society and Enterprise Aspects

In the following aspect, the USE aspects regarding this application are closely considered.

User demands/needs for Mountaineering

Extreme sports in general:

  • Experiencing raw, awe-inspiring nature
  • Proving one’s own skills to oneself
  • Acquiring mental health benefits
  • Being reached by First Aid in an easier and faster way (Especially important for mountaineering)

Specific needs of importance for Mountaineering/Rock climbing:

  • Heights:
    • Hypoxia/Hypercapnia → Blood sensor
    • Lightning (lethal injuries) → Weather report
    • Pulmonary oedema, cerebral oedema → Altimeter/Barometer monitor speed of ascension
    • Higher ultraviolet exposure → Sunblock textiles
  • Cold:
    • Hypothermia/Frostbite → Temperature sensors
    • Cardiovascular events → Heart rate monitor
    • Hallucinations → Earlier detection of hypothermia
    • Exacerbates if combined with hypoxia and/or dehydration and/or wind
    • Exercise induced asthma, Bronchial hyperreactivity → Microphones, heart rate
  • Overexertion & Overuse:
    • Dehydration/Hyponatremia → Galvanic skin response, Blood sensor
    • Inflammatory tissue damages to fingers and wrists → Tension sensors
    • Overuse injuries

Society's demands/needs:

The following aspects are relevant for society:

  • Not paying too much for healthcare (keeping expensive incidents to a minimum)
  • Increasing the efficiency of healthcare.
  • Advancing technological development in order to make people's lives better.

Enterprise demands/needs:

  • Clear niche market to target and differentiate in.
  • Increasing profit and customer satisfaction.
  • Keep competitive advantage, use SotA technology to distinguish oneself.
  • Increasing corporate social responsibility. Produce products that increase people’s safety to improve one’s brand image.


Since our SmartSuit is mostly relevant for individual users, the User needs outweigh the Society and Enterprise needs. Only the User needs will remain within the real focus of this particular research. Societal and Enterprise impact are a field for future research.

USE Scenario's

In order to once again demonstrate the real use of a SmartSuit, we have described some scenarios in which mountaineers could find themselves. For each of these scenarios, the use of our SmartSuit is demonstrated. These scenarios have been based on conversations with mountaineers, survey results and logical reasoning.

  • A professional mountain climber is climbing a large snowy mountain. Even though he is well prepared, is well aware of the risks and has brought all relevant supplies, he cannot control all variables. When climbing, a blizzard hits, blocking all sight. His heart rate is lowering due to the cold, and in response he tries to hurry (in order to find shelter). In doing so, he overapplies tension to his fingers (severing nerves, which he is not aware of due to the cold). The tension sensors can sense this, and in combination with a lowered heart rate and decrease in skin temperature can deduce the fact that the hiker is likely in danger. It emits a distress signal to the nearby rescue post. A drone is dispatched. Using GPS tracking location, the drone can locate the hiker and guide the rescue squad there. The hiker, who in mean time has received a message that he should stop climbing and take some rest, can communicate through the drone. By preventively alarming the rescue post, the hiker can be brought to the hospital and treat his hands. With a bit of luck, he might just regain feeling in his fingers.
  • A young athlete is seeking for a new way to get a thrill. He decides to go mountain climbing. However, he is not that experienced yet, and is not fully aware of all dangers. When starting, he rushes up the mountain in a streak of adrenaline. However, he quickly feels dizzy and light-headed. The Oximetric sensor in the SmartSuit detects a drop in oxygen level. In combination with a lowered heart rate, the smart-tech warns the athlete that he is climbing too fast and is experiencing altitude sickness. A drone is dispatched with extra oxygen to get the athlete back on track.
  • A hiker is lost in the snowy mountain tops. He starts to panic and realizes he is running out of food supplies. He has no cell phone connection and does not know what to do. He emits a distress beacon that is picked up by the rescue post. The drone scouts the area and finds the shortest path to the hiker. The drone can then either instruct the hiker back to the road or lead the rescue squad to the hiker.
  • A hiker is suddenly feeling nauseous and has no idea what is happening. He uses his SmartSuit to check his vital functions. The non-invasive sensors (e.g. heart rate, temperature, etc.) do not detect any dangers. The suit then turns to invasive sensors, and checks the blood composition. The results return an elevated level of a certain toxin. Apparently, a few hours ago, the hiker mistook some toxic berries for regular berries. The suit reports this, which enables the hiker to call upon a drone and after a while, the drone arrives with an antidote. The hiker administers the antidote, using instructions from the medic (who communicates through the drone). The hiker is then saved from food poisoning and can safely return home.
  • After a rough day, a hiker goes to sleep. That night, his toes get too cold, and the system detects a danger to frostbite. The tech emits alarms to the hiker. 1) The hiker wakes up and can prevent frostbite in time. 2) The hiker does not wake up and the next morning wakes up to find out his toes are affected by frostbite. Being a professional hiker, he knows that rewarming his toes only increases the risk of tissue damage (since he is still exposed to the cold and refreezing could occur). Luckily, the smart tech already detected a drop in temperature and allerted the medics. The medics get there in time to bring the hiker home and treat his foot before any permanent damage is caused.

Taking several scenarios into account. The use of a SmartSuit (in combination with a drone) could drastically increase healthcare efficiency, and prevent pretty horrible situations. The SotA in this tech does not fully rely on the use of a drone, but is more centered around the diagnostic ability of the suit as well as the preventive warnings this suit emits.

Survey Results

A survey was conducted with mountaineers/rock climbers as the target audience. Only three participants responded, one of which a mountaineering teacher. However, all three participant represented actual mountaineers (or mountaineering teacher)and the all responded in a similar manner. Therefore, we have elected to use their answers as a guideline for our research. We are fully aware three respondents are not reliable, but given the nature of their responses and the lack of other participants, we still have drawn some conclusions from the survey.

The survey itself has not been posted on the wiki, since this would only ensure an information overload, however a short summary of the main results is given. These results have been used to support our assumptions, to validate our USE scenarios and to guide the design of the SmartSuit.

The most often occuring issues/conditions reported were falling, long term muscle injuries, and exhaustion, the latter also being identified as a cause of other injuries. The main symptoms of these issues being chafing wounds, muscle injuries and low blood sugar levels. Clothing hardly gets damaged, though they do prefer to cover up as much as possible to protect against the sun. The daily height to climb was reported as being dependant on fitness according to the teacher. 7 single pitches and 2000m were mentioned as well. The participants would be ok with a suit that monitors their bodily functions, as long as the data is not available to just anyone and they have a say in it. The respondents would like the garment to be a t-shirt, as well as light and comfortable and not too noticeable, long sleeve merino shirts were mentioned as a good option. Average climbing times were reported to be 3, 7, and 8 hours. The participants would prefer the suit to measure heart rate, blood pressure, breaths per minute, body temperature, blood sugar levels, stress hormones, oxygen, and pressure. They prefer notifications to be received through sounds or vibrations, with more exact information being available on their phone. One participant would only like to see the odds that the warning was accurate when they ask for it, the rest would like to receive this anyway. One participant would like the suit to last for 10 hours on a charge, two for 72 hours (which will be used to determine the number of batteries needed to power the SmartSuit). The permissible charging times for the suit were reported to be two hours, six hours and eight hours. All participants would prefer a wired connection between suit components over a bluetooth connection even though this is more fragile, to conserve power. The participants would agree to the suit sending their data to nearby rescue posts, but only if used for alarms, and they want the opportunity to disable this functionality. The teacher likes the suit for “guided trips to high altitude mountains with clients who are not self-sufficient”, and another participant mentioned the suit should add to the currently available gear like a phone or gps watch. They also mention they would like it for solitary extreme sporting, but no as much for when in groups as they would rely on others for monitoring.

Drone

This section briefly discusses the application of a drone in the SmartSuit. Since we quickly discovered we would not have time to research both the drone and the SmartSuit itself, we have kept this part at a minimum. In other words, we have done some preliminary research, yet this should be elaborated upon in future research.

Need/Viability

For the suit to be viable, it is essential that actions can be taken once the suit has detected a critical health problem that needs stante pede attention. When such an issue occurs in a city, or even rural area with decent infrastructure, it is fairly easy for emergency medical services to get to the person in question. In fact, when looking at data from 2015 (Mell et al. 2015), gathered from 485 EMS agencies all over the United States, the average time of an EMS unit to arrive at the location where the 911 call was placed was 7 minutes for urban areas. For rural areas, this time was over 14 minutes. The areas were classified using ZIP code information, with rural having a population of less than 2.500, suburban between 2.500 and 50.000 and urban more than 50.000. 625 of the 1.275.529 instances were marked as outliers and were excluded in the study.

One can imagine that in extreme conditions, EMS is not as readily available as on ground level with proper infrastructure. For this reason, companies or non profit organisations arise that provide these services, but not in a traditional manner as you would expect. For instance, the ‘Himalayan Medics’ provide courses and training, besides the regular ‘search & rescue’ services. It is when trained professionals are with you on your journey, that actions can be taken stante pede. If no medical professional is present, someone has to be sent up (or down) the mountain to aid the person that needs help. The time it takes for aid to arrive depends on the location, and can possibly take several hours. Take for instance the mount Everest, the shortest climb from camp to camp -on average- is 3 hours, when the climber is acclimatized to the harsh conditions at such altitudes and crossing sections of mountains like the Khumbu Icefall is definitely not speeding up the process. (s.n., 2016)

To reach a 7 minute response time on average, or let us say 15 minute response time on average, with hand-carried emergency services in such extreme conditions is plain impossible. For this reason, there should be an alternative with decent response times that is triggered when the suit detects an anomaly. Besides an apt response time, adequate care is also very if not more important. It is therefore crucial to not only force a fast response time, but provide the care that is needed on the spot. A study from 2010 (Al-Shaqsi, 2010) shows that response time is too often the performance indicator for EMS even though there is no valid evidence for this to be the case, and present evidence is conflicting this statement. One almost seems to forget that the patient’s health is the goal in this scenario and ought to be used as a performance indicator.

To achieve both a respectable response time combined with adequate medical aid, the suit is linked to a drone station (which will be located next to the rescue post) that can dispatch drones when the suit says it is time for medical aid. Drones, as they are airborne, do not care for rugged terrain or icy slopes, and the 600 meters it takes to go from camp A to camp B which takes climbers hours of time, can be overcome by the drone in a matter of seconds. Not unlike an ambulance which has many tools that are specialized for different parts of the body like the brain, heart, muscles, skin, lungs, etc., drones exist in various sizes that can be specialized for various tasks as well. For certain emergencies, it is best to deploy a small drone that provides quick care in the form of a pill or injection. In such an instance, the size of the drone is rather insignificant as long as it can carry said pill or injection, yet speed is essential in this instance. Emergencies that require more equipment can certainly be facilitated with drones of a large size. In this situation, speed is also of importance and certainly realizable.

Size

The sizes of drones vary from insect-size to large drones up to the size of a small aircraft. Very small drones (up to 50 cm) (Flynt, 2017) can be used as small surveillance for the hiker, or an emergency device (wearable size) to be employed whenever distress/danger is present. This emergency drone could be used to alarm other people for potential danger, or find the nearest person that can help the hiker in need of help. Small drones (up to 2 m) (Flynt, 2017) can be used to send in medicins/water/first-aid kit, etc. It will be employed from a first-aid post to the corresponding hiker. As the somewhat bigger drones are known to be quite fast, with the current fastest drone to reach up to 314.14 km/h (L, 2018), it will be able to be on time and also take the speed of a first respondent in the neighbourhood to be a guide. Obviously, this top speed is not needed, which makes it even more plausible to have drones that can guide humans by foot or car. Medium sized drones are usually carried by two people. These drones are not very useful in this project. Large drones go up to the size of a small airplane. A human-carrying drone already exist, but is not able to pick up a person by itself. A person in great danger could be evacuated by this drone, but a person who is heavily injured cannot take the benefit of it. This would be a great follow-up study to do.

Range

The range of a drone is also very important. It can vary from 5 km to 650 km of range (Flynt, 2017). Depending on the use, drones can be specified for its range as well. Typically, bigger drones have a bigger range. However, it is not always useful to employ big drones for a certain task. A trade-off has to be considered. If you want to help someone who only needs some medications but is too far away from a first-aid post for a smaller drone, it would be common sense to send a bigger drone with this larger range span. However, this is not cost-efficient, so a smart implementation would be to, for example send these medications way before (s)he actually needs this. This would have to be sensed in advance with the help of the different sensors on the SmartSuit.

Deployment (Connection with SmartSuit)

Considering the fact that mountaineers expose themselves to extreme conditions, often difficult to reach for humans, drones can be deployed when approaching life-threatening conditions (Examples such as dehydration situations come to mind). In any way, the drone would have to be alarmed in some way through the device. Considering the assumption that everyone owns a working phone with SIM card, distress signals can be send to the (base) stations which would then employ the drone with the desired outcome. Different options should be possible. The user should be at the highest level of authority at all times. This would mean that the user can always send distress signals themselves, cancel (incorrect) signals, etc. However, when the user is not capable of doing this him/herself (e.g. when the user has fainted), the product should be able to detect this and send a signal autonomously. A working network is here assumed to always be present.


In conclusion, a drone would be a valuable surplus for our SmartSuit. However, once again, we have elected to focus on the suit itself. In future studies, the integration of the drone should be elaborated upon.

SmartSuit Design

Design Plan V3.png

Hiketech wired2.0.jpg

Hiketech2.0.jpg

Base Architecture

BaseArch.JPG

  • Every sensors at least 10 cm away from the nearest MCU (microcontroller unit) gets its own MCU. If the nearest MCU has no free pins, it will also get its own MCU.
  • All MCUs will store data from its sensors, and transmit only when asked for by the master.
  • Any non-sensor subsystems, like the long distance communication, will also have their own MCU’s.
  • Use the CC264R2F since it is extremely small (2x2mm) and can be attached to pretty much any sensor without significantly increasing size. It also has an extremely low power consumption and built-in bluetooth. Exceptions can be made whenever practical.
  • Every MCU gets a ID, starting from 1 to 128. When the main controller loses connection to a MCU, the MCU with the lowest ID still connected to the same subnetwork becomes the master of the subnetwork
    • If a MCU has not received a signal from the master before some time out (even signals addressed to other MCU’s), it will conclude the connection to the master must have broken
    • After signalling to all other sensors on the network that it has taken over, the new master will open a Bluetooth connection to check if the master is actually dead or that a wire is simply broken. If a Bluetooth connection can be made, all data from other sensors on the same network (if any) will be sent to the master.
    • A master or submaster, upon detecting a child-MCU is not responding, will switch on bluetooth for some fixed time to try and attempt a bluetooth connection in case of wire failure.
    • If a child-MCU is already in a subnetwork before it loses connection, will not attempt to reconnect with the master of the subnetwork, but rather whatever master has the lowest ID.
  • Any sensors with a built-in MCU which is not programmable will be given the highest IDs, as they can not take over the network.
    • These sensors will simply shut down when the connection breaks and no other master is in the same network
    • We could possibly attach an extra MCU even to sensors with a built-in MCU if we want even more robustness
  • We should make an effort to find wire locations that will be more likely to have broken wires, and use this to assign MCU IDs more effectively to make sure all sensors will stay connected.


Advantages:

  • Use less pins, so we can use sensors that require a lot of pins (I2C requires only one input and one output pin per node)
    • Use less wires as well, the I2C can run as a single wire to some hub of many sensors, then split
  • A lot of the sensors on our current sensor list have built in MCU’s that are already I2C compatible, so we can connect them to the network for free
  • Allows transfer of data digitally, so no analog inaccuracies.
  • Allows every chip to record data and send it faster in batches, thus freeing up processing power on the main chip to do other computations

Allow use of separate power supplies, so we can use the cool ambient power systems for the relevant sensors only

  • The I2C multi-master system allows a different microcontroller to take over as “master” when the main one breaks, so it can still function and record data when any one MCU is functional
  • Since the SimpleLink CC264R2F has Bluetooth, we can switch communication to Bluetooth in case a wire breaks.
  • Easy and cool enough to demonstrate for prototype


Disadvantages:

  • More power consumption, every MCU needs to be powered
    • If we switch to Bluetooth, even more power needs to be used
  • More work: Every chip has to be programmed
  • Since the main controller can only poll one sensor at a time, it may react a bit slower
  • I2C supports a maximum of 128 MCU’s on a network
  • Even the small chip is still a solid, fragile, hot block that makes the suit less comfortable, especially if we add some padding for protection
  • We probably cannot reprogram the built in MCUs on many of the sensors, so we cannot actually use a lot of the cool features listed above for those sensors.
  • In order to use switch the master node, the I2C connection must be to pins that can be switched to be either input or output. This limits the choice for pins.


Alternative Proposal:

  • Only use I2C for sensors that require too many pins otherwise
    • Saves work
  • Connect every sensor via long wires to the master MCU with analog signals
    • Noise on long analog signals, should not be much on the scale of the suit though
    • Every sensor needs at least two wires directly to the master MCU, so many wires to areas far from the master MCU that have a lot of sensors


For the Prototype:

We can make a basic demonstration using the two ESP32s, since they have Bluetooth capabilities. We can show that after disconnecting a wire, it can connect via Bluetooth, and that even if the main controller is switched off, we can still record data and retrieve it when the main controller is switched back on.

Reasoning behind processor choice:

For the end-product central chips: ESP32 has been chosen because it has the highest processing-power to cost ratio, while having useful features like Bluetooth and an “ultra low power” mode. Furthermore, it contains 48 pins which should be enough. Also, it is already owned by one of the members. The main disadvantage is the high peak-power consumption and its size. For the end-prodcut per-sensor chips: SimpleLink has been chosen. Its main advantage is that it has extremely small variants, allowing the user to easily glue it to sensors without taking significant extra space. The power consumption is also extremely low. It also contains Bluetooth. For the prototype chips: The ESP32 has been chosen again. This is due to the fact that good development boards are available, and they are cheap. It is also useful to use the same chip twice to ensure maximum code reuse.


Reasoning behind the choice for I2C

There are several reasons why SPI was not chosen. The main advantage of I2C is that it is natively supported by the greatest number of our sensors. Moreover, SPI needs four (or three when using microwire) wires while I2C only needs two. It is thus easier to implement compared to SPI. As we want to use as less wires and space for the prototype, fitting everything onto one PCB and processor would be the most ideal case. Furthermore, I2C facilitates low-bandwidth serial communication on the same PCB, which means that more sensors can be soldered to one single PCB, which makes the prototype less bulky. Also, SPI is loosely defined, meaning no standard version is available, thus making firewall cracking easier. The main disadvantage is that it is slow: 400kb/s, over than 10x slower than SPI. This speed needs to be divided over all sensors since they are all connected to the same communication line. What would make SPI a better choice as well is its ability to synchronously send and receive (full duplex mode). Because of these reasons, when actually implementing the design, it could be possible to change to SPI because of its speed, synchronisation and greater range of use. But as has been motivated, I2C has been chosen for the prototype.

Electronics

Processors

Table 1: CPU options

CPU Options
Name: SimpleLink CC264R2F ESP32 AMD Sempron Embedded Kinetis KL28 Arduino Uno/ATmega328
Manufacturer: Texas Instruments Espressif Systems AMD NXP Qualcomm Atmel
Link: http://www.ti.com/product/CC2640R2F/description https://esp32.net (unofficial site) https://www.espressif.com/en/products/hardware/esp32/resources https://www.amd.com/en-us/products/processors/desktop/sempron-cpu# https://www.nxp.com/products/processors-and-microcontrollers/arm-based-processors-and-mcus/kinetis-cortex-m-mcus/l-seriesultra-low-powerm0-plus/kinetis-kl8x-72-96-mhz-secure-ultra-low-power-microcontrollers-mcus-based-on-arm-cortex-m0-plus-core:KL8x ,

https://www.nxp.com/docs/en/data-sheet/MKL28Z512Vxx7.pdf

http://docs-asia.electrocomponents.com/webdocs/0e8b/0900766b80e8ba21.pdf

http://ww1.microchip.com/downloads/en/DeviceDoc/doc7799.pdf

Instruction Set: ARM Xtensia ISA x86-64 ARM RISC
Clock speed: 48 Mhz 240 Mhz 3.2 GHz 96 Mhz 8-16 Mhz
RAM: 2 kb 520kb Requires external RAM 96 kb 1 kb
Power Consumption 5.9 mA (Active)

1.1 μA (Standby)

20-50mA (Not including Bluetooth) 25w (Not found in amps) 9.6 - 12.8 mA 13-21 mA
Size: 2.7 x 2.7 mm – 7 x 7mm (Larger option has more pins and a lower minimal order size) 7 x 7mm (48 pins, 10-13 GIPO’s) Not found, likely to be large. 8x8mm – 14x14mm(82 GIPOS) 5 x 5 mm - 7 x 7 mm
Price (Estimate): €3.57 (up to 50% discount when buying 1000+ units) €2.62 €207.49 €2.33 €1.82
Features: Bluetooth,

Dedicated subchips for AES and RNG

Bluetooth, wifi,

Dedicated subchips for AES, RSA, SHA and RNG

Fast enough to power screen,

Will not function below 0 degrees embedded cooling

Dedicated TRNG generator + accelerators for DES, 3DES, AES, MD5, SHA-1 and SHA256. -
Notes: - Currently in a team member's possession. - Timer inaccurate in extreme temperatures,

flexible input voltage. Very detailed specifications.

Only multiples of 250 available, but an Arduino utilising this chip is currently in a team member's possession.

Sensors

Temperature Sensor

Ideal and State of the Art: The current wearable electronic devices often lack the sensing accuracy due to movement artifacts because of their rigid en bulky size. It is hard to adapt to the soft and deformable skin. They do provide high performance for signal treatment, communication and power management (Magno, 2016). Contrary to those devices, “skin-like” or “epidermal” sensors exist, which have unparalleled accuracy and precision thanks to their thickness and compliant mechanics. The contact with the skin is therefore robust and intimate. The downside of this sensor is that continuous and long time monitoring is currently only possible with wired connections. This would mean that wireless connections only give “on-demand” measurements. Magno et al. (2016) have proposed a wireless transmission and energy harvesting solution working on solar energy. In their conclusion, they found that their setup consumes 2 mW when accurately sampling temperature. This was functional under and self-sustaining under indoor light-conditions, so they proposed another solution with the help of thermal harvesting of the human body itself for further research, to measure the attainability of such a self-sufficient power harvesting method.

Affordable and Realistic for a Prototype: A wireless body temperature sensor system was created, using relatively affordable materials as to make it accessible to financially challenged countries such as Malaysia. It’s main components are an LM35, and uses an XBee and Arduino with WLAN shield to wirelessly connect to the internet. It reportedly has a 0.25 degrees centigrade accuracy when used to measure temperature on a subjects hands. According to the experimenters this is comparable to a commercial thermometer. This type of technology is both wireless and cheap, with an accuracy that could potentially be improved when measuring a more suitable spot instead of hands.

Galvanic Skin Response Sensor

Ideal and State of the Art: A GSR sensor system was designed to be used for continuous measurements from the back of the body, designed to be flexible and have on-board signal processing. The measurement results showed a high correlation with the utilised reference system of standard fingertip electrodes, and when graphs of the reference signal and the new device’s signal were compared, the characteristics were similar enough to deem the device sensitive enough. The design was made flexible by utilising a “foam-type conductive material” so it would mould itself to the shape of the body it is applied to. The attachment system is designed to be easily attachable and detachable to several types of bodywear. (Kim, Kwon, Seo, and Park, 2014)

Affordable and Realistic for a Prototype: Whichever Galvanic Skin Response sensor the teachers are able to provide us with.

Heart Rate Sensor

A small scale heart rate monitor was created using a custom made flexible pressure sensor and an analog anti-interference circuit. The sensor’s response was linear, with a high sensitivity of 13.4 /kPa. The interference circuit removes noise caused by body movements, and when also taking the sensor’s high flexibility into account this sensor proves to be a comfortable long term heart-rate monitoring solution. The system was compared against other currently commercially available solutions and proved to have an equivalent capability. (Shu, Li, Wang, Mi, Li, and Ren, 2015)

Affordable and Realistic for a Prototype: AD8232 Single Lead Heart Rate Monitor with electrodes and wires.


Blood Parameters

One option for measuring blood parameters and other parameters, like pulse rate, arterial blood oxygen saturation and volume changes can be done with the optical technique called Photoplethysmography (PGG). It uses a clip which contains a light source and a detector on opposite sides to detect the cardiovascular pulse wave that propagates through the body. The PPG waves can be described as containing a direct current (DC) component due to venous blood and an alternating current (AC) component due to blood volume changes in the arteries. The principle of the estimation of pathophysiological parameters using PGG is based on differential absorption of near-infrared radiation (NIR) by different chromophores present in the blood of capillaries, when the subject’s finger is exposed to NIR radiation.

After conducting extensive research, we have elected to use the current SotA OCM1 sensor from Taiwan Biophotonics Co. This sensor enables a blood oxygen measurement with only a 3% accuracy range and measures the patient’s heart rate with only 4 bpm variation (TBPC, s.d.). The sensor is relatively low-power consuming and can be implemented in the fingertips or wrists of the suit (where it is most accurate). For our application, the wrist seems the most plausible solution.

Respiration Rate Sensor

As Koch & Dietzel have shown in their research (Koch & Dietzel, 2016), it is entirely possible to produce an array of sensors that can reliably determine respiration rate by measuring body deformations. The sensors in the array are conductive, and deformation of the material changes the conductivity of the material slightly. By placing several sensors in an array, using different directions, a map can be drawn based of the conductivity of each individual sensor. After calibration, this conductivity map can be translated to certain deformation patterns, as the conductivity is determined by the thickness and the deformation radius of the material.

Barometer

Air pressure sensors have developed so far that they can be implemented in smartphones. These sensors measure the atmospheric tides, that are produced by the absorption of solar radiation in water vapor or ozone. The sensors measure this to determine the atmospheric pressure. (Price et al., 2018) There is little holding us back from implementing the same sensors in our smart suit. Sensors at this point are specific enough to even determine what floor a person is walking on. By using sensors that measure changes in atmospheric pressure, the barometer can accurately predict the height of the person (since pressure and haight are strongly correlated). (Ichikari et al., 2015) Currently, the data collected is being transmitted via WiFi. A point of improvement is finding a way to keep the hiker up to date about his height without having to use WiFi. The sensor we will implement in our suit is the BMP280 Barometric Pressure Sensor, manufactured by Bosch Sensortech. (Bosch SensorTech, 2018)This sensor is only a few millimeters large and extremely low-powered (2,7μA power consumption on average). The sensor is accurate up to 0.12 hPa and functions within a range of -40 degrees to 85 degrees (which should suffice for the mountaineering climate).

GPS

Global Positioning System is a method of tracking one’s movement via satelite localization. This space-based system uses the connection between a transmitter (e.g. a smartphone) and a satellite to determine the approximate location and time. This technology proves effective as long as the line of sight to GPS satellites is unobstructed (e.g. not underground). Therefore, GPS tracking is suitable to implement in our suit, as mountains are high and thus clearly detectable by GPS satellites. GPS tracking uses little energy, and can be sustained easily by implementing a solar cell in the smart suit. (Persson, M., Karlsson, D., 2018). The sensor we will implement in our suit is the ZOE-M8B GNSS tracking chip. This sensor, developed by uBlox is precise up to 4 meters and can track movement up to 0,4 m/s and 2 degrees (for the direction) accuracy. It has a special ultra-low power mode called Super-E, which reduces the power consumption to12 mW. (uBlox, 2018) This solves the largest issue of most GPS devices: their massive power consumption. All sensors have been summarised in table 2.

Sensor details overview

Table 2: Sensors for suit (incomplete)

Sensor Details Overview (Not all details were available for all sensors)
Name/Model: Website: Pins (Voltage Range) Size Accuracy and/or Precision Power Consumption Price Location on Suit Needs an extra Micro Controller Unit?
Texas Instruments LM35A (Temperature Sensor) https://www.hackerstore.nl/Artikel/18 V input = 4 V to 30 V

Ground V out = 10 mV per degree Centigrade, linear by approximation

4.699 mm × 4.699 mm 0.5°C Ensured Accuracy (at 25°C)

typical accuracies of ±¼°C at room temperature and ±¾°C over a full −55°C to 150°C temperature range

60 μA €1,70 Our choice; armpits? Yes
BMP280

Barometric Pressure Sensor (Also usable for temperature)

fhttps://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-19.pdf I2C protocol (8 pin)

8 pins: specifics op pagina 35 van document VDD tussen 1.71V en 3.6V VDDIO tussen 1.2 en 3.6V

2.0 mm x 2.5 mm x 0.95 mm ±0.12 hPa (voor Pressure)

±0..5 Celsius (temperatuur)

range van -40 tot 85 graden

2.74 μA gemiddeld

4.16 μA max

€2,86 Needs to be in contact with the air; side No
AD8232 module (heartbeat sensor) http://www.analog.com/media/en/technical-documentation/data-sheets/AD8232.pdf Operating voltage: 3.3V

Single supply operation: 2.0 - 3.5V

4 mm x 4 mm See datasheet 170 μA From €12,60 Chest No
ZOE-M8B GNSS tracking chip https://www.u-blox.com/sites/default/files/ZOE-M8B_DataSheet_%28UBX-17035164%29.pdf I2C Compliant

51 pins: specifics on pagina 16/17

Table with voltage range on pagina 18

4.5 mm x 4.5 mm x 1.0 mm In power saving mode:

Speed: 0.4 m/s Heading: 2 degrees Location: 4.0 m

12 mW in Super-E mode €10,90 A location promoting easy connection with a satellite; shoulder? No
Autonomous smartwatch with flexible sensors for accurate and continuous mapping of skin temperature (Magno et al., 2016) https://ieeexplore.ieee.org/document/7527239/ unreported, system sends processed data

Each sensor is electrically and individually connected to the smartwatch by a flexible anisotropic conductive film which brings every temperature sensors output to an ADC microcontroller’s pin

The dimensions of the rigid board used for the assembly are 45mm x 57mm and each solar cell has dimensions of 35mm x 14mm for a total area 39cm2.

(MSP430FR5969, Texas Instruments) with an internal ADC, energy harvesting circuits (build around the BQ25570, Texas Instrument), and NFC chip (M24LR16E-R, STMicroelectronics) for wireless communication

Wristband delivers a maximum current of 100 µA @ 1.9 V in indoor conditions (i.e. 300 – 500 LUX) and a maximum current of 15 mA @ 1.6 V under the sunlight (system uses it’s own rechargable battery and solar panels, these stats are enough to keep the system sels sustaining indoords.) Order of a few µW in sleep mode, 2mW in acquisition mode, between 2.8 and 3.6 mW when sending data

40mAh lithium rechargeable battery

Unreported The article uses wrists, though presumably other locations would work too. No
Highly wearable galvanic skin response sensor using flexible and conductive polymer foam (Kim, Kwon, SEO and Park, 2014) https://ieeexplore.ieee.org/document/6945148/ "Designed to measure skin conductance levels from 0 to 50 µS. A 3 Hz low pass filter is included in the analog signal processing part. The filtered analog signal is followed by analog-to-digital conversion in a microcontroller (MCU). A digitized signal of 10-bit resolution is wirelessly transmitted through a Bluetooth interface." Only communicates via bluetooth, but we can probably strip out the microcontroller 38.5mm x 42.5mm GalvanicAccuracy.JPG Designed to measure skin conductance levels from 0 to 50 µS. A 3 Hz low pass filter is included in the analog signal processing part. The filtered analog signal is followed by analog-to-digital conversion in a microcontroller (MCU). A digitized signal of 10-bit resolution is wirelessly transmitted through a Bluetooth interface. Unreported Back Yes (Has a built in one, but it’s not good enough)
A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and an Anti-Interference Post Processing Circuit (Shu, Wang, Mi, Li, and Ren, 2015) http://www.mdpi.com/1424-8220/15/2/3224/htm The device responds linearly to the external pressure with the sensitivity around 13.4 kPa−1. Includes built in processor, built in processor is very big (based on pictures) and we should probably replace it

HeartRateOutput.JPG

15 mm × 30 mm (size of the sensing part) The device responds linearly to the external pressure with the sensitivity around 13.4 kPa−1

HeartRateAccuracy.JPG

Unreported Artery location (arm, neck, leg) Yes (built in processor too big)
OCM1 oximetric sensor http://www.tbpchc.com/eng/medical.php?gid=13 1,8 tot 3,6V,

I2C Compatible

8.0mm x 11.4mm x 2.6mm Heart rate: 3bpm variation for a heartrate between 40 en 240 bp (therefore unsuitable during serious hypothermia)

Oxygen: 3% off for an oxygenpercentage between 70 en 100% (therefore unusable in extreme cases as well)

60 mW Unreported Wrist or finger No

Wiring

Currently Available

Adafruit, a company founded in 2005 by MIT graduate Limor Fried with the aim of creating the best online electronics education site and best designed products store for all ages and skill levels. This store also caters to wearable electronics, specifically smart textile solutions (Adafruit Industries, n.d.).

Table 3: Wiring for suit

Adafruit's Smart textiles options (mostly wiring, some sensors)
Name: Size: Price Resistivity Notes
Stainless Thin Conductive Thread - 2 ply 23 meters $5.95 16 Ohms per 0.3 meters

Drives components using under 50 mA

Doesn’t oxidise, like stiff sewing thread. (Safe to wash)
Stainless Medium Conductive Thread - 3 ply 18 meters $6.95 10 Ohms per 0.3 meters

Drives components using under 100 mA

Doesn’t oxidise, like stiff sewing thread. (Safe to wash)
Stainless Steel Conductive Ribbon 5 mm x 1 meter $24.95 2.6 Ohms per 0.3 meters

Drives components using under 500 mA

Doesn’t oxidise, thin, strong, smooth, flexible like textile ribbon. (Safe to wash)
Stainless Steel Conductive Ribbon 17 mm x 1 meter $29.95 1.2 Ohms per 0.3 meters

Drives components using under 1000 mA

Doesn’t oxidise, thin, strong, smooth, flexible like textile ribbon. (Safe to wash)
Pressure-Sensitive Conductive Sheet (Velostat/Linqstat) 28 cm x 28 cm x 0.1 mm $3.95 Volume Resistivity : <500 ohm-cm

Surface Resistivity : < 31,000 ohms/sq.cm

Pressure sensitive, squeezing reduces resistance.

Heat sealable

Conductive Rubber Cord Stretch Sensor 2 mm diameter, 1 meter long $9.95 350 Ohms unstretched, resistance increases by stretching Maximum stretch: 50 - 70% longer than resting length. Takes minutes to revert to original length. Not an exactly linear sensor, resistance may vary.
Conductive Hook & Loop Tape 7.5 cm $7.50 Hook: 1.8 Ohm per sq, Loop: 1.4 Ohm per sq, 0.8 Ohm through mated closure Silver coating, can oxidise.
Flex PCB Material - Pyralux 15 cm x 15 cm $8.95 Unreported Can be cut with scissors or etched with a PCB etching system. Doesn’t crack as easily as copper tape.
Eeonyx Stretchy Variable Resistance Sensor Fabric 33 cm x 30 cm x 0.5 mm $24.95 129 KOhm / square cm surface resistivity in rest, halves when stretched Bidirectionally stretchy. Can be washed.
Knit Jersey Conductive Fabric 20 cm x 20 cm $9.95 46 Ohms per 0.3 m in stretchy direction, 460 Ohms per 0.3 m in less stretchy direction. Uses silver yarn, can oxidise. Dry clean.
Knit Conductive Fabric 20 cm x 20 cm $9.95 1 Ohm per 0.3 m Uses silver yarn, can oxidise. Dry clean. Bit stretchy, not much.
Woven Conductive Fabric 20 cm x 20 cm $4.95 1 Ohm per 0.3 m Users copper & Nickel plated nylon. Dry clean. Does not stretch.


State of the Art

As we were considering wires, it dawned on us that extreme sporters in the mountains are prone to wear and tear, especially when it comes to mountain climbers. It is therefore useful for our wiring to be sturdy enough to deal with these conditions, or possibly self-repair? Luckily, Sun et al. (2014) have researched self-healable conducting wires. In Sun et al. (2014), they have tested wrapping carbon nanotubes (or similarly conducting material like Ag-nanowires) around self-healing polymer. The self-healing polymer amends breakage after approximately 20 seconds, making use of Van der Waals forces without greatly impacting the conductive properties of the wrapped carbon nanotubes. Despite Van der Waals forces being very weak, the number-density range of 1010-1011 cm-2 of the carbon nanotubes produces a high force. Tensile strength after breaking was preserved at around 80% (averaged over aligned carbon nanotube sheet, silver-nanowire network and carbon nanotube network), with 92% as a maximum. The resistance of the different wires has also been tested, with the carbon nanotube sheet being the closest to original resistance at an approximately 120% from original. It is however debatable if these wires are sufficient for our use-case, in which the distance of the wire can be separated enough for the Van der Waals forces to lose their strength. For this reason, we have chosen to leave this option on the table, but decided to not currently utilise it.

Batteries

Lithium-polymer batteries

LiPo batteries are flexible and make use of a dry polymer to which an elektrolyt gel has been added (Replace Direct, 2018). These batteries are only 4mm thick and can be charged entirely within an hour. Some important features are the fact that it is flexible, it has a high cell voltage (3,7V) and it has a high energy and power density.Unfortunately, these batteries are not fit to use in extreme weather, so the only viable option here is to keep them close to the human body. At temperatures above 70 degrees, the battey can expand and get damaged, for example. An example of such batteries is the Apple iPhone 5s accu, with a capacity of 1500mAh and a price of 19,50 euro (123Accu, 2018).


Hermes Lithium-Metal battery

This battery, developed by Solid Energy, is the lightest rechargeable battery on earth.The battery is approximately 6 cm high, 4 cm broad and 6 mm thick. It functions under 3.8V and has a capacity of 3,4 Ah (at 25 degrees). It is flexible and extremely high-density. This battery is currently used in for example drone applications and can withstand temperatures up to 45 degrees, with a minimum of 0 degrees while charging and -20 degrees while discharging. (Solid Energy, s.d.)


GMB Low temperature LiPo battery

This battery uses the same technology as the first described. However, this battery can perform at temperatures from -40 to 45 degrees. It has a capacity of 40 Ah and a nominal voltage of 25.9V. This might be the best solution for our design. (GMB, 2015).

The Algorithm

Health Warnings

Hyper- and Hypothermia Our proof of concept will use a Temperature sensor and a Galvanic skin response sensor. These two sensors can be used to warn people of a potential hypothermia or hyperthermia. When taken separately they can give an approximation of someone’s well being, mostly using averages and estimations. However, as everyone is different, for our application it is important to get a more accurate estimation of someone’s body’s state to base our warnings and actions on.

To get more accurate readings, the sensors will start with baseline measurements of the person in rest. This is to determine their average body temperature and galvanic skin response. For body temperature this is done because the range of possible base temperatures ranges on average from 36.1 to 37.2 degrees centigrade (MedLine Plus team, 2018), and a shift of one degree centigrade in either direction is already enough for a warning; if a person’s core temperature drops by 2 degree centigrade they are already experiencing a mild hypothermia (after a degree drop they experience a severe hypothermia and need medical attention). If a person’s core temperature increases by 1 to 1.5 degrees they either have a fever, or a mild case of hyperthermia. If a person’s body temperature increases by 1.5 to 3 degrees they are experiencing serious hyperthermia, and are in need of medical attention (Calvin, 2018).

Hypothermia.PNG

Figure 1: Accidental hypothermia in severe sepsis. The graph suggests the relationship between inflammation and temperature in severe sepsis. As inflammation increases, temperature accordingly increases. After the point of ‘critical inflammation’ core body temperature drops, this may be an adaptive response to prevent further damage mediated through inflammation.

“Accidental hypothermia” is described as the sudden drop of temperature due to environmental causes. In this figure, one can see that there is a relationship between inflammation and temperature in severe sepsis. At the intersection of the two graphs, “critical inflammation” has been reached, causing hyperthermia to turn into hypothermia. This point can be seen as the point at which the sporter is in great danger and needs medical assistance.

This would mean that a person is “safe” regarding sepsis when (s)he is between 36.1 to 40 degrees Celsius (hyperthermia). When a person hits the 40 degrees and drops down to 32 (hypothermia), one can conclude that the person is under severe sepsis. https://ugpathsoc.wordpress.com/2014/01/15/pyrogens-cryogens-and-bears-oh-my/

Even these measures are estimates based on averages however, and need to be combined with more sensor data for a more accurate warning system. People experiencing dehydration, hypothermia, or hyperthermia have a reduced galvanic skin response, because they stop sweating and their skin dries out. Galvanic skin response tends to rise when sweating, as sweat increases conductivity, and tends to drop when the skin dries up. Activities and movements such as sports can also influence galvanic skin response readings, but these can be attributed accordingly when other sensor data is taken into account (Shariff, Hingorani, Albadawi, 2015), such as heart rate data, which during exercise should be between 50 to 85 % of 220-age (Gholipour, 2018) (This heart rate data will also be used to alarm professional help in case of cardiovascular events). Under hypothermia conditions a person’s heart rate will drop, under hyperthermia conditions a person’s heart rate will initially rise, and eventually drop as the person goes into shock.When most or all spikes in galvanic skin response have been attributed to other causes such as physical activity, what is left is the base galvanic skin response. When this is base higher on average than the baseline measurement, this is indicative of a sweaty skin, when this base is lower on average than the baseline measurement, this means the skin is drying out. There is no such data found on the exact values of when things get dangerous, but what could be done is looking at the derivatives of the increase/decrease of the heart hate associated with hyper/hypothermia.

In the specific conditions our device will be used in hyperthermia seems like a less likely condition, but it can actually still happen through other causes than a high environmental temperature. Another cause for hyperthermia is overexertion. In overexertion the body has produced more heat than it can handle (rather than receiving it from the environment), and will start to sweat until it can no longer do so, making it similar as the other situation yet still relevant to our use case. Another way to therefore detect this situation is to signal a dehydration or hyponatremia in time. A dehydration is a lack of fluids in the body, and hyponatremia is a lack of salts in the body. In the case of hyperthermia the dehydration is caused by excessive sweating, which goes paired with a large loss of salts in the body, meaning in the specific case of hyperthermia, dehydration and hyponatremia go together, and can be predicted by monitoring the amount of salts in a person’s blood. This can be measured using blood sensors mentioned in previous weeks. Blood sodium levels ought to stay between 135 and 145 milliequivalents per liter (Mayo Clinic Staff, 2018); when they fall below this, a person has hyponatremia.

Biketemp.jpg

Figure 1: The body temperature change IN VEINS: oesophageal, tympanic, arterial and jugular venous blood temperature. As can be seen, a linear increase/decrease to cool down/heat up the body, trying to keep the body temperature constant. (Nybo, 2012). f(t) = 0.9e-3*t+T_base

This figure is a comparison of how quickly the body temperature can change in veins. One can calculate that for this particular case, the temperature increase is approximately 0.9e-3 degrees Celsius per second. Recovery has a faster decrease: 0.08 degrees Celsius per second (Nybo, 2012).

BodyTempMin.jpg

In this figure, the heart rate and body temperature have been measured for a person who went from walking (at time 0), to running (at time 5 min), to sitting (at time 35). The different curves show different speeds. The blue curve corresponds to running at 6km/h, red to 8km/h and green to 10km/h. Error bars have been included in this figure meaning that several people participated in this research. So note: Two of the seven subjects gave up 15 and 20 min after running started at 10 km/h because of difficulty maintaining the pace. Therefore, seven datasets collected at each time point, except for 20 min at 10 km/h (n= 6) and from 25 min to 34 min at 10 km/h (n=5) (Iwasaki, 2015). For the algorithm, hiking is more of a “walking-pace” intensity level with an increasing intensity when going on slopes or when actually climbing. Therefore, we will compare this intensity with the red curve (also because the green curve is incomplete). For the heart rate, the increase coincides most with a logarithmic function. Thus, when starting to increase the intensity at time = 5 min: HR = HR_base + 25 + log_1.05425(t+1) per minute. As one can see, the body temperature increases exponentially with 1.00054586 per minute or T = T_base*1.000272893^t, where t is in 30 seconds. As not a lot of data points have been taken, the temperature decrease while resting seems to linearly decrease with T = T_base-0.00333t per 30 sec (Iwasaki et al., 2015).

Dehydration.PNG

Figure 2: Effects of dehydration (Bean 2004:84) http://kilcooleac.com/dehydration-and-fluids-in-running/

As can be seen from the figure 2, it is getting dangerous when someone loses more than 2 kg of fluid. This will result in impairing. Code orange: 2 kg to 4 kg, code red: >4kg. However, these are all absolute losses, which can actually differ from person to person. Figure 2 and 3 (also) show relative weight losses. Now: code green: 0 to 2%, code orange: 2% to 6%, code red: >6%

Physical Performance.PNG

'Figure 3: Relative dehydration risks https://tunedintocycling.com/2012/07/

A galvanic skin response detector is able to measure a person’s hydration level. It is expressed in gain (dB). Figure 9 shows simulated sensitivity. One can see that after drinking, the gain will increase accordingly. This is just a proof that galvanic skin responses work. No further useful conclusions with respect to this project can be made with this information. Asogwa, C., Collins, S., Mclaughlin, P., & Lai, D. (2016). A Galvanic Coupling Method for Assessing Hydration Rates. Electronics, 5(4), 39. https://doi.org/10.3390/electronics5030039

Galvanic.PNG

http://www.ilocis.org/documents/chpt42e.htm

In the link above, there is a section under “Rational indices”, which formulates the equations and how to interpret the results of calculating the HSI (heat stress index) and ITS (index of thermal stress).

Physiological.PNG

Figure 3: Consequences of dehydration (Montain, 1992).

“Although the symptoms of heat illness can vary widely among individuals, heat exhaustion due to dehydration is often evidenced by irritability, sudden fatigue, and lightheadedness, with nausea and headache also possible. Skin color is often pale with normal-to-profuse sweating. Heat stroke is characterized by high core temperature, reddened skin, and normal-to-profuse sweating. Severe heat stroke is characterized by central nervous system dysfunction (eg, loss of motor coordination, delirium), and, in the most serious cases, loss of consciousness leading to coma.“ (Murray, 1996) Murray, R. (1996). Dehydration, Hyperthermia, and Athletes: Science and Practice. Retrieved from https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1318513/pdf/jathtrain00019-0058.pdf

"We found that the magnitude of increase in core temperature and heart rate and the decline in stroke volume were directly related to the body weight loss (and thus dehydration accrued) during exercise. Thus, when subjects exercise at 62% to 67% Vo2max under the present environmental conditions (33°C dry bulb, 50% relative humidity, wind speed 2.5 m/sec), the optimal rate of fluid ingestion to attenuate hyperthermia and cardiovascular drift is the rate that most closely matches fluid loss through sweating, at least until the rate of fluid ingestion replaces 81% of sweat loss."' (Montain, 1992). Montain SJ, Coyle EF. The influence of graded dehydration on hyperthermia and cardiovascular drift during exercise. J Appl Physiol. 1992;73: 1340-1350.

When the suit detects the onset of hypothermia, the drone can be dispatched to send warmer clothes, heat elements, and perhaps a light-weight tent to serve as shelter and protection. When the situation worsens the person will be warned to not actively heat up theri body, and a medical team will be sent to offer professional help. In the case of hyperthermia the drone can be dispatched to send sports drinks to replenish sodium and bring cooling elements. When the situation worsens the person will be warned to no longer ingest any food or drink, and try to cool down actively as much as possible and a team of medical professionnels will be sent. In conclusion, this means there are several options to detect hyperthermia and hypothermia. To detect hypothermia, a galvanic skin response sensor, a heart rate sensor, and a temperature sensor will be utilised. To detect hyperthermia, the galvanic skin response sensor, heart rate sensor, temperature sensor, and sodium level sensor will be utilised.

To combine these sensor readings into a more personal advice, acceptable, risky, and dangerous ranges for each sensor will be compared and combined. When at least two sensors are indicating a risk, a warning will be issued to the wearer, and the wearer will be given the option to decline the dispatch of a drone to send first aid material. When the wearer declines, another warning and drone request will be sent and offered for declination each time another sensor enters the risky range, or a sensor enters the dangerous range. When two or more sensors reach the dangerous range, a request for professional medical attention will be issued and offered for declination.

For the temperature sensor, values in the between baseline - 1 and baseline + 0.5 are ok; values between baseline -1.5 and baseline -1, and baseline +1 and baseline + 1.5 are risky; and values between baseline -2 and baseline -1.5, and baseline +1.5 and +3 are dangerous.

For the sodium level sensor, The ok range is between 140 and 145, the risky range is between 136 and 140, the dangerous range is below 136.

For the galvanic skin response sensor, provided the person is still active which is determined using the heart rate sensor, the ok range is between the midpoint of the baseline measurement and the base of when the person is active and sweating, and the base of when the person is active and sweating. The risky point is between this midpoint and the baseline, and the dangerous range is below the baseline.

Heartrate resp.jpg

This figure shows the relation between heart rate and intensity for normal and abnormal heart rate responses. This curve has to be taken into account when also considering people with a cardiac dysfunction. For this project, when the heart rate increases with time, one can conclude that the intensity of the sport is increasing as well (Chaudhry et al., 2017).

Nes et al. (2013) have developed an equation to calculate the maximum heart rate of a person. This is: HRmax = 211 − (0.64 × age). This is not the only way to calculate this. There are a lot of other equations which have almost similar results as Nes et al. For this project, we have used this one as it is the most general one. If time would have permitted, more accurate equations would have been used which are, e.g, dependent on the gender and age as well.


Height related issues

When people ascend too fast, their blood will expand too fast, sometimes even creating air pockets. This can lead to cerebral and pulmonary oedema, where fluid starts to build up in the brain or lungs. This can be predicted by use of an altimeter to monitor their speed of ascension. This condition is very dangerous, and first aid can’t properly help them. Because of this, when the rate of ascension goes above 305 m a day (Ultimate Kilimanjaro team, 2018), a request for professional help will be offered for declination.

Another problem encounterable at great heights is hypoxia, where the blood oxygen levels are below 60 mm Hg rather than between 75 to 100 mm Hg (Mayo Clinic Staff, 2018). Considering hypoxia can speed up hypothermia, it is important to strictly monitor the blood oxygen levels using the oxygen sensors mentioned in earlier weeks. This too is a condition in which professional help is a necessity. For the altimeter, the ok range of values is between 0 and 250 m per day. The risky area is between 250 and 285 m per day, the dangerous area is 285 m per day and above, with a warning sent at 250 and 285 m per day. Considering everyone is different, and this indicator uses only one sensor, the user will be able to set the dangerous rate of ascension from the standard 305 m per day to a different level as most people attempting dangerous climbs have practiced and trained often and know their body well. For the blood oxygen levels, between 80 and 95 mm Hg is the ok range, between 65 and 80 mm Hg is the risky range, and warrants a warning concerning hypoxia and hypothermia. Levels below 65 warrant offering a declination option for professional help. Not all data is known, so sometimes, only an educated guess is available. However, other tricks can be implemented, like taking the derivative can help “guessing” the problem. For example, heart rates keep changing, this does not mean that when the heart rate increased with 30 beats per minute is necessarily dangerous. There is a factor that is being forgotten which is time. If your heartbeat increases with 30 beats per minute in 10 minutes, this is not a coincidence. However, when this changes within a 10 seconds, one should ring a bell. Therefore, the slope of the increase is a very important characteristic.

Functionality

Reliability

[math]\displaystyle{ ỹ_t = \sum^{n}_{i=0}\phi_i y_{t-i}-\sum^{n}_{j=1}\phi_j ỹ_{t-j}, }[/math]

Literature Research

User Needs

Extreme Sports

Extreme sports in Extreme conditions

Dr. M. Malashenkova (2016), exercise physiologist, has given a definition of extreme sports: “The definition “Extreme” in relation to sport is performed in a hazardous environment and involves great risk. In the modern world of extreme sports, a number of factors require an athlete to have maximum concentration, cope with the stress and physical and emotional mobilisation capabilities. Common to all of these sports are risk-taking, pushing limits (physical and legal) and having fun.” As extreme sports, she recognises: “trekking, paragliding, rock climbing, mountain bike, snorkeling, hot air ballooning, hand gliding, wind surfing, canoeing, sailing, skydiving, surfing, bungee jumping, scuba diving, snowboarding, and skiing” (Malashenkova, 2016). These sports are practiced in a wide variety of locations and in a wide variety of extreme natural conditions to do with “hypoxia, altitude, speed, atmospheric pressure, wind, and temperature”. Some people are capable of adapting to these extreme conditions by increasing functional reserves, though it is unclear if everyone can adapt to such extremes. When conducting research in this area, special attention should be given to safety, medical monitoring, and psychological testing of participants (Malashenkova, 2016).


Sports in extreme conditions: the impact of exercise in cold temperatures on asthma and bronchial hyper-responsiveness in athletes (only abstract available)

Athletes performing outdoor endurance winter sports frequently report exercise-induced asthma (EIA) and bronchial hyperresponsiveness (BHR). EIA is likely caused by the increase in breathing rate; water and heat loss are elevated, and in combination with the increased breathing rate can lead to inflammation of the airways. This can lead to increased parasympathetic nervous activity, likely leading to BHR. Sporters in these conditions ought to be regularly assessed in terms of lung function and BHR. These conditions can be alleviated or cured with medicinal treatment (Carlsen, 2012).


Extreme sports: Extreme physiology. Exercise‐induced pulmonary oedema (only abstract available)

During an extreme triathlon event in australia, certain participants were afflicted with dyspnoea (shortness of breath for an abnormal duration), haemoptysis (coughing up blood), and pulmonary oedema (fluid accumulation in the lungs) (Ma and Dutch, 2013).


Sports and extreme conditions. Cardiovascular incidence in long term exertion and extreme temperatures (heat, cold) (only abstract available)

Extreme sports tend to result in a higher body temperature and more sweating, which can result in dehydration and therefore a lower blood volume. This dehydration can also lead to an inability to regulate body temperature leading to thermal stress and injury such as heat stroke. Extended periods of sweating can lead to hyponatremia; decreased sodium concentration in one’s blood, leading to headaches, nausea, balancing issues, confusion, seizures and coma. Chances of thermal stress due to heat (hyperthermia) can be increased by a hot environment, as well as elevated levels of air humidity. Cold temperatures can result in hypothermia and frostbite (Melin and Savourey, 2001).


Emerging Environmental and Weather Challenges in Outdoor Sports

Because of climate change effects seen around the globe, current advice concerning extreme sports in extreme environments may well have become insufficient. plain weather indications no longer allow for an accurate estimation of heat or cold related illnesses and injuries. Several environmental and weather challenges include:

  • Heat (treat heat related illnesses by developing cardiorespiratory fitness, using pre-cooling and ingestion of cold air, water or ice, acclimatization, and hydration and salt balance strategies)
  • Ultraviolet exposure (skin cancers and sunburn, use sunscreen and UVR (Ultra Violet Ray) protective textiles.)
  • Lightning (lethal injuries, use weather reports, taking shelter if necessary)
  • Air pollution (deteriorating lung functionality, inflammation, immune system issues, bronchitis, asthma, etc.) (higher fitness level, train away from cars)
  • Cold (hypothermia, frostbite, asthma, cardiovascular events, hallucinations, exacerbation through hypoxia, use protective clothing to prevent heat loss, no constricting clothing)
  • Altitude (lower or higher pressure, hypoxia, high altitude sicknesses: pulmonary edema, cerebral edema. Use altitude acclimatization.)
  • Snow and avalanche (asphyxia, compression, hypercapnia, hypoxia, use education, safety gears)
  • Exercise induced asthma and bronchial hyperresponsiveness (use pollen distribution forecasts, antihistamines, immunotherapy, air acclimatisation gear (for cold air))

(Brocherie, Girard and Millet, 2015).


Extreme Sports: Injuries and Medical Coverage

Common injuries sustained from extreme sports include: head injury, wrist injury, fractures, internal injuries, microtrauma to the scrotum, ankle injury, knee injury, overuse injury, stress fractures, ligament and tendon injury, finger injury, concussion, abdominal injury, sunburn, dehydration, hyponatremia, and sleep deprivation. Some new extreme sports even include marathons on the south pole, or in the desert. Protective gear is advised to help alleviate some risk factors. There is a need for better medical coverage, better design of protective equipment, and assistance in event planning. currently it is difficult to handle injuries during a race, and equally difficult to arrange evacuations, because medical personnel needs the same advanced skills as the participants to reach them (Young, 2002).


Extreme Sports as a Precursor to Environmental Sustainability

Extreme sports gained a reputation for being for risk seeking adrenaline junkies, without much recognition for how extreme sports influence one’s relationship with the natural world. The reason to participate in extreme sports is not as shallow as just the adrenaline rush; they trigger deep personal changes in courage and humility amongst other construct (Brymer and Oades, 2009). The emphasis lies on how the sports change the relationship with nature, and how it is experienced (Brymer, Downey and Gray, 2009).

Performing in extreme sports works as a demonstration of human power, resilience, and robustness, which is done because society makes people feel powerless and insignificant. (Le Breton, 2000; Palmer, 2000). According to people in favour of ecopsychology, activities in nature are beneficial to psychological well being. They help kickstart combating environmental problems because they increase interest in the natural world beyond seeing it as a mere resource. This is because these activities help us recognise and realise we are part of the natural world, which helps people to actually adopt more environmentally sustainable practices (Brymer, Downey and Gray, 2009). This means participating in extreme sports would be beneficial to society, the environment, and individuals; provided it can be done in a safer or more controlled manner.


The extreme sports experience: A research report

Participants of extreme sports tend to report 5 main aspects of and/or reasons for participating; Commitment and skill (high levels of preparation and practice) Defining the boundaries (high risk, limited outcome possibilities) On risk (labeling them as risk or thrill seekers is “missing the point”) Feelings of accomplishment and personal insight (“empowering and making life easier to deal with Extraordinary experiences akin to Maslow’s peak experiences (“altered perceptions of time and space, floating and flying, calm and stillness, and self validation experiences” The conclusion is that extreme sports are not about risk taking, according to participants (Brymer, 2009).

Rock Climbing / Mountaineering

Rock climbing injury rates and associated risk factors in a general climbing population (abstract only)

Self-reported measures research; 4.2 injuries per 1000 climbing hours, most injuries are in the realm of overuse (93%). Inflammatory tissue damages in fingers and wrists occurred most often. Older climbers have a lower risk of re-injuring something, whereas males have the highest chances.


Limits to human performance: elevated risks on high mountains

Many mountaineers are exposed to hypoxia, cold, and dehydration. The higher the mountain the lower the success rate and the higher the chance of death upon descending. The most important limiting factor in long term sustained human inhabitation of a certain location is barometric pressure. Decreased barometric pressure leads to decreased oxygen availability, which leads to physical stress. Hypoxia and dehydration exacerbate influence of cold temperatures. Wind chills the body even faster, which under these conditions makes temperatures drop another 25 degrees centigrade.

Space Exploration

Space psychology and psychiatry

Common health problems in space with some degree of relevance to our subject include:

  • Visual Illusions
    • Microgravity causes astronauts often mistake stationary objects as moving, as well as being unable to judge their own movement accurately. This is probably of no relevance on mars considering mars has some gravity. This effect usually lasts between a couple hours and a month at max.
  • Error proneness
    • A significant factor is difficulty with hand-eye coordination due to low gravity. We have never been to mars, but this may also be an issue on mars with some, but unusual gravity
    • A different issue is sleep deprivation, caused possibly by a upset cartesian rhythm. Sleep medication is the second most used type of medication on the ISS, after motion sickness medication.
    • The consistent high-stress of the work of the space-explorers may also be a factor
  • Somatoform disorders
  • (Possibly psychological) Muscle weakness

(Kanas and Manzey, 2008).


Could this be the first mars airplane?

This article details a SOTA airplane, the “Prandtl”, optimized for autonomous flight on Mars. It is a fixed-wing vehicle and not a helicopter-like drone. While the project is still in development, the goal is to make it able to fly for 5 hours, giving it a range of 165 km. However, the next planned test model has a max flight time of only 10 minutes, with a range of 32km. The plane is planned to fly to mars around 2020-2022. The entire design is mostly optimized for gliding and for maximal range needs to be launched from a high altitude, though there is no reason why a more powerful engine could not be attached to a similar design (Levine and Conner, 2017; Gibbs, 2016).


Helicopter could be ‘Scout’ for mars rover This article has some information about a test for a helicopter on mars. It would be used to scout an area for rovers to explore later. There is a functional proof-of-concept. The device would weigh 1 kg and with a have a distance of 1.1 meter from one blade tip to the other (Landau, 2015).

Safe passage: Astronaut care for exploration missions

This article claims safety and health issues are the greatest problem preventing exploration of deep space. Major space-related problems include:

  • Bone loss
    • also, astronauts break bones or sprain joints sometimes due to heavy objects moving through 0 gravity, slamming themselves into walls, or other problems related to low gravity. A average of 0.44 bone breaks or joint sprains are recorded per 14 days on space shuttles.
    • Second most common on the russian MIR, with 32 incidents
  • Cardiovascular Alterations
    • 0.02 incidents every 14 days during space shuttle program
    • The most common problem on the russian MIR, with 32 incidents total
  • Reduced performance
  • Neurological and sensing problems
    • One incident every 14 days on average on the space shuttle
    • “headache” is the third most common incident on the russian MIR, with 17 incidents.
  • Immune system problems
    • probably links to the various other problems, but not directly measurable
  • Insomnia
    • 13 incidents on the russian MIR
  • Muscle problems
  • Neuro Vestibular Adaptation (Motion Sickness)
    • By far the most common problem on the space shuttle, with a average of 2.4 incidents every 14 days.
  • Radiation effects
  • Hearing problems
  • Clinical Capability
    • Exposure to toxins
    • Altered drug reactions
    • Illness
    • Decompression

Most common problems are motion sickness, nasal congestion, and sleep disorders. A interesting observation is that astronauts die disproportionally often in car crashes. The most common medical procedures performed on submarines are:

  • Wound care
  • Suturing
  • Cleansing
  • Nail removal
  • Fluorescein eye examination
  • Incision and drainage of abscess
  • Tooth restoration

(Ball and Evans, 2001).

There is a lot more date in this article about procedures on submarines and antarctic bases. A very useful source for later.


Smartwear Constraints

A review of wearable sensors and systems with application in rehabilitation

Because health care system in the US is not equally distributed across the areas of interest in which health care is needed the most, it becomes increasingly attractive to bring the health care inside the homes of patients. A combination of both ambient and wearable sensor technology would provide the means necessary to bring health care inside the homes of people across the globe. The application of the sensors can be categorized as follows:

  • health and wellness monitoring
  • safety monitoring
  • home rehabilitation
  • assessment of treatment efficacy
  • early detection of disorders

Concluding, the step towards home monitoring and home rehabilitation creates interest into designing and developing wearable sensors and system that provide data and assist remotely (Patel, Park, Bonato, Chan and Rodgers, 2012).

Relevance for our objective: Several wearable sensors mentioned can be applied to extreme sporting wearables in order to facilitate monitoring of the condition of extreme sporters.


Sustainable Wearables: Wearable Technology for Enhancing the Quality of Human Life

Wearables are to be separated from portable devices. Up until recently, wearable devices have provided data, and have not been purposed for assisting the user with other tasks or provide services that go beyond merely showing numbers on a screen. Technologies for sustainable wearables as listed in the article are “Human Data Tracking”, “Human Big Data Analyzing”, “IoT” and “Middleware for Wearables”. As technology has advanced, wearable devices have become smaller and increasingly wireless, providing the user with less fatigue and skin trouble, and the possibility of embedding wearables in smart clothes. Due to the rising possibilities in wearables, data is collected on a massive scale. This data should not be collected just for the sake of collecting data, yet analysed and presented to the user in a meaningful and useful way… wearables have to become “aware-ables”. Currently, wearable devices do not provide this functionality and only show the user his/her own data, aggregated and crammed into a nice diagram or graph. This is where the Internet of Things comes in. IoT, making use of wireless connections, is capable of analysing multiple data sets simultaneously, cross referencing between different inputs, and provide the user with meaningful information that the user can apply to his/her life. Making use of cloud processing, data can be collected at one specific location and processed remotely, before being sent back to the user to be displayed. There are several factors that improve wearable quality of life, prolonged and continuous usage:

  • un-monopolizing
  • unrestrictive
  • observable
  • attentive
  • communicative
  • cost effective
  • low power
  • durable
  • scalable

(Lee, Kim, Ryoo and Shin, 2016)

Relevance for our objective: A clear indication to what is wrong with the current wearable technologies that are being put forward, with a specific problem description and solution. This review and it’s sources provide meaningful guidelines to develop wearable tech that actually provides the user with useful information.


Non-invasive wearable electrochemical sensors: a review

As chemical sensor used to be invasive, wearable chemical sensor were absent in on-body sensing technology departments. As electrochemical sensor are becoming increasingly non-invasive, they find their place in wearable devices and applications such as health-care, sport and military. The specific type of sensors make use of either sweat, tears or saliva, and require (obviously) direct contact with one of the aforementioned fluids. A benefit of these sensors that make use of bodily fluids is that they can continuously provide information about the status of the actor wearing the device. It should be noted that the recognition element is not similar for the types of bodily fluids tested, and therefore, to have the full range of elements recognised, all three bodily fluids should optimally be used while sensing (Bandodkar and Wang, 2014).

Relevance for our objectives: Non invasive way of sensing chemical homeostatic properties of a subject. Can be worn without obstructing extreme sport athletes.


Hybrid System of Electro-Textile based wearable Microstrip Patch Antenna with Tuning Holes

A patch that can be sewn into textile which can emit radio frequencies (Ullah and Baghel, 2015).

Relevance for our objectives: Data collected can be transmitted using this patch. Possibly to phone to relay the data to a specific server.


Flexible and stretchable electronics for wearable healthcare

The market for wearable electronics is growing rapidly, which requires changes in how electronics can be worn around the body. There are several technologies that provide a solution. OLAE, or organic and large area electronics uses thin foils made of PET or PEN onto which conductive “ink” is printed. These foils with printed “ink” form a PCB of no more than 50μm. Layering these separate PCB can produce complex but flexible PCBs. Although, more complex wearable devices might need even thinner chips. Another method of creating these small circuit boards is printing thin-film metals like copper, gold or platinum on polyimide layers. The metallization can be as thin as 1 μm, resulting in the device having a total thickness of about 70 μm (van den Brand et al., 2014).

Not only the thickness and flexibility is an issue when it comes to wearables. Flexibility is another key factor in comfortable wearable design. To provide this attribute, the meander strategy can be applied. Electronic functionality is hereby distributed onto several islands that are connected by meander-shaped interconnects, and embedded onto a stretchable rubber. The meander shaped connectives can stretch -to a certain extent- and provide flexible circuitry options (van den Brand et al., 2014).

In summary: with the ultra-thin processing units that are stretchable -to a certain extent- wearable are able to make real time computations.

Relevance for our objectives: Makes it very easy to integrate processing units into clothes that are comfortable to wear. Wearable sensor can make use of on body computations to provide real time processed information that is of actual use to the wearer.


Micro-Drone for Gas Measurement in Hazardous Scenarios via Remote Sensing

As gas releases, whether they are volitional, meant to do harm, or mother nature, become more prevalent, devices to detect such releases are no unwanted luxury. By combining a drone with gas measurement equipment, gases can be detected from a safe distance. In order to achieve this functionality, the drone makes use of techniques common in nature known as”plume tracking” or “odor-source localization”. The measuring techniques have been tested in both a test chamber, with two standard measurement devices as reference, as well as a field test in a volcanic crater on Lanzarote. The test chamber experiment provided near perfect results compared to the reference devices. The test inside the Lanzarote volcanic crater provided successful results as well, showing a significant low concentration of SO2, a typical volcanic gas. To summarize: the combination of drones and gas measurement devices provide safe possibilities to detect airborne hazards (Bartholmai and Neumann, 2010).

Relevance for our objectives: Detection of extraterrestrial airborne hazards, as well as safe areas and measurement tactics for extreme sporting areas such as high altitudes or remote locations.


Sensors

Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts

Elevated intracranial fluid volume (e.g. a rise in fluids inside your head) can cause intracranial pressure to increase. This is extremely dangerous because this can lead to numerous neurological consequences (i.e. a stroke) or even death. A passive, non-invasive skin patch sensor for the head allows this volume to be measured. The sensor consists of only one baseline component, that is shaped into a rectangular planar spiral. This spiral has a self-resonant frequency response when influenced by external radio frequencies. Any fluid volume change of 10 mL increments can be detected, even through your cranial bone. This has been tested on a dry human skull model, as well as in preliminary human tests. Both have proven successful. In the human tests, two sensors have been used, in order to check the feasibility of using this method in the complex environment that is the human body. For both the dry cranial model and the human tests, the correlation between actual fluid volume changes and the first resonance frequency of the sensor have been determined. Both were high, indicating that the sensor reliably measures any fluid shifts. In short, this electromagnetic resonant sensor might be implemented to prevent strokes, hemorrhages and other neurological consequences (Griffith et al., 2018).

Relevance for our objective: Inserting such a sensor in, for example, a suit might monitor the cerebral conditions of extreme sporters. In such environment, the users need reassurance and constant monitoring of their main bodily functions. Especially in extreme cold or heat, the body might get affected. This sensor monitors whether the sporter suffers from cranial deficiencies.


Autonomous smartwatch with flexible sensors for accurate and continuous mapping of skin temperature

Epidermal sensors that are closely contacted with the skin can monitor cardiovascular health, electrophysiology and dermatology with high precision and in a non-invasive manner. This research has proposed a ultra-low power smartwatch connected to flexible solar modules and a row of epidermal heat sensors. This functions wirelessly and energetically autonomous. Preliminary experiments show how this device is perfect for long-term, precise and non-stop monitoring of the skin temperature (Magno, 2016).

Relevance for our objective: Especially for extreme sporters, but practically for any human in extreme conditions, it is imperative they stay on temperature. This device is easy to use, needs no recharging, and constantly monitors their temperature. It could alert the person when they are getting dangerously cold/ hot, such that this person can take preventive actions. The only environmental constraint is that there has to be adequate sunlight to keep the watch powered. This might be a point of improvement.


Device for generating a detectable signal based upon concentration of at least one substance

This patents proposes a contact device which can be played on the eye, in order to detect physical and chemical parameters in a non-invasive way. Using electromagnetic waves, infrared waves and other, this device can scan the cornea to determine for example the oxygen level in your blood. The blood analysis is performed using eyelid motion and closure of the lid to activate a microminiature radio frequency sensitive transensor. These signals are transmitted to an externally placed receiver, for example on glasses. Some of the parameters that can be monitored are heart rate, respiratory rate, ocular blood flow and blood analysis (Abreu, 2017). This patent is published September 2017, thus SotA.

Relevance for our objective: Easy to implement in a suit. Using glasses, lenses, the most important bodily function (heart rate, oxygen level, etc.) can be constantly monitored. Using lenses, the data can be sent to a smartwatch.


Rapid rate-estimation for cell phones, smart watches, occupancy, and wearables

Using a phosphor-coated broadband white LED that produces light which may be transmitted with an ambient light to a target (for example your wrist or ear), this patent can monitor your respiratory and metabolic parameters and transmit this data to your mobile device or other wearable devices. The transmitted light is scattered and passes through a spectral filter. Based on the waveband/ wavelength range, the detected light may be analyzed to determine vital body functions (such a body fat, heart rate, respiratory functions, etc.) (Benaron, 2015).

Relevance for our objective: This is similar to the user needs for the previous patent. Constant reassurance and preventive measure of vital functions is imperative to ensure the safety of sporters/ astronauts.

Wearable sensors and systems

Connected health has increasingly become a topic of interest. This refers to the use of sensors to monitor patients health. Hybrid systems integrating wireless and e-textile technologies are becoming the application to go to. For example, movement sensors can be strapped to the patients wrists or chest and gather data, which in turn can be send via GPS to caregivers or relatives. The progress of technology has enabled these sensors to be incorporated into clothing, such that a jogger can monitor its heart rate simply by wearing the appropriate shirt. This can be combined with robotics (rehabilitation robotics for example). The use of sensorized gloves improves the robotic therapy that goes paired with stroke rehabilitation. In short, this paper shows how technology is enough developed to implement sensors in daily devices, and that data collected can be used to drive robotic devices and improve customer service (Bonato, 2010).

Relevance for our objective: This paper shows exactly what we aim to develop. Equipping people with sensors that can transmit data to a drone when approaching critical conditions is not impossible anymore. This drone can the use GPS tracking to determine where the patient is, what bodily functions are irregular and provide preliminary care. This gives allerted rescue forces extra time, and provides them with accurate data on the condition of the patient. This reduces the time it takes for effective healthcare to be implemented and might thus increase the lives that are being rescued in time.


Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives

350 million people around the world have diabetes. This chronic disorder requires continuous monitoring. Traditionally, this was done by taking a finger prick everytime. Currently, many patients still use this method.

In the recent years, researchers have developed a continuous glucose monitor (CGM), which is able to continuously measure the glucose level in the blood. Also this method is invasive, but does not require the user to give themselves a shot everytime it is needed. The current CGM products need to be replaced after several days, but are able to give the information at any time. This device can be placed in the arm or in the abdomen. It is not bulky and clothes can easily hide it. The CGM measures a current signal generated by the glucose-oxidase reaction, transmitting information on glucose concentration in the interstitial fluid (Acciaroli, Vettoretti, Facchinetti, and Sparacino, 2018). The SotA CGM sensor has some room for improvement in accuracy and reliability. This is due to the fact that the signal only indirectly reflect the glucose concentration. The signal is derived from the glucose oxidase electrochemical reaction.

The SotA CGM have no “smart” aspect. However, attempts have been made by Lee et al, who wanted to personalise the data by capturing the essential cyclic nature by exploiting e.g. data from prior weeks so the calibration time would decrease.


Wearable and Implantable Sensors: The Patient’s Perspective

A study has been done on a target group above 18 years or older regarding their perspective on wearable and implantable sensors. When participants (turned out to be mainly British) were asked if they suffered from any medical condition, the majority mentioned some type of arthritis (52%). The second most common answer given was hypertension (12%), followed by asthma (11%) and diabetes (10%) (Bergmann, Chandaria, McGregor, 2012). Of all responders, 27% had prior knowledge of wearable sensors. However, only 5% have ever experienced with these devices. These experiences related mainly to heart problems (e.g., pacemaker) and diabetes (e.g., insulin pump). Data showed that the responders would prefer a small, discreet and unobtrusive system with many people referring back to everyday objects. The majority (~85%) preferred the sensors to be non-invasive. However, many of this group (~95%) would wear an invasive device when life saving situations come into play. This topic was repeated in the closed-ended section, without fellow-up items and rephrased as implantable sensor. When the participants were asked where they would like to wear the device 85% answered external, 10.5% said internal and 4.5% left it blank. A median annual spend of £50 was found for the biotechnology that related to their own preference. A total of 62% of the people were willing to wear the device for more than 20 h a day. However, 37% expected it to have a battery life of more than 6 months. The placement of the technology on or in the body is expected to take less than 5 min (59% of the overall number of replies) and 35% of the respondents even think it should be less than 1 min (Bergman et al., 2012).


Wearable Sensors for Remote Health Monitoring

Wearable sensors comprise different types of flexible sensors that can be integrated into textile fiber, clothes, and elastic bands or directly attached to the human body. The sensors are capable of measuring physiological signs such as electrocardiogram (ECG), electromyogram (EMG), heart rate (HR), body temperature, electrodermal activity (EDA), arterial oxygen saturation (SpO2), blood pressure (BP) and respiration rate (RR). In addition, micro-electro-mechanical system (MEMS) based miniature motion sensors such as accelerometers, gyroscopes, and magnetic field sensors are widely used for measuring activity related signals. Invasive sensors: rectal thermometer; unsuited for continuous monitoring purposes. Axillary (armpit, thus non-invasive) temperature measurement is more convenient compared to the above-mentioned methods, but more lossy and inaccurate (Majumder, Mondal and Deen, 2017).


Measurement and Geometric Modelling of Human Spine Posture for Medical Rehabilitation Purposes Using a Wearable Monitoring System Based on Inertial Sensors

Inertial sensors have been used to measure spinal motion, making the data intuitive and user-friendly for the clinicians and patients who use the system. The data can be transformed into meaningful parameters such as rotation, flexion-extension and lateral bending. Theobald measured cervical range of motion with inertial sensors. It was proven that they are a viable and objective method for evaluating spine shapes (Voinea, Butnariu and Mogan, 2016).


State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes—The Need for Novel Non-Invasive Techniques

Currently, the SotA methods for measuring the muscle glycogen have been mainly invasive by means of needles (Elusive Gold Standard). The latest one has been developed by Bergström and is known to cause as little damage as possible, a high quality in minimal time restraints, can take multiple biopsies from one sample and allows measurement of other outcome variables (e.g. fibre typing, muscle damage, respiration, enzyme activity, etc). There have been no non-invasive techniques, except for histochemical measurement and MRS, developed yet for this problem (Greene, Louis, Korostynska and Mason, 2017).


Novel Wireless-Communicating Textiles Made from Multi-Material and Minimally-Invasive Fibers

Current textile used as clothing are able to sense, react and conduct electricity. The next-generation will be able to perform computational operations, thus getting a dynamical role. Active functionalities in a smart textile may include power generation or storage, human interface elements, bio-sensing devices, radio frequency (RF) emission/reception, various assistive technologies such as personal emergency awareness systems and response communication (Stepan, 2014). This article describes the operation of these textiles and the use of antennas (Gorgutsa et al., 2014).

ePatch

Originally, the ePatch is a concept set out to be researched by students of the “Fontys Hogeschool Techniek & Logistiek”, commissioned by the company Yellow Factory situated in Hilversum. The incentive of the research was that Yellow Factory wanted to produce a product for people who build too much tension in their shoulders and neck, resulting in tension headaches. Their intention is to give the user a patch to wear on his/her shoulder, which detects when the muscle strain is too much and then gives either haptic or visual feedback to the user to relax his/her shoulder. This in order to prevent tension headaches that result from lasting muscle tension in the trapezius muscle (neck & shoulder). In order to measure the tension on the muscles, the ePatch uses an electromyogram (EMG) meter. (Costa, Keulen & van Rijsbergen, 2016))

Relevance for our objective: The concepts we can extrapolate from this research is the EMG meter patch, which should be attached around the fingers to measure tension in the fingers. As preventing injuries is more important than healing injuries, the patch should ideally be able to give some type of feedback to the wearer until the wearer has acknowledged to the system that the feedback has been received.

Sodium sensor

Another important blood parameter to monitor is the patient’s salt level (namely its sodium level). What would be the best fit for such a sensor is the newly developed wearable sweat sensor. This plastic and flexible sensor can be easily worn on the wrist and measures you sweat on a molecular level. This molecular tests are then directly sent to a smartphone, and could in our case be sent to whatever transponder the suit will be equipped with. This sensor has only been developed in 2016 by Ali Javey, of the University of California, and is yet difficult to find on the market (hence no clear price indication).

Unfortunately, after doing some research, this kind of sensor is not useful for this project, since it only measures the sodium level the body expels. No indication is given regarding the level of sodium that resides in the blood. The only other form of sensor capable of doing this is a mouth sensor. However, this would be inconvenient for the user to wear. Keeping this in mind, the salt sensor has not yet been integrated into the smartsuit.


Finger pressure sensor

As some avid climbers may have experienced already, injuries to the hand and fingers are common. This probably sounds logical as climbers put increased amounts of weight on just their hands and fingers for which they are not suited by nature, except experiencing an injury to the hand or fingers is definitely not pleasant, as they are used every day, almost continuously. For extreme climbers, taking good care of hands and fingers is especially important. They might just find themselves in extreme conditions, where once the injury has manifested(?) itself, proper actions can not be taken to prevent the injury from worsening and the mission might even have to be aborted. One of the most common injuries is a tendon pulley injury. To understand this injury, one must be at least acquainted with how the fingers work mechanically.

Inside Finger.JPG

Figure 1. Finger pulley anatomy

To start off, fingers have no muscles. The mechanic functioning of the fingers is controlled by muscles in the inside of the forearm, that have tendons attached to the middle and end of the finger bone. You can imagine the finger as a brake cable on a bike. In the image above you can roughly see how this looks anatomically. As discussed in a BMC climbing injury sypmosium in 2016 with presenters. Dr. Volker Schoffl (surgeon, climber 8a) and Dr. Isa Schoffl (Paediatrician, climber 7a+), fingers comprise of 52% of all climber injuries, with pulley injuries being 60% of all finger injuries (31,2% of total injuries). This injury is mainly caused by what is known as the “Crimp grip”.

Crimp Grip.JPG

Figure 2. Crimp Grip

The “Crimp grip”, as shown above, is not a natural position for the hand, and places tremendous amounts of force on the pulleys in the fingers, especially on annular pulleys A2 (Jebson & Steyers, 1997) and A4 (Schöffl et al., 2009). This specific grip combined with sudden slipping of the feet causes many injuries. It is therefore that experienced climbers often prefer other grips, due to either a prior injury or just experience.

Treatment of such an injury is important, as is explained above. However, in order to treat this injury, the climber must be aware that this is happening in their fingers. The sooner this injury is treated properly, the sooner it is alleviated. Inexperienced climbers tend to “climb through the pain”, which results in longer recovery time than is necessary had they properly taken care of it when it first appeared.

One of the signs of a ruptured pulley besides pain is pressure inside the finger, resulting in swelling of the fingers (Crowley, 2016). Gloves that warn you when you strain your fingers too much or that pressure is building inside your finger could significantly reduce the time it takes for extreme climbers to notice that they are putting too much stress on their fingers, or that their grip is wrong. Someya Group has researched and built fabric using carbon nanotubes, graphene and an elastic polymer that could act as a pressure sensitive glove. They have tested it on an artificial blood vessel, and were able to detect pressure changes and the speed of pressure propagation (Lee et al., 2016). The sensing range and sensitivity can be adjusted by changing the thickness of the fibre layer, concentration of the conductive filler in the fibre, pad size and width/length ratio of the transistor.

For the suit, this material would be ideal in detecting if fingers have swollen abnormally, and while it is there anyways, detect when climbers are using the wrong grip, or a grip wrong, resulting in too much pressure on one of the pulleys of the fingers. This can not only improve recovering times, as early indication significantly reduces recovery time (such is the case for basically every injury), but also help prevent the injury in the first place by detecting too much pressure on certain parts of the finger.


Communications

Short- and Medium-Range Standards for Wireless Communication

Four key short-range, low-power, wireless communication standards; Bluetooth (IEEE 802.15.1) (Eliasson et al., 2008), UWB (IEEE 802.15.3), ZigBee (IEEE 802.15.4), and Wi-Fi (IEEE 802.11), predominate in the sensor application domain. They all have different data throughputs and ranges (Lee et al., 2007), as can be seen in Figure 1. Bluetooth has been heavily adopted for body-worn applications; Zigbee or 802.15.4 is used for indoor and outdoor multinode network applications; and UWB supports a variety of applications, ranging from implantable sensors (Yuan et al., 2011) to high-precision geolocation determination (Win et al., 2009). Wi-Fi is usually applied in ambient applications where longer ranges, higher data rates, and immunity to signal attenuation in high blockage environments are required. Table 1 shows all advantages and disadvantages of the four mentioned standards.

Since wireless technology is increasing in the health and sport section, the need for a good battery life is required. Therefore, Bluetooth Smart has been developed. It allows Bluetooth Smart users to connect devices and using significantly less battery life. Since Bluetooth has been integrated in many devices, especially in portable devices, an upgrade to Bluetooth Smart can be done easily.

Another known protocol would be 6LOWPAN driven by low power devices, able to join the cause at low data rates and duty cycles. 6LOWPAN is more like a cloud (Olsson, 2014). It is in need of a wireless internet connection (IPv6) in order to work.

In 2012, the IEEE announced the 802.15.6-2012 protocol for short-range, wireless communications designed for in proximity to or inside a human body with data rates up to 10Mbps. Compliant devices use very low power to minimise the specific absorption rate (SAR) into the body and to increase the battery life. The standard supports quality of service (QoS) and strong security, which include EEG, EKG/ECG, temperature, heart rate, oxygen, and blood pressure.

1-Wire

  • serial protocol: single data line and ground
  • 1 master, several slaves
  • Slaves have unique, unalterable, factory-programmed, 64-bit ID with 8-bit family code
  • 2.8 to 5.25V, parasitic supply to the 1-Wire bus
  • half-duplex bidirectional communication
  • Does not seem applicable to our project.


Taking all available choices into consideration, Bluetooth Smart seems to be the most applicable. Zigbee could also be an implementation.

Table 1: Advantages and disadvantages of the four main communication standards (McGrath et al, 2013).

Commstandards1.jpg

Graph1.JPG

Figure 1: Key protocols for wireless applications (McGrath et al, 2013).


Long-range communication

Communication to the base station

As is widely known, communication to the base station (which in turn communicates with other stations, to the destination) can be done in several ways. One could think of phone calls, text messaging and mobile internet. What is needed to have this communication is a SIM (Subscriber Identification Module) card. As the name suggests, communication to a (base) station is not free. Stations are owned by companies which we pay to make use of. Thus, in the proposal, the user has to have access to the base station using a SIM card. As it is common to already own one (103 customers out of 100 people owning cell phones (EC, 2007), thus likely to have a SIM card in it), our proposal will use this fact to be sure that the wearer of our design has access to the stations.

It is becoming a standard to have a working network everywhere, which means that more stations have to be build to supply the increasing demand. This also means that stations are being built at the most difficult places thought of, just in mountains. Still, this has not been fully realised so alternatives are needed. One could think of Walkies, GPS trackers and satellite phones to communicate with emergency lines. This backup should always be present as well. Our prototype will still work with mobile phone communication, but we keep in mind that not every corner has a working network. For now, we assume that the sporter has active connections at all times, thus the use of SIM cards suffice. When further implemented, alternatives can be programmed and developed using the same codes and algorithms to reach the base station.


Cloud Storage

Nowadays, everything is being stored on some sort of cloud. This cloud storage is increasing, so our design should also consider cloud storage. If the product would come to the market, the enterprise would need a storage place. This is out of the scope and will not be considered any further.

Notification System

Visual and auditory user notification methods for smart-home hazard detector

This device detects developing hazardous levels of smoke or carbon monoxide and gives warning signals using lights (three options), sounds/speech (using a speaker), and alarm horns. The hazard level is accessed and compared to preset threshold levels, based upon which alarms can be activated. The device is designed to tie in with smart-home solutions (Fadell et al., 2014).


Notification system

An application was designed that gathers information from other apps on one’s phone, and places the user on a waiting list. It shares personal information the user allows the app to share, and receives notifications with information or waiting list data (West, 2016).

Future Research

drone uitbreiden

Feedback on the Process

Chronological Workdocument

Planning

The most recent Gantt chart has the most recent approach, planning, milestones, deliverables and task-division overview.

File:OGO Robots Everywhere Gantt V1.pdf

File:OGO Robots Everywhere Gantt V2.pdf

File:OGO Robots Everywhere Gantt V3.pdf

File:OGO Robots Everywhere Gantt V4.pdf

File:OGO Robots Everywhere Gantt V5.pdf

Week 1: The Plan

Deliverables & Milestones

Deliverables:

  • Problem Statement and Objectives
  • Users
  • User Requirements/Needs
  • Approach, Milestones, Deliverables
  • Task Division
  • State of the Art Literature Study (at least 25 scientific papers/patents)
  • Wiki Update


Milestones:

  • Research Non-Invasive Sensors
  • Research Invasive Sensors
  • Research User Needs, Extreme Sports
  • Research Wearable
  • Research User Needs, Space Exploration

Brainstorm

Festival Smartwear bag with necessities for First Aid and Organisation personnel. Drone will automatically bring new supplies when necessary.
Extreme Sports/Exploration Smartwear monitors health, etc. Drone will fly in to bring First aid equipment for self-help, location data will be used to send First Aid personnel if necessary.
Cameraman Smartwear monitors heartrate of many or all people at an event. A location with the highest average heartrate has the most exciting event. The drone will fly to the most exciting event to film footage.
Police aid Drone can fly around for easy patrolling, the drone can be sent to a specific location as a scout, the drone has an easier time chasing someone.
Shock band (unethical) People who leave trash anywhere but a recycling bin will get a small shock. The band has an NFC chip for payments within the event so people will wear and use it, eliminating the hassle with plastic chips and coins as well.

Literature Research/State of the Art

User needs, Extreme Sports

Extreme sports in Extreme conditions

Dr. M. Malashenkova (2016), exercise physiologist, has given a definition of extreme sports: “The definition “Extreme” in relation to sport is performed in a hazardous environment and involves great risk. In the modern world of extreme sports, a number of factors require an athlete to have maximum concentration, cope with the stress and physical and emotional mobilisation capabilities. Common to all of these sports are risk-taking, pushing limits (physical and legal) and having fun.” As extreme sports, she recognises: “trekking, paragliding, rock climbing, mountain bike, snorkeling, hot air ballooning, hand gliding, wind surfing, canoeing, sailing, skydiving, surfing, bungee jumping, scuba diving, snowboarding, and skiing” (Malashenkova, 2016). These sports are practiced in a wide variety of locations and in a wide variety of extreme natural conditions to do with “hypoxia, altitude, speed, atmospheric pressure, wind, and temperature”. Some people are capable of adapting to these extreme conditions by increasing functional reserves, though it is unclear if everyone can adapt to such extremes. When conducting research in this area, special attention should be given to safety, medical monitoring, and psychological testing of participants (Malashenkova, 2016).


Sports in extreme conditions: the impact of exercise in cold temperatures on asthma and bronchial hyper-responsiveness in athletes (only abstract available)

Athletes performing outdoor endurance winter sports frequently report exercise-induced asthma (EIA) and bronchial hyperresponsiveness (BHR). EIA is likely caused by the increase in breathing rate; water and heat loss are elevated, and in combination with the increased breathing rate can lead to inflammation of the airways. This can lead to increased parasympathetic nervous activity, likely leading to BHR. Sporters in these conditions ought to be regularly assessed in terms of lung function and BHR. These conditions can be alleviated or cured with medicinal treatment (Carlsen, 2012).


Extreme sports: Extreme physiology. Exercise‐induced pulmonary oedema (only abstract available)

During an extreme triathlon event in australia, certain participants were afflicted with dyspnoea (shortness of breath for an abnormal duration), haemoptysis (coughing up blood), and pulmonary oedema (fluid accumulation in the lungs) (Ma and Dutch, 2013).


Sports and extreme conditions. Cardiovascular incidence in long term exertion and extreme temperatures (heat, cold) (only abstract available)

Extreme sports tend to result in a higher body temperature and more sweating, which can result in dehydration and therefore a lower blood volume. This dehydration can also lead to an inability to regulate body temperature leading to thermal stress and injury such as heat stroke. Extended periods of sweating can lead to hyponatremia; decreased sodium concentration in one’s blood, leading to headaches, nausea, balancing issues, confusion, seizures and coma. Chances of thermal stress due to heat (hyperthermia) can be increased by a hot environment, as well as elevated levels of air humidity. Cold temperatures can result in hypothermia and frostbite (Melin and Savourey, 2001).


Emerging Environmental and Weather Challenges in Outdoor Sports

Because of climate change effects seen around the globe, current advice concerning extreme sports in extreme environments may well have become insufficient. plain weather indications no longer allow for an accurate estimation of heat or cold related illnesses and injuries. Several environmental and weather challenges include:

  • Heat (treat heat related illnesses by developing cardiorespiratory fitness, using pre-cooling and ingestion of cold air, water or ice, acclimatization, and hydration and salt balance strategies)
  • Ultraviolet exposure (skin cancers and sunburn, use sunscreen and UVR (Ultra Violet Ray) protective textiles.)
  • Lightning (lethal injuries, use weather reports, taking shelter if necessary)
  • Air pollution (deteriorating lung functionality, inflammation, immune system issues, bronchitis, asthma, etc.) (higher fitness level, train away from cars)
  • Cold (hypothermia, frostbite, asthma, cardiovascular events, hallucinations, exacerbation through hypoxia, use protective clothing to prevent heat loss, no constricting clothing)
  • Altitude (lower or higher pressure, hypoxia, high altitude sicknesses: pulmonary edema, cerebral edema. Use altitude acclimatization.)
  • Snow and avalanche (asphyxia, compression, hypercapnia, hypoxia, use education, safety gears)
  • Exercise induced asthma and bronchial hyperresponsiveness (use pollen distribution forecasts, antihistamines, immunotherapy, air acclimatisation gear (for cold air))

(Brocherie, Girard and Millet, 2015).


Extreme Sports: Injuries and Medical Coverage

Common injuries sustained from extreme sports include: head injury, wrist injury, fractures, internal injuries, microtrauma to the scrotum, ankle injury, knee injury, overuse injury, stress fractures, ligament and tendon injury, finger injury, concussion, abdominal injury, sunburn, dehydration, hyponatremia, and sleep deprivation. Some new extreme sports even include marathons on the south pole, or in the desert. Protective gear is advised to help alleviate some risk factors. There is a need for better medical coverage, better design of protective equipment, and assistance in event planning. currently it is difficult to handle injuries during a race, and equally difficult to arrange evacuations, because medical personnel needs the same advanced skills as the participants to reach them (Young, 2002).


Extreme Sports as a Precursor to Environmental Sustainability

Extreme sports gained a reputation for being for risk seeking adrenaline junkies, without much recognition for how extreme sports influence one’s relationship with the natural world. The reason to participate in extreme sports is not as shallow as just the adrenaline rush; they trigger deep personal changes in courage and humility amongst other construct (Brymer and Oades, 2009). The emphasis lies on how the sports change the relationship with nature, and how it is experienced (Brymer, Downey and Gray, 2009).

Performing in extreme sports works as a demonstration of human power, resilience, and robustness, which is done because society makes people feel powerless and insignificant. (Le Breton, 2000; Palmer, 2000). According to people in favour of ecopsychology, activities in nature are beneficial to psychological well being. They help kickstart combating environmental problems because they increase interest in the natural world beyond seeing it as a mere resource. This is because these activities help us recognise and realise we are part of the natural world, which helps people to actually adopt more environmentally sustainable practices (Brymer, Downey and Gray, 2009). This means participating in extreme sports would be beneficial to society, the environment, and individuals; provided it can be done in a safer or more controlled manner.


The extreme sports experience: A research report

Participants of extreme sports tend to report 5 main aspects of and/or reasons for participating; Commitment and skill (high levels of preparation and practice) Defining the boundaries (high risk, limited outcome possibilities) On risk (labeling them as risk or thrill seekers is “missing the point”) Feelings of accomplishment and personal insight (“empowering and making life easier to deal with Extraordinary experiences akin to Maslow’s peak experiences (“altered perceptions of time and space, floating and flying, calm and stillness, and self validation experiences” The conclusion is that extreme sports are not about risk taking, according to participants (Brymer, 2009).


Summarised User needs:

  • Experiencing raw, awe-inspiring nature
  • Proving one's own skills to oneself
  • Acquiring mental health benefits
  • Being reached by First aid in an easier way
  • Less risk of:
    • Altitude/Atmospheric pressure
    • Temperature
    • Hypoxia/Hypercapnnia
    • Exercise-induced Asthma/Broncial Hyperresponsiveness
    • Dyspnoea
    • Haemoptysis
    • Pulmonary oedema
    • Hyponatremia
    • Injuries and Fractrures

User needs, Space Exploration

Space psychology and psychiatry

Common health problems in space with some degree of relevance to our subject include:

  • Visual Illusions
    • Microgravity causes astronauts often mistake stationary objects as moving, as well as being unable to judge their own movement accurately. This is probably of no relevance on mars considering mars has some gravity. This effect usually lasts between a couple hours and a month at max.
  • Error proneness
    • A significant factor is difficulty with hand-eye coordination due to low gravity. We have never been to mars, but this may also be an issue on mars with some, but unusual gravity
    • A different issue is sleep deprivation, caused possibly by a upset cartesian rhythm. Sleep medication is the second most used type of medication on the ISS, after motion sickness medication.
    • The consistent high-stress of the work of the space-explorers may also be a factor
  • Somatoform disorders
  • (Possibly psychological) Muscle weakness

(Kanas and Manzey, 2008).


Could this be the first mars airplane?

This article details a SOTA airplane, the “Prandtl”, optimized for autonomous flight on Mars. It is a fixed-wing vehicle and not a helicopter-like drone. While the project is still in development, the goal is to make it able to fly for 5 hours, giving it a range of 165 km. However, the next planned test model has a max flight time of only 10 minutes, with a range of 32km. The plane is planned to fly to mars around 2020-2022. The entire design is mostly optimized for gliding and for maximal range needs to be launched from a high altitude, though there is no reason why a more powerful engine could not be attached to a similar design (Levine and Conner, 2017; Gibbs, 2016).


Helicopter could be ‘Scout’ for mars rover This article has some information about a test for a helicopter on mars. It would be used to scout an area for rovers to explore later. There is a functional proof-of-concept. The device would weigh 1 kg and with a have a distance of 1.1 meter from one blade tip to the other (Landau, 2015).

Safe passage: Astronaut care for exploration missions

This article claims safety and health issues are the greatest problem preventing exploration of deep space. Major space-related problems include:

  • Bone loss
    • also, astronauts break bones or sprain joints sometimes due to heavy objects moving through 0 gravity, slamming themselves into walls, or other problems related to low gravity. A average of 0.44 bone breaks or joint sprains are recorded per 14 days on space shuttles.
    • Second most common on the russian MIR, with 32 incidents
  • Cardiovascular Alterations
    • 0.02 incidents every 14 days during space shuttle program
    • The most common problem on the russian MIR, with 32 incidents total
  • Reduced performance
  • Neurological and sensing problems
    • One incident every 14 days on average on the space shuttle
    • “headache” is the third most common incident on the russian MIR, with 17 incidents.
  • Immune system problems
    • probably links to the various other problems, but not directly measurable
  • Insomnia
    • 13 incidents on the russian MIR
  • Muscle problems
  • Neuro Vestibular Adaptation (Motion Sickness)
    • By far the most common problem on the space shuttle, with a average of 2.4 incidents every 14 days.
  • Radiation effects
  • Hearing problems
  • Clinical Capability
    • Exposure to toxins
    • Altered drug reactions
    • Illness
    • Decompression

Most common problems are motion sickness, nasal congestion, and sleep disorders. A interesting observation is that astronauts die disproportionally often in car crashes. The most common medical procedures performed on submarines are:

  • Wound care
  • Suturing
  • Cleansing
  • Nail removal
  • Fluorescein eye examination
  • Incision and drainage of abscess
  • Tooth restoration

(Ball and Evans, 2001).

There is a lot more date in this article about procedures on submarines and antarctic bases. A very useful source for later.

Constraints, Smart Wear

A review of wearable sensors and systems with application in rehabilitation

Because health care system in the US is not equally distributed across the areas of interest in which health care is needed the most, it becomes increasingly attractive to bring the health care inside the homes of patients. A combination of both ambient and wearable sensor technology would provide the means necessary to bring health care inside the homes of people across the globe. The application of the sensors can be categorized as follows:

  • health and wellness monitoring
  • safety monitoring
  • home rehabilitation
  • assessment of treatment efficacy
  • early detection of disorders

Concluding, the step towards home monitoring and home rehabilitation creates interest into designing and developing wearable sensors and system that provide data and assist remotely (Patel, Park, Bonato, Chan and Rodgers, 2012).

Relevance for our objective: Several wearable sensors mentioned can be applied to extreme sporting wearables in order to facilitate monitoring of the condition of extreme sporters.


Sustainable Wearables: Wearable Technology for Enhancing the Quality of Human Life

Wearables are to be separated from portable devices. Up until recently, wearable devices have provided data, and have not been purposed for assisting the user with other tasks or provide services that go beyond merely showing numbers on a screen. Technologies for sustainable wearables as listed in the article are “Human Data Tracking”, “Human Big Data Analyzing”, “IoT” and “Middleware for Wearables”. As technology has advanced, wearable devices have become smaller and increasingly wireless, providing the user with less fatigue and skin trouble, and the possibility of embedding wearables in smart clothes. Due to the rising possibilities in wearables, data is collected on a massive scale. This data should not be collected just for the sake of collecting data, yet analysed and presented to the user in a meaningful and useful way… wearables have to become “aware-ables”. Currently, wearable devices do not provide this functionality and only show the user his/her own data, aggregated and crammed into a nice diagram or graph. This is where the Internet of Things comes in. IoT, making use of wireless connections, is capable of analysing multiple data sets simultaneously, cross referencing between different inputs, and provide the user with meaningful information that the user can apply to his/her life. Making use of cloud processing, data can be collected at one specific location and processed remotely, before being sent back to the user to be displayed. There are several factors that improve wearable quality of life, prolonged and continuous usage:

  • un-monopolizing
  • unrestrictive
  • observable
  • attentive
  • communicative
  • cost effective
  • low power
  • durable
  • scalable

(Lee, Kim, Ryoo and Shin, 2016)

Relevance for our objective: A clear indication to what is wrong with the current wearable technologies that are being put forward, with a specific problem description and solution. This review and it’s sources provide meaningful guidelines to develop wearable tech that actually provides the user with useful information.


Non-invasive wearable electrochemical sensors: a review

As chemical sensor used to be invasive, wearable chemical sensor were absent in on-body sensing technology departments. As electrochemical sensor are becoming increasingly non-invasive, they find their place in wearable devices and applications such as health-care, sport and military. The specific type of sensors make use of either sweat, tears or saliva, and require (obviously) direct contact with one of the aforementioned fluids. A benefit of these sensors that make use of bodily fluids is that they can continuously provide information about the status of the actor wearing the device. It should be noted that the recognition element is not similar for the types of bodily fluids tested, and therefore, to have the full range of elements recognised, all three bodily fluids should optimally be used while sensing (Bandodkar and Wang, 2014).

Relevance for our objectives: Non invasive way of sensing chemical homeostatic properties of a subject. Can be worn without obstructing extreme sport athletes.


Hybrid System of Electro-Textile based wearable Microstrip Patch Antenna with Tuning Holes

A patch that can be sewn into textile which can emit radio frequencies (Ullah and Baghel, 2015).

Relevance for our objectives: Data collected can be transmitted using this patch. Possibly to phone to relay the data to a specific server.


Flexible and stretchable electronics for wearable healthcare

The market for wearable electronics is growing rapidly, which requires changes in how electronics can be worn around the body. There are several technologies that provide a solution. OLAE, or organic and large area electronics uses thin foils made of PET or PEN onto which conductive “ink” is printed. These foils with printed “ink” form a PCB of no more than 50μm. Layering these separate PCB can produce complex but flexible PCBs. Although, more complex wearable devices might need even thinner chips. Another method of creating these small circuit boards is printing thin-film metals like copper, gold or platinum on polyimide layers. The metallization can be as thin as 1 μm, resulting in the device having a total thickness of about 70 μm (van den Brand et al., 2014).

Not only the thickness and flexibility is an issue when it comes to wearables. Flexibility is another key factor in comfortable wearable design. To provide this attribute, the meander strategy can be applied. Electronic functionality is hereby distributed onto several islands that are connected by meander-shaped interconnects, and embedded onto a stretchable rubber. The meander shaped connectives can stretch -to a certain extent- and provide flexible circuitry options (van den Brand et al., 2014).

In summary: with the ultra-thin processing units that are stretchable -to a certain extent- wearable are able to make real time computations.

Relevance for our objectives: Makes it very easy to integrate processing units into clothes that are comfortable to wear. Wearable sensor can make use of on body computations to provide real time processed information that is of actual use to the wearer.


Micro-Drone for Gas Measurement in Hazardous Scenarios via Remote Sensing

As gas releases, whether they are volitional, meant to do harm, or mother nature, become more prevalent, devices to detect such releases are no unwanted luxury. By combining a drone with gas measurement equipment, gases can be detected from a safe distance. In order to achieve this functionality, the drone makes use of techniques common in nature known as”plume tracking” or “odor-source localization”. The measuring techniques have been tested in both a test chamber, with two standard measurement devices as reference, as well as a field test in a volcanic crater on Lanzarote. The test chamber experiment provided near perfect results compared to the reference devices. The test inside the Lanzarote volcanic crater provided successful results as well, showing a significant low concentration of SO2, a typical volcanic gas. To summarize: the combination of drones and gas measurement devices provide safe possibilities to detect airborne hazards (Bartholmai and Neumann, 2010).

Relevance for our objectives: Detection of extraterrestrial airborne hazards, as well as safe areas and measurement tactics for extreme sporting areas such as high altitudes or remote locations.

Sensors, Non-Invasive

Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts

Elevated intracranial fluid volume (e.g. a rise in fluids inside your head) can cause intracranial pressure to increase. This is extremely dangerous because this can lead to numerous neurological consequences (i.e. a stroke) or even death. A passive, non-invasive skin patch sensor for the head allows this volume to be measured. The sensor consists of only one baseline component, that is shaped into a rectangular planar spiral. This spiral has a self-resonant frequency response when influenced by external radio frequencies. Any fluid volume change of 10 mL increments can be detected, even through your cranial bone. This has been tested on a dry human skull model, as well as in preliminary human tests. Both have proven successful. In the human tests, two sensors have been used, in order to check the feasibility of using this method in the complex environment that is the human body. For both the dry cranial model and the human tests, the correlation between actual fluid volume changes and the first resonance frequency of the sensor have been determined. Both were high, indicating that the sensor reliably measures any fluid shifts. In short, this electromagnetic resonant sensor might be implemented to prevent strokes, hemorrhages and other neurological consequences (Griffith et al., 2018).

Relevance for our objective: Inserting such a sensor in, for example, a suit might monitor the cerebral conditions of extreme sporters. In such environment, the users need reassurance and constant monitoring of their main bodily functions. Especially in extreme cold or heat, the body might get affected. This sensor monitors whether the sporter suffers from cranial deficiencies.


Autonomous smartwatch with flexible sensors for accurate and continuous mapping of skin temperature

Epidermal sensors that are closely contacted with the skin can monitor cardiovascular health, electrophysiology and dermatology with high precision and in a non-invasive manner. This research has proposed a ultra-low power smartwatch connected to flexible solar modules and a row of epidermal heat sensors. This functions wirelessly and energetically autonomous. Preliminary experiments show how this device is perfect for long-term, precise and non-stop monitoring of the skin temperature (Magno, 2016).

Relevance for our objective: Especially for extreme sporters, but practically for any human in extreme conditions, it is imperative they stay on temperature. This device is easy to use, needs no recharging, and constantly monitors their temperature. It could alert the person when they are getting dangerously cold/ hot, such that this person can take preventive actions. The only environmental constraint is that there has to be adequate sunlight to keep the watch powered. This might be a point of improvement.


Device for generating a detectable signal based upon concentration of at least one substance

This patents proposes a contact device which can be played on the eye, in order to detect physical and chemical parameters in a non-invasive way. Using electromagnetic waves, infrared waves and other, this device can scan the cornea to determine for example the oxygen level in your blood. The blood analysis is performed using eyelid motion and closure of the lid to activate a microminiature radio frequency sensitive transensor. These signals are transmitted to an externally placed receiver, for example on glasses. Some of the parameters that can be monitored are heart rate, respiratory rate, ocular blood flow and blood analysis (Abreu, 2017). This patent is published September 2017, thus SotA.

Relevance for our objective: Easy to implement in a suit. Using glasses, lenses, the most important bodily function (heart rate, oxygen level, etc.) can be constantly monitored. Using lenses, the data can be sent to a smartwatch.


Rapid rate-estimation for cell phones, smart watches, occupancy, and wearables

Using a phosphor-coated broadband white LED that produces light which may be transmitted with an ambient light to a target (for example your wrist or ear), this patent can monitor your respiratory and metabolic parameters and transmit this data to your mobile device or other wearable devices. The transmitted light is scattered and passes through a spectral filter. Based on the waveband/ wavelength range, the detected light may be analyzed to determine vital body functions (such a body fat, heart rate, respiratory functions, etc.) (Benaron, 2015).

Relevance for our objective: This is similar to the user needs for the previous patent. Constant reassurance and preventive measure of vital functions is imperative to ensure the safety of sporters/ astronauts.


Wearable sensors and systems

Connected health has increasingly become a topic of interest. This refers to the use of sensors to monitor patients health. Hybrid systems integrating wireless and e-textile technologies are becoming the application to go to. For example, movement sensors can be strapped to the patients wrists or chest and gather data, which in turn can be send via GPS to caregivers or relatives. The progress of technology has enabled these sensors to be incorporated into clothing, such that a jogger can monitor its heart rate simply by wearing the appropriate shirt. This can be combined with robotics (rehabilitation robotics for example). The use of sensorized gloves improves the robotic therapy that goes paired with stroke rehabilitation. In short, this paper shows how technology is enough developed to implement sensors in daily devices, and that data collected can be used to drive robotic devices and improve customer service (Bonato, 2010).

Relevance for our objective: This paper shows exactly what we aim to develop. Equipping people with sensors that can transmit data to a drone when approaching critical conditions is not impossible anymore. This drone can the use GPS tracking to determine where the patient is, what bodily functions are irregular and provide preliminary care. This gives allerted rescue forces extra time, and provides them with accurate data on the condition of the patient. This reduces the time it takes for effective healthcare to be implemented and might thus increase the lives that are being rescued in time.

Sensors, Invasive

Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives

350 million people around the world have diabetes. This chronic disorder requires continuous monitoring. Traditionally, this was done by taking a finger prick everytime. Currently, many patients still use this method.

In the recent years, researchers have developed a continuous glucose monitor (CGM), which is able to continuously measure the glucose level in the blood. Also this method is invasive, but does not require the user to give themselves a shot everytime it is needed. The current CGM products need to be replaced after several days, but are able to give the information at any time. This device can be placed in the arm or in the abdomen. It is not bulky and clothes can easily hide it. The CGM measures a current signal generated by the glucose-oxidase reaction, transmitting information on glucose concentration in the interstitial fluid (Acciaroli, Vettoretti, Facchinetti, and Sparacino, 2018). The SotA CGM sensor has some room for improvement in accuracy and reliability. This is due to the fact that the signal only indirectly reflect the glucose concentration. The signal is derived from the glucose oxidase electrochemical reaction.

The SotA CGM have no “smart” aspect. However, attempts have been made by Lee et al, who wanted to personalise the data by capturing the essential cyclic nature by exploiting e.g. data from prior weeks so the calibration time would decrease.


Wearable and Implantable Sensors: The Patient’s Perspective

A study has been done on a target group above 18 years or older regarding their perspective on wearable and implantable sensors. When participants (turned out to be mainly British) were asked if they suffered from any medical condition, the majority mentioned some type of arthritis (52%). The second most common answer given was hypertension (12%), followed by asthma (11%) and diabetes (10%) (Bergmann, Chandaria, McGregor, 2012). Of all responders, 27% had prior knowledge of wearable sensors. However, only 5% have ever experienced with these devices. These experiences related mainly to heart problems (e.g., pacemaker) and diabetes (e.g., insulin pump). Data showed that the responders would prefer a small, discreet and unobtrusive system with many people referring back to everyday objects. The majority (~85%) preferred the sensors to be non-invasive. However, many of this group (~95%) would wear an invasive device when life saving situations come into play. This topic was repeated in the closed-ended section, without fellow-up items and rephrased as implantable sensor. When the participants were asked where they would like to wear the device 85% answered external, 10.5% said internal and 4.5% left it blank. A median annual spend of £50 was found for the biotechnology that related to their own preference. A total of 62% of the people were willing to wear the device for more than 20 h a day. However, 37% expected it to have a battery life of more than 6 months. The placement of the technology on or in the body is expected to take less than 5 min (59% of the overall number of replies) and 35% of the respondents even think it should be less than 1 min (Bergman et al., 2012).


Wearable Sensors for Remote Health Monitoring

Wearable sensors comprise different types of flexible sensors that can be integrated into textile fiber, clothes, and elastic bands or directly attached to the human body. The sensors are capable of measuring physiological signs such as electrocardiogram (ECG), electromyogram (EMG), heart rate (HR), body temperature, electrodermal activity (EDA), arterial oxygen saturation (SpO2), blood pressure (BP) and respiration rate (RR). In addition, micro-electro-mechanical system (MEMS) based miniature motion sensors such as accelerometers, gyroscopes, and magnetic field sensors are widely used for measuring activity related signals. Invasive sensors: rectal thermometer; unsuited for continuous monitoring purposes. Axillary (armpit, thus non-invasive) temperature measurement is more convenient compared to the above-mentioned methods, but more lossy and inaccurate (Majumder, Mondal and Deen, 2017).


Measurement and Geometric Modelling of Human Spine Posture for Medical Rehabilitation Purposes Using a Wearable Monitoring System Based on Inertial Sensors

Inertial sensors have been used to measure spinal motion, making the data intuitive and user-friendly for the clinicians and patients who use the system. The data can be transformed into meaningful parameters such as rotation, flexion-extension and lateral bending. Theobald measured cervical range of motion with inertial sensors. It was proven that they are a viable and objective method for evaluating spine shapes (Voinea, Butnariu and Mogan, 2016).


State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes—The Need for Novel Non-Invasive Techniques

Currently, the SotA methods for measuring the muscle glycogen have been mainly invasive by means of needles (Elusive Gold Standard). The latest one has been developed by Bergström and is known to cause as little damage as possible, a high quality in minimal time restraints, can take multiple biopsies from one sample and allows measurement of other outcome variables (e.g. fibre typing, muscle damage, respiration, enzyme activity, etc). There have been no non-invasive techniques, except for histochemical measurement and MRS, developed yet for this problem (Greene, Louis, Korostynska and Mason, 2017).


Novel Wireless-Communicating Textiles Made from Multi-Material and Minimally-Invasive Fibers

Current textile used as clothing are able to sense, react and conduct electricity. The next-generation will be able to perform computational operations, thus getting a dynamical role. Active functionalities in a smart textile may include power generation or storage, human interface elements, bio-sensing devices, radio frequency (RF) emission/reception, various assistive technologies such as personal emergency awareness systems and response communication (Stepan, 2014). This article describes the operation of these textiles and the use of antennas (Gorgutsa et al., 2014).

Problem Statement

Extreme sporters find themselves in dangerous situations, and are hard to reach when they are in danger. Our combination of a drone and smartwear will monitor their health, warn them in time of potential dangers, and send help when necessary.

Users

Main users/target audience: Extreme Sporters.

Generalisable to: Space/Planetary Explorers, People who would start participating in extreme sports if it were safer.

Objectives

  • Creating smart sportswear with sensors to decide if there are any risks or problems
  • The smartwear must be able to at least monitor the vital functions: breathing, circulation, and consciousness.
  • The smartwear should be able to send preventive warnings
  • The smartwear needs a location tracker (GPS), and have a microphone and speaker to be able to contact medical personnel if necessary. The drone needs a GPS, microphone, speaker, and camera in order to be eyes on site for the medical personnel.
  • Time permitting a prototype and prototype app will be created.

Approach

After the literature study of week one, which lead to the concretising of the problem statement, users, objectives, and approach, the listed injuries and illnesses of week one will be turned into a list of the necessary sensors to measure the wearer. The aim of this is detecting such issues before they become a problem, and detecht them when they have become a problem. The problems using the most used sensors will be prioritised, and each week one of the most prevalent sensors will be researched, and implemented into a software and hardware prototype, and time permitting integrated into a mobile phone app. A smart flowchart will be created for the smartwear, which is to be used to detect potential and actual problems.

Week 2

Deliverables & Milestones

Deliverables:

  • New design plan
  • USE aspects

Milestones

  • Group decisions about new design
  • Research Mountaineers/Rock climbers
  • Research Sensors

Design Plan

Design Plan V3.png

Literature Research/State of the Art

User needs, Mountaineering / Rock climbing

Rock climbing injury rates and associated risk factors in a general climbing population (abstract only)

Self-reported measures research; 4.2 injuries per 1000 climbing hours, most injuries are in the realm of overuse (93%). Inflammatory tissue damages in fingers and wrists occurred most often. Older climbers have a lower risk of re-injuring something, whereas males have the highest chances.


Limits to human performance: elevated risks on high mountains

Many mountaineers are exposed to hypoxia, cold, and dehydration. The higher the mountain the lower the success rate and the higher the chance of death upon descending. The most important limiting factor in long term sustained human inhabitation of a certain location is barometric pressure. Decreased barometric pressure leads to decreased oxygen availability, which leads to physical stress. Hypoxia and dehydration exacerbate influence of cold temperatures. Wind chills the body even faster, which under these conditions makes temperatures drop another 25 degrees centigrade.

Research Sensors

Originally, the ePatch is a concept set out to be researched by students of the “Fontys Hogeschool Techniek & Logistiek”, commissioned by the company Yellow Factory situated in Hilversum. The incentive of the research was that Yellow Factory wanted to produce a product for people who build too much tension in their shoulders and neck, resulting in tension headaches. Their intention is to give the user a patch to wear on his/her shoulder, which detects when the muscle strain is too much and then gives either haptic or visual feedback to the user to relax his/her shoulder. This in order to prevent tension headaches that result from lasting muscle tension in the trapezius muscle (neck & shoulder). In order to measure the tension on the muscles, the ePatch uses an electromyogram (EMG) meter. (Costa, Keulen & van Rijsbergen, 2016))

Relevance for our objective: The concepts we can extrapolate from this research is the EMG meter patch, which should be attached around the fingers to measure tension in the fingers. As preventing injuries is more important than healing injuries, the patch should ideally be able to give some type of feedback to the wearer until the wearer has acknowledged to the system that the feedback has been received.

Research Communications

Communication

General purpose input/output (GPIO) pins can be used to transfer sensor information (McGrath, 2013). IEEE have developed the 1451 standard to standardise how smart systems should be embedded into larger systems. It does not specify the interfaces or define the physical connections, but USB, Ethernet and wireless 802.15.4, 802.11, and 6LoWPAN are definitely suitable (Lee, 2015). The biggest advantage of having serial connection instead of parallel is its simpler wiring and much less interaction (crosstalk) among conductors in the cable while having longer cabling (Rouse, 2011).

Serial Peripheral Interface (SPI):

  • Full duplex mode: synchronous sending and receiving
  • Allows communication between (digital) sensors but also between microcontroller and subsystem
  • SPI is loosely defined, so many different versions are available which means some firewall cracking sometimes.
  • Usually a four-wire serial communication bus, usually on a PCB, with one master device.
  • 100Mbps, short-ranged
  • Microwire: three-wire, signal-clock configuration, 625Kbps, short-ranged (EE Herald, 2006).
  • Main application: data stream transfer


TheI2Cbus

  • Facilitate low-bandwidth serial communication on same PCB
  • Multi-master mode over short distances
  • Two-wire bidirectional bus: one for clock signal, other for data
  • 100kbps - 400kbps - 3.4Mbps
  • 7-bit addresses => 128 slave devices possible
  • 8th bit for writing/reading identification


Standard Wired Interfaces

Serial port transmission: one bit at the time. Used by Ethernet, FireWire and USB. The DTE (data terminal equipment) and DCE (data circuit-terminating equipment) must agree on the communication standard: transmission speed (baud rate), number of bits per character, stop and parity framing bits (McGrath, 2013).

RS-232:

Used by peripheral devices: modems, mice printers +- 3 and +-15V for logical 1 and 0 to be immune against electromagnetic interference and voltage loss over long cables

Virtual Serial Bus:

software emulation of serial port Bluetooth, USB: Arduino Uno and Mega 2560 FTDI: newer Arduinos

RS-485:

inexpensive local networks and multidrop communication links large or short distances possible data lost when two devices talk at the same time

User Society and Enterprise aspects

User demands/needs Mountaineering / Rock climbing

Previously identified for extreme sports in general:

  • Experiencing raw, awe-inspiring nature
  • Proving one’s own skills to oneself
  • Acquiring mental health benefits
  • Being reached by First Aid in an easier and faster way (Especially important for mountaineering)

Specific needs of importance for Mountaineering/Rock climbing:

  • Heights:
    • Hypoxia/Hypercapnia → Blood sensor
    • Lightning (lethal injuries) → Weather report
    • Pulmonary oedema, cerebral oedema → Altimeter/Barometer monitor speed of ascension
    • Higher ultraviolet exposure → Sunblock textiles
  • Cold:
    • Hypothermia/Frostbite → Temperature sensors
    • Cardiovascular events → Heart rate monitor
    • Hallucinations → Earlier detection of hypothermia
    • Exacerbates if combined with hypoxia and/or dehydration and/or wind
    • Exercise induced asthma, Bronchial hyperreactivity → Microphones, heart rate
  • Overexertion & Overuse:
    • Dehydration/Hyponatremia → Galvanic skin response, Blood sensor
    • Inflammatory tissue damages to fingers and wrists → Tension sensors
    • Overuse injuries

Society's demands/needs:

  • Teaching people what their impact is on nature and the ecosystem
  • Having people try to combat environmental problems
  • Not paying too much for healthcare (keeping expensive incidents to a minimum)

Enterprise demands/needs:

  • Clear niche market to target and differentiate in.
  • Enterprises strive for profit → clear analysis whether it is worthwhile producing this product.
  • Keep competitive advantage, use SotA technology to distinguish oneself.
  • Increasing corporate social responsibility. Produce products that increase people’s safety to improve one’s brand image.

However, it is important to notice that in this particular situation, the User needs outweigh the Society and Enterprise needs (by a long shot).

USE Scenario's

  • A professional mountain climber is climbing a large snowy mountain. Even though he is well prepared, is well aware of the risks and has brought all relevant supplies, he cannot control all variables. When climbing, a blizzard hits, blocking all sight. His heart rate is lowering due to the cold, and in response he tries to hurry (in order to find shelter). In doing so, he overapplies tension to his fingers (severing nerves, which he is not aware of due to the cold). The tension sensors can sense this, and in combination with a lowered heart rate and decrease in skin temperature can deduce the fact that the hiker is likely in danger. It emits a distress signal to the nearby rescue post. A drone is dispatched. Using GPS tracking location, the drone can locate the hiker and guide the rescue squad there. The hiker, who in mean time has received a message that he should stop climbing and take some rest, can communicate through the drone. By preventively alarming the rescue post, the hiker can be brought to the hospital and treat his hands. With a bit of luck, he might just regain feeling in his fingers.
  • A young athlete is seeking for a new way to get a thrill. He decides to go mountain climbing. However, he is not that experienced yet, and is not fully aware of all dangers. When starting, he rushes up the mountain in a streak of adrenaline. However, he quickly feels dizzy and light-headed. The electromagnetic skin patch sensors in his suit detect a change in intracranial fluid. In combination with a lowered heart rate, the smart-tech warns the athlete that he probably is deprived from oxygen. A drone is dispatched with extra oxygen to get the athlete back on track.
  • A hiker is lost in the snowy mountain tops. He starts to panic and realizes he is running out of food supplies. He has no cell phone connection and does not know what to do. Using his SMART-watch, he emits a distress beacon that is picked up by the rescue post. The drone scouts the area and finds the shortest path to the hiker. The drone can then either instruct the hiker back to the road or lead the rescue squad to the hiker.
  • A hiker is suddenly feeling nauseous and has no idea what is happening. He uses his smart suit to check his vital functions. The non-invasive sensors (e.g. heart rate, temperature, etc.) do not detect any dangers. The suit then turns to invasive sensors, and checks the blood composition. The results return an elevated level of a certain toxin. Apparently, a few hours ago, the hiker mistook some toxic berries for regular berries. The suit reports this, which enables the hiker to call upon a drone and after a while, the drone arrives with an antidote. The hiker administers the antidote, using instructions from the medic (who communicates through the drone). The hiker is then saved from food poisoning and can safely return home.
  • After a rough day, a hiker goes to sleep. That night, his toes get too cold, and the system detects a danger to frostbite. The tech emits alarms to the hiker. 1) The hiker wakes up and can prevent frostbite in time. 2) The hiker does not wake up and the next morning wakes up to find out his toes are affected by frostbite. Being a professional hiker, he knows that rewarming his toes only increases the risk of tissue damage (since he is still exposed to the cold and refreezing could occur). Luckily, the smart tech already detected a drop in temperature and allerted the medics. The medics get there in time to bring the hiker home and treat his foot before any permanent damage is caused.

Taking several scenarios into account. The use of a SMART suit (in combination with a drone) could drastically increase healthcare efficiency, and prevent pretty horrible situations. The SotA in this tech does not fully rely on the use of a drone, but is more centered around the diagnostic ability of the suit as well as the preventive warnings this suit emits.

Week 3

Deliverables & Milestones

Deliverables

  • Choice of Sensors
  • Choice of Communication types
  • Choice of Processor

Milestones

  • Research Communications
  • Research Sensors
  • Research Processors

Literature Research/State of the Art

Research Sensors

Temperature Sensor

Ideal and State of the Art: The current wearable electronic devices often lack the sensing accuracy due to movement artifacts because of their rigid en bulky size. It is hard to adapt to the soft and deformable skin. They do provide high performance for signal treatment, communication and power management (Magno, 2016). Contrary to those devices, “skin-like” or “epidermal” sensors exist, which have unparalleled accuracy and precision thanks to their thickness and compliant mechanics. The contact with the skin is therefore robust and intimate. The downside of this sensor is that continuous and long time monitoring is currently only possible with wired connections. This would mean that wireless connections only give “on-demand” measurements. Magno et al. (2016) have proposed a wireless transmission and energy harvesting solution working on solar energy. In their conclusion, they found that their setup consumes 2 mW when accurately sampling temperature. This was functional under and self-sustaining under indoor light-conditions, so they proposed another solution with the help of thermal harvesting of the human body itself for further research, to measure the attainability of such a self-sufficient power harvesting method.

Affordable and Realistic for a Prototype: A wireless body temperature sensor system was created, using relatively affordable materials as to make it accessible to financially challenged countries such as Malaysia. It’s main components are an LM35, and uses an XBee and Arduino with WLAN shield to wirelessly connect to the internet. It reportedly has a 0.25 degrees centigrade accuracy when used to measure temperature on a subjects hands. According to the experimenters this is comparable to a commercial thermometer. This type of technology is both wireless and cheap, with an accuracy that could potentially be improved when measuring a more suitable spot instead of hands.


Galvanic Skin Response Sensor

Ideal and State of the Art: A GSR sensor system was designed to be used for continuous measurements from the back of the body, designed to be flexible and have on-board signal processing. The measurement results showed a high correlation with the utilised reference system of standard fingertip electrodes, and when graphs of the reference signal and the new device’s signal were compared, the characteristics were similar enough to deem the device sensitive enough. The design was made flexible by utilising a “foam-type conductive material” so it would mould itself to the shape of the body it is applied to. The attachment system is designed to be easily attachable and detachable to several types of bodywear. (Kim, Kwon, Seo, and Park, 2014)

Affordable and Realistic for a Prototype: Whichever Galvanic Skin Response sensor the teachers are able to provide us with.


Heart Rate Sensor

A small scale heart rate monitor was created using a custom made flexible pressure sensor and an analog anti-interference circuit. The sensor’s response was linear, with a high sensitivity of 13.4 /kPa. The interference circuit removes noise caused by body movements, and when also taking the sensor’s high flexibility into account this sensor proves to be a comfortable long term heart-rate monitoring solution. The system was compared against other currently commercially available solutions and proved to have an equivalent capability. (Shu, Li, Wang, Mi, Li, and Ren, 2015)


Blood Parameters One option for measuring blood parameters and other parameters, like pulse rate, arterial blood oxygen saturation and volume changes can be done with the optical technique called Photoplethysmography (PGG). It uses a clip which contains a light source and a detector on opposite sides to detect the cardiovascular pulse wave that propagates through the body. The PPG waves can be described as containing a direct current (DC) component due to venous blood and an alternating current (AC) component due to blood volume changes in the arteries. The principle of the estimation of pathophysiological parameters using PGG is based on differential absorption of near-infrared radiation (NIR) by different chromophores present in the blood of capillaries, when the subject’s finger is exposed to NIR radiation.


Respiration Rate Sensor

As Koch & Dietzel have shown in their research (Koch & Dietzel, 2016), it is entirely possible to produce an array of sensors that can reliably determine respiration rate by measuring body deformations. The sensors in the array are conductive, and deformation of the material changes the conductivity of the material slightly. By placing several sensors in an array, using different directions, a map can be drawn based of the conductivity of each individual sensor. After calibration, this conductivity map can be translated to certain deformation patterns, as the conductivity is determined by the thickness and the deformation radius of the material.


Barometer

Air pressure sensors have developed so far that they can be implemented in smartphones. These sensors measure the atmospheric tides, that are produced by the absorption of solar radiation in water vapor or ozone. The sensors measure this to determine the atmospheric pressure. (Price et al., 2018) There is little holding us back from implementing the same sensors in our smart suit. Sensors at this point are specific enough to even determine what floor a person is walking on. By using sensors that measure changes in atmospheric pressure, the barometer can accurately predict the height of the person (since pressure and haight are strongly correlated). (Ichikari et al., 2015) Currently, the data collected is being transmitted via WiFi. A point of improvement is finding a way to keep the hiker up to date about his height without having to use WiFi.


GPS

Global Positioning System is a method of tracking one’s movement via satelite localization. This space-based system uses the connection between a transmitter (e.g. a smartphone) and a satellite to determine the approximate location and time. This technology proves effective as long as the line of sight to GPS satellites is unobstructed (e.g. not underground). Therefore, GPS tracking is suitable to implement in our suit, as mountains are high and thus clearly detectable by GPS satellites. GPS tracking uses little energy, and can be sustained easily by implementing a solar cell in the smart suit. (Persson, M., Karlsson, D., 2018)

Research Communications

Short- and Medium-Range Standards for Wireless Communication

Four key short-range, low-power, wireless communication standards; Bluetooth (IEEE 802.15.1) (Eliasson et al., 2008), UWB (IEEE 802.15.3), ZigBee (IEEE 802.15.4), and Wi-Fi (IEEE 802.11), predominate in the sensor application domain. They all have different data throughputs and ranges (Lee et al., 2007), as can be seen in Figure 1. Bluetooth has been heavily adopted for body-worn applications; Zigbee or 802.15.4 is used for indoor and outdoor multinode network applications; and UWB supports a variety of applications, ranging from implantable sensors (Yuan et al., 2011) to high-precision geolocation determination (Win et al., 2009). Wi-Fi is usually applied in ambient applications where longer ranges, higher data rates, and immunity to signal attenuation in high blockage environments are required. Table 1 shows all advantages and disadvantages of the four mentioned standards.

Since wireless technology is increasing in the health and sport section, the need for a good battery life is required. Therefore, Bluetooth Smart has been developed. It allows Bluetooth Smart users to connect devices and using significantly less battery life. Since Bluetooth has been integrated in many devices, especially in portable devices, an upgrade to Bluetooth Smart can be done easily.

Another known protocol would be 6LOWPAN driven by low power devices, able to join the cause at low data rates and duty cycles. 6LOWPAN is more like a cloud (Olsson, 2014). It is in need of a wireless internet connection (IPv6) in order to work.

In 2012, the IEEE announced the 802.15.6-2012 protocol for short-range, wireless communications designed for in proximity to or inside a human body with data rates up to 10Mbps. Compliant devices use very low power to minimise the specific absorption rate (SAR) into the body and to increase the battery life. The standard supports quality of service (QoS) and strong security, which include EEG, EKG/ECG, temperature, heart rate, oxygen, and blood pressure.

1-Wire

  • serial protocol: single data line and ground
  • 1 master, several slaves
  • Slaves have unique, unalterable, factory-programmed, 64-bit ID with 8-bit family code
  • 2.8 to 5.25V, parasitic supply to the 1-Wire bus
  • half-duplex bidirectional communication
  • Does not seem applicable to our project.


Taking all available choices into consideration, Bluetooth Smart seems to be the most applicable. Zigbee could also be an implementation.

Table 1: Advantages and disadvantages of the four main communication standards (McGrath et al, 2013).

Commstandards1.jpg

Graph1.JPG

Figure 1: Key protocols for wireless applications (McGrath et al, 2013).

Research Processors

CPU Options
Name: SimpleLink CC264R2F ESP32 AMD Sempron Embedded Kinetis KL28 Arduino Uno/ATmega328
Manufacturer: Texas Instruments Espressif Systems AMD NXP Qualcomm Atmel
Link: http://www.ti.com/product/CC2640R2F/description https://esp32.net (unofficial site) https://www.espressif.com/en/products/hardware/esp32/resources https://www.amd.com/en-us/products/processors/desktop/sempron-cpu# https://www.nxp.com/products/processors-and-microcontrollers/arm-based-processors-and-mcus/kinetis-cortex-m-mcus/l-seriesultra-low-powerm0-plus/kinetis-kl8x-72-96-mhz-secure-ultra-low-power-microcontrollers-mcus-based-on-arm-cortex-m0-plus-core:KL8x ,

https://www.nxp.com/docs/en/data-sheet/MKL28Z512Vxx7.pdf

http://docs-asia.electrocomponents.com/webdocs/0e8b/0900766b80e8ba21.pdf

http://ww1.microchip.com/downloads/en/DeviceDoc/doc7799.pdf

Instruction Set: ARM Xtensia ISA x86-64 ARM RISC
Clock speed: 48 Mhz 240 Mhz 3.2 GHz 96 Mhz 8-16 Mhz
RAM: 2 kb 520kb Requires external RAM 96 kb 1 kb
Power Consumption 5.9 mA (Active)

1.1 μA (Standby)

20-50mA (Not including Bluetooth) 25w (Not found in amps) 9.6 - 12.8 mA 13-21 mA
Size: 2.7 x 2.7 mm – 7 x 7mm (Larger option has more pins and a lower minimal order size) 7 x 7mm (48 pins, 10-13 GIPO’s) Not found, likely to be large. 8x8mm – 14x14mm(82 GIPOS) 5 x 5 mm - 7 x 7 mm
Price (Estimate): €3.57 (up to 50% discount when buying 1000+ units) €2.62 €207.49 €2.33 €1.82
Features: Bluetooth,

Dedicated subchips for AES and RNG

Bluetooth, wifi,

Dedicated subchips for AES, RSA, SHA and RNG

Fast enough to power screen,

Will not function below 0 degrees embedded cooling

Dedicated TRNG generator + accelerators for DES, 3DES, AES, MD5, SHA-1 and SHA256. -
Notes: - Currently in a team member's possession. - Timer inaccurate in extreme temperatures,

flexible input voltage. Very detailed specifications.

Only multiples of 250 available, but an Arduino utilising this chip is currently in a team member's possession.

Statistics about Mountaineers/Rockclimbers

  • 47.2 million people have gone trekking (hiking/backpacking) in the united states alone from spring 2016 to spring 2017. (SFIA)
  • “Around 211,000 people (aged 14+, living in England) go climbing or hill walking at least once a month and 84,000 take part at least once a week.” (Gardner, 2015)
  • “25 million people are climbing regularly” (International Federation of Sport Climbing)
  • “Mountain biking has an estimated 8.6 million participants, making it the second-most popular extreme sport” (Jones, 2008)
  • 2.53 million people have gone climbing (traditional/ice/mountaineering) in 2017 in the United States alone. (SFIA)
  • The Royal Dutch Climbing and Mountaineering Federation (NKBV) has +- 59.000 members in 2015 and are growing every year. (NKBV, 2015)
    • 62% male vs 38% female
    • 14% avid climbers, 31% alpinist, 53% mountaineers, 2% other activities

Week 4

Deliverables & Milestones

Deliverables:

  • Finishing up smartwear research

Milestones:

  • Wiring Choices Research
  • Battery Choices Research
  • Communication Choice Research
  • Start Energy Harvesting Methods Research


Literature Research/State of the Art

Sensors Research

The reason we choose for some SotA sensors that are on the market is because we want our suit to be realistic. There are undoubtedly newer sensors in development, yet these are not yet being manufactured. There is a difference between developing a new technology and enabling that technology to actually have an impact on the current society. Not all SotA sensors that are being developed right now will ever be implemented in devices, because the necessary details are kept secret.


GPS

The sensor we will implement in our suit is the ZOE-M8B GNSS tracking chip. This sensor, developed by uBlox is precise up to 4 meters and can track movement up to 0,4 m/s and 2 degrees (for the direction) accuracy. It has a special ultra-low power mode called Super-E, which reduces the power consumption to12 mW. (uBlox, 2018) This solves the largest issue of most GPS devices: their massive power consumption.


Barometer

The sensor we will implement in our suit is the BMP280 Barometric Pressure Sensor, manufactured by Bosch Sensortech. (Bosch SensorTech, 2018)This sensor is only a few millimeters large and extremely low-powered (2,7μA power consumption on average). The sensor is accurate up to 0.12 hPa and functions within a range of -40 degrees to 85 degrees (which should suffice for the mountaineering climate).

Blood Composition

After conducting extensive research, we have elected to use the current SotA OCM1 sensor from Taiwan Biophotonics Co. This sensor enables a blood oxygen measurement with only a 3% accuracy range and measures the patient’s heart rate with only 4 bpm variation (TBPC, s.d.). The sensor is relatively low-power consuming and can be implemented in the fingertips or wrists of the suit (where it is most accurate). For our application, the wrist seems the most plausible solution.


Sensor Details Overview (Not all details were available for all sensors)
Name/Model: Website: Pins (Voltage Range) Size Accuracy and/or Precision Power Consumption Price Location on Suit
Texas Instruments LM35A (Temperature Sensor) https://www.hackerstore.nl/Artikel/18 V input = 4 V to 30 V

Ground V out = 10 mV per degree Centigrade, linear by approximation

4.699 mm × 4.699 mm 0.5°C Ensured Accuracy (at 25°C)

typical accuracies of ±¼°C at room temperature and ±¾°C over a full −55°C to 150°C temperature range

60 μA €1,70 Our choice; armpits?
BMP280

Barometric Pressure Sensor (Also usable for temperature)

fhttps://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-19.pdf I2C protocol (8 pin)

8 pins: specifics op pagina 35 van document VDD tussen 1.71V en 3.6V VDDIO tussen 1.2 en 3.6V

2.0 mm x 2.5 mm x 0.95 mm ±0.12 hPa (voor Pressure)

±0..5 Celsius (temperatuur)

range van -40 tot 85 graden

2.74 μA gemiddeld

4.16 μA max

€2,86 Needs to be in contact with the air; shoulder?
ZOE-M8B GNSS tracking chip https://www.u-blox.com/sites/default/files/ZOE-M8B_DataSheet_%28UBX-17035164%29.pdf I2C Compliant

51 pins: specifics on pagina 16/17

Table with voltage range on pagina 18

4.5 mm x 4.5 mm x 1.0 mm In power saving mode:

Speed: 0.4 m/s Heading: 2 degrees Location: 4.0 m

12 mW in Super-E mode €10,90 A location promoting easy connection with a satellite; shoulder?
Autonomous smartwatch with flexible sensors for accurate and continuous mapping of skin temperature (Magno et al., 2016) https://ieeexplore.ieee.org/document/7527239/ unreported, system sends processed data

Each sensor is electrically and individually connected to the smartwatch by a flexible anisotropic conductive film which brings every temperature sensors output to an ADC microcontroller’s pin

The dimensions of the rigid board used for the assembly are 45mm x 57mm and each solar cell has dimensions of 35mm x 14mm for a total area 39cm2.

(MSP430FR5969, Texas Instruments) with an internal ADC, energy harvesting circuits (build around the BQ25570, Texas Instrument), and NFC chip (M24LR16E-R, STMicroelectronics) for wireless communication

Wristband delivers a maximum current of 100 µA @ 1.9 V in indoor conditions (i.e. 300 – 500 LUX) and a maximum current of 15 mA @ 1.6 V under the sunlight (system uses it’s own rechargable battery and solar panels, these stats are enough to keep the system sels sustaining indoords.) Order of a few µW in sleep mode, 2mW in acquisition mode, between 2.8 and 3.6 mW when sending data

40mAh lithium rechargeable battery

Unreported The article uses wrists, though presumably other locations would work too.
Highly wearable galvanic skin response sensor using flexible and conductive polymer foam (Kim, Kwon, SEO and Park, 2014) https://ieeexplore.ieee.org/document/6945148/ "Designed to measure skin conductance levels from 0 to 50 µS. A 3 Hz low pass filter is included in the analog signal processing part. The filtered analog signal is followed by analog-to-digital conversion in a microcontroller (MCU). A digitized signal of 10-bit resolution is wirelessly transmitted through a Bluetooth interface." 38.5mm x 42.5mm GalvanicAccuracy.JPG Unreported Unreported Back
A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and an Anti-Interference Post Processing Circuit (Shu, Wang, Mi, Li, and Ren, 2015) http://www.mdpi.com/1424-8220/15/2/3224/htm The device responds linearly to the external pressure with the sensitivity around 13.4 kPa−1

HeartRateOutput.JPG

15 mm × 30 mm (size of the sensing part) HeartRateAccuracy.JPG Unreported Artery location (arm, neck, leg)
OCM1 oximetric sensor http://www.tbpchc.com/eng/medical.php?gid=13 1,8 tot 3,6V,

I2C Compatible

8.0mm x 11.4mm x 2.6mm Heart rate: 3bpm variation for a heartrate between 40 en 240 bp (therefore unsuitable during serious hypothermia)

Oxygen: 3% off for an oxygenpercentage between 70 en 100% (therefore unusable in extreme cases as well)

60 mW Unreported Wrist or finger
Wiring Choices Research

Currently Available

Adafruit, a company founded in 2005 by MIT graduate Limor Fried with the aim of creating the best online electronics education site and best designed products store for all ages and skill levels. This store also caters to wearable electronics, specifically smart textile solutions (Adafruit Industries, n.d.).

Adafruit's Smart textiles options (mostly wiring, some sensors)
Name: Size: Price Resistivity Notes
Stainless Thin Conductive Thread - 2 ply 23 meters $5.95 16 Ohms per 0.3 meters

Drives components using under 50 mA

Doesn’t oxidise, like stiff sewing thread. (Safe to wash)
Stainless Medium Conductive Thread - 3 ply 18 meters $6.95 10 Ohms per 0.3 meters

Drives components using under 100 mA

Doesn’t oxidise, like stiff sewing thread. (Safe to wash)
Stainless Steel Conductive Ribbon 5 mm x 1 meter $24.95 2.6 Ohms per 0.3 meters

Drives components using under 500 mA

Doesn’t oxidise, thin, strong, smooth, flexible like textile ribbon. (Safe to wash)
Stainless Steel Conductive Ribbon 17 mm x 1 meter $29.95 1.2 Ohms per 0.3 meters

Drives components using under 1000 mA

Doesn’t oxidise, thin, strong, smooth, flexible like textile ribbon. (Safe to wash)
Pressure-Sensitive Conductive Sheet (Velostat/Linqstat) 28 cm x 28 cm x 0.1 mm $3.95 Volume Resistivity : <500 ohm-cm

Surface Resistivity : < 31,000 ohms/sq.cm

Pressure sensitive, squeezing reduces resistance.

Heat sealable

Conductive Rubber Cord Stretch Sensor 2 mm diameter, 1 meter long $9.95 350 Ohms unstretched, resistance increases by stretching Maximum stretch: 50 - 70% longer than resting length. Takes minutes to revert to original length. Not an exactly linear sensor, resistance may vary.
Conductive Hook & Loop Tape 7.5 cm $7.50 Hook: 1.8 Ohm per sq, Loop: 1.4 Ohm per sq, 0.8 Ohm through mated closure Silver coating, can oxidise.
Flex PCB Material - Pyralux 15 cm x 15 cm $8.95 Unreported Can be cut with scissors or etched with a PCB etching system. Doesn’t crack as easily as copper tape.
Eeonyx Stretchy Variable Resistance Sensor Fabric 33 cm x 30 cm x 0.5 mm $24.95 129 KOhm / square cm surface resistivity in rest, halves when stretched Bidirectionally stretchy. Can be washed.
Knit Jersey Conductive Fabric 20 cm x 20 cm $9.95 46 Ohms per 0.3 m in stretchy direction, 460 Ohms per 0.3 m in less stretchy direction. Uses silver yarn, can oxidise. Dry clean.
Knit Conductive Fabric 20 cm x 20 cm $9.95 1 Ohm per 0.3 m Uses silver yarn, can oxidise. Dry clean. Bit stretchy, not much.
Woven Conductive Fabric 20 cm x 20 cm $4.95 1 Ohm per 0.3 m Users copper & Nickel plated nylon. Dry clean. Does not stretch.


State of the Art

As we were considering wires, it dawned on us that extreme sporters in the mountains are prone to wear and tear, especially when it comes to mountain climbers. It is therefore useful for our wiring to be sturdy enough to deal with these conditions, or possibly self-repair? Luckily, Sun et al. (2014) have researched self-healable conducting wires. In Sun et al. (2014), they have tested wrapping carbon nanotubes (or similarly conducting material like Ag-nanowires) around self-healing polymer. The self-healing polymer amends breakage after approximately 20 seconds, making use of Van der Waals forces without greatly impacting the conductive properties of the wrapped carbon nanotubes. Despite Van der Waals forces being very weak, the number-density range of 1010-1011 cm-2 of the carbon nanotubes produces a high force. Tensile strength after breaking was preserved at around 80% (averaged over aligned carbon nanotube sheet, silver-nanowire network and carbon nanotube network), with 92% as a maximum. The resistance of the different wires has also been tested, with the carbon nanotube sheet being the closest to original resistance at an approximately 120% from original. It is however debatable if these wires are sufficient for our use-case, in which the distance of the wire can be separated enough for the Van der Waals forces to lose their strength. For this reason, we have chosen to leave this option on the table, but decided to not currently utilise it.

Communication Choice Research and Tentative Communications Decisions

Long-range communication

Communication to the base station:

As is widely known, communication to the base station (which in turn communicates with other stations, to the destination) can be done in several ways. One could think of phone calls, text messaging and mobile internet. What is needed to have this communication is a SIM (Subscriber Identification Module) card. As the name suggests, communication to a (base) station is not free. Stations are owned by companies which we pay to make use of. Thus, in the proposal, the user has to have access to the base station using a SIM card. As it is common to already own one (103 customers out of 100 people owning cell phones (EC, 2007), thus likely to have a SIM card in it), our proposal will use this fact to be sure that the wearer of our design has access to the stations.

It is becoming a standard to have a working network everywhere, which means that more stations have to be build to supply the increasing demand. This also means that stations are being built at the most difficult places thought of, just in mountains. Still, this has not been fully realised so alternatives are needed. One could think of Walkies, GPS trackers and satellite phones to communicate with emergency lines. This backup should always be present as well. Our prototype will still work with mobile phone communication, but we keep in mind that not every corner has a working network. For now, we assume that the sporter has active connections at all times, thus the use of SIM cards suffice. When further implemented, alternatives can be programmed and developed using the same codes and algorithms to reach the base station.


Alarming (Deploying Drones):

Considering the fact that extreme sporters expose themselves to extreme conditions, often difficult to reach for humans, drones can be deployed when the situation is not life-threatening (yet) (Examples such as dehydration situations come to mind.) In any way, the drone would have to be alarmed in some way through the device. Considering the assumption that everyone owns a working phone with SIM card, distress signals can be send to the (base) stations which would then employ the drone with the desired outcome. Different options should be possible. The user should be at the highest level of authority at all times. This would mean that the user can always send distress signals themselves, cancel (incorrect) signals, etc. However, when the user is not capable of doing this him/herself (e.g. when the user has fainted), the product should be able to detect this and send a signal autonomously. A working network is here assumed to always be present.

Cloud Storage:

Nowadays, everything is being stored on some sort of cloud. This cloud storage is increasing, so our design should also consider cloud storage. If the product would come to the market, the enterprise would need a storage place. This is out of the scope and will not be considered any further.


Base Architecture

BaseArch.JPG

  • Every sensors at least 10 cm away from the nearest MCU (microcontroller unit) gets its own MCU. If the nearest MCU has no free pins, it will also get its own MCU.
  • All MCUs will store data from its sensors, and transmit only when asked for by the master.
  • Any non-sensor subsystems, like the long distance communication, will also have their own MCU’s.
  • Use the CC264R2F since it is extremely small (2x2mm) and can be attached to pretty much any sensor without significantly increasing size. It also has an extremely low power consumption and built-in bluetooth. Exceptions can be made whenever practical.
  • Every MCU gets a ID, starting from 1 to 128. When the main controller loses connection to a MCU, the MCU with the lowest ID still connected to the same subnetwork becomes the master of the subnetwork
    • If a MCU has not received a signal from the master before some time out (even signals addressed to other MCU’s), it will conclude the connection to the master must have broken
    • After signalling to all other sensors on the network that it has taken over, the new master will open a Bluetooth connection to check if the master is actually dead or that a wire is simply broken. If a Bluetooth connection can be made, all data from other sensors on the same network (if any) will be sent to the master.
    • A master or submaster, upon detecting a child-MCU is not responding, will switch on bluetooth for some fixed time to try and attempt a bluetooth connection in case of wire failure.
    • If a child-MCU is already in a subnetwork before it loses connection, will not attempt to reconnect with the master of the subnetwork, but rather whatever master has the lowest ID.
  • Any sensors with a built-in MCU which is not programmable will be given the highest IDs, as they can not take over the network.
    • These sensors will simply shut down when the connection breaks and no other master is in the same network
    • We could possibly attach an extra MCU even to sensors with a built-in MCU if we want even more robustness
  • We should make an effort to find wire locations that will be more likely to have broken wires, and use this to assign MCU IDs more effectively to make sure all sensors will stay connected.


Advantages:

  • Use less pins, so we can use sensors that require a lot of pins (I2C requires only one input and one output pin per node)
    • Use less wires as well, the I2C can run as a single wire to some hub of many sensors, then split
  • A lot of the sensors on our current sensor list have built in MCU’s that are already I2C compatible, so we can connect them to the network for free
  • Allows transfer of data digitally, so no analog inaccuracies.
  • Allows every chip to record data and send it faster in batches, thus freeing up processing power on the main chip to do other computations

Allow use of separate power supplies, so we can use the cool ambient power systems for the relevant sensors only

  • The I2C multi-master system allows a different microcontroller to take over as “master” when the main one breaks, so it can still function and record data when any one MCU is functional
  • Since the SimpleLink CC264R2F has Bluetooth, we can switch communication to Bluetooth in case a wire breaks.
  • Easy and cool enough to demonstrate for prototype


Disadvantages:

  • More power consumption, every MCU needs to be powered
    • If we switch to Bluetooth, even more power needs to be used
  • More work: Every chip has to be programmed
  • Since the main controller can only poll one sensor at a time, it may react a bit slower
  • I2C supports a maximum of 128 MCU’s on a network
  • Even the small chip is still a solid, fragile, hot block that makes the suit less comfortable, especially if we add some padding for protection
  • We probably cannot reprogram the built in MCUs on many of the sensors, so we cannot actually use a lot of the cool features listed above for those sensors.
  • In order to use switch the master node, the I2C connection must be to pins that can be switched to be either input or output. This limits the choice for pins.


Alternative Proposal:

  • Only use I2C for sensors that require too many pins otherwise
    • Saves work
  • Connect every sensor via long wires to the master MCU with analog signals
    • Noise on long analog signals, should not be much on the scale of the suit though
    • Every sensor needs at least two wires directly to the master MCU, so many wires to areas far from the master MCU that have a lot of sensors


For the Prototype:

We can make a basic demonstration using the two ESP32s, since they have Bluetooth capabilities. We can show that after disconnecting a wire, it can connect via Bluetooth, and that even if the main controller is switched off, we can still record data and retrieve it when the main controller is switched back on.

Reasoning behind processor choice:

For the end-product central chips: ESP32 has been chosen because it has the highest processing-power to cost ratio, while having useful features like Bluetooth and an “ultra low power” mode. Furthermore, it contains 48 pins which should be enough. Also, it is already owned by one of the members. The main disadvantage is the high peak-power consumption and its size. For the end-prodcut per-sensor chips: SimpleLink has been chosen. Its main advantage is that it has extremely small variants, allowing the user to easily glue it to sensors without taking significant extra space. The power consumption is also extremely low. It also contains Bluetooth. For the prototype chips: The ESP32 has been chosen again. This is due to the fact that good development boards are available, and they are cheap. It is also useful to use the same chip twice to ensure maximum code reuse.


Reasoning behind the choice for I2C

There are several reasons why SPI was not chosen. The main advantage of I2C is that it is natively supported by the greatest number of our sensors. Moreover, SPI needs four (or three when using microwire) wires while I2C only needs two. It is thus easier to implement compared to SPI. As we want to use as less wires and space for the prototype, fitting everything onto one PCB and processor would be the most ideal case. Furthermore, I2C facilitates low-bandwidth serial communication on the same PCB, which means that more sensors can be soldered to one single PCB, which makes the prototype less bulky. Also, SPI is loosely defined, meaning no standard version is available, thus making firewall cracking easier. The main disadvantage is that it is slow: 400kb/s, over than 10x slower than SPI. This speed needs to be divided over all sensors since they are all connected to the same communication line. What would make SPI a better choice as well is its ability to synchronously send and receive (full duplex mode). Because of these reasons, when actually implementing the design, it could be possible to change to SPI because of its speed, synchronisation and greater range of use. But as has been motivated, I2C has been chosen for the prototype.

Week 5

Deliverables & Milestones

Deliverables

  • Health Warnings Algorithm (start)
  • Design Plan (start)
  • Drone Research (Start)


Milestones

  • New Heart Rate Sensor for proof of concept
  • Battery Choice Research
  • Energy Harvesting Options Research

Literature Research/State of the Art

Battery Research

Lithium-polymer batteries

LiPo batteries are flexible and make use of a dry polymer to which an elektrolyt gel has been added (Replace Direct, 2018). These batteries are only 4mm thick and can be charged entirely within an hour. Some important features are the fact that it is flexible, it has a high cell voltage (3,7V) and it has a high energy and power density.Unfortunately, these batteries are not fit to use in extreme weather, so the only viable option here is to keep them close to the human body. At temperatures above 70 degrees, the battey can expand and get damaged, for example. An example of such batteries is the Apple iPhone 5s accu, with a capacity of 1500mAh and a price of 19,50 euro (123Accu, 2018).


Hermes Lithium-Metal battery

This battery, developed by Solid Energy, is the lightest rechargeable battery on earth.The battery is approximately 6 cm high, 4 cm broad and 6 mm thick. It functions under 3.8V and has a capacity of 3,4 Ah (at 25 degrees). It is flexible and extremely high-density. This battery is currently used in for example drone applications and can withstand temperatures up to 45 degrees, with a minimum of 0 degrees while charging and -20 degrees while discharging. (Solid Energy, s.d.)


GMB Low temperature LiPo battery

This battery uses the same technology as the first described. However, this battery can perform at temperatures from -40 to 45 degrees. It has a capacity of 40 Ah and a nominal voltage of 25.9V. This might be the best solution for our design. (GMB, 2015).

Updated Sensors Research
Sensor Details Overview (Not all details were available for all sensors)
Name/Model: Website: Pins (Voltage Range) Size Accuracy and/or Precision Power Consumption Price Location on Suit Needs an extra Micro Controller Unit?
Texas Instruments LM35A (Temperature Sensor) https://www.hackerstore.nl/Artikel/18 V input = 4 V to 30 V

Ground V out = 10 mV per degree Centigrade, linear by approximation

4.699 mm × 4.699 mm 0.5°C Ensured Accuracy (at 25°C)

typical accuracies of ±¼°C at room temperature and ±¾°C over a full −55°C to 150°C temperature range

60 μA €1,70 Our choice; armpits? Yes
BMP280

Barometric Pressure Sensor (Also usable for temperature)

fhttps://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-19.pdf I2C protocol (8 pin)

8 pins: specifics op pagina 35 van document VDD tussen 1.71V en 3.6V VDDIO tussen 1.2 en 3.6V

2.0 mm x 2.5 mm x 0.95 mm ±0.12 hPa (voor Pressure)

±0..5 Celsius (temperatuur)

range van -40 tot 85 graden

2.74 μA gemiddeld

4.16 μA max

€2,86 Needs to be in contact with the air; side No
AD8232 module (heartbeat sensor) http://www.analog.com/media/en/technical-documentation/data-sheets/AD8232.pdf Operating voltage: 3.3V

Single supply operation: 2.0 - 3.5V

4 mm x 4 mm See datasheet 170 μA From €12,60 Chest No
ZOE-M8B GNSS tracking chip https://www.u-blox.com/sites/default/files/ZOE-M8B_DataSheet_%28UBX-17035164%29.pdf I2C Compliant

51 pins: specifics on pagina 16/17

Table with voltage range on pagina 18

4.5 mm x 4.5 mm x 1.0 mm In power saving mode:

Speed: 0.4 m/s Heading: 2 degrees Location: 4.0 m

12 mW in Super-E mode €10,90 A location promoting easy connection with a satellite; shoulder? No
Autonomous smartwatch with flexible sensors for accurate and continuous mapping of skin temperature (Magno et al., 2016) https://ieeexplore.ieee.org/document/7527239/ unreported, system sends processed data

Each sensor is electrically and individually connected to the smartwatch by a flexible anisotropic conductive film which brings every temperature sensors output to an ADC microcontroller’s pin

The dimensions of the rigid board used for the assembly are 45mm x 57mm and each solar cell has dimensions of 35mm x 14mm for a total area 39cm2.

(MSP430FR5969, Texas Instruments) with an internal ADC, energy harvesting circuits (build around the BQ25570, Texas Instrument), and NFC chip (M24LR16E-R, STMicroelectronics) for wireless communication

Wristband delivers a maximum current of 100 µA @ 1.9 V in indoor conditions (i.e. 300 – 500 LUX) and a maximum current of 15 mA @ 1.6 V under the sunlight (system uses it’s own rechargable battery and solar panels, these stats are enough to keep the system sels sustaining indoords.) Order of a few µW in sleep mode, 2mW in acquisition mode, between 2.8 and 3.6 mW when sending data

40mAh lithium rechargeable battery

Unreported The article uses wrists, though presumably other locations would work too. No
Highly wearable galvanic skin response sensor using flexible and conductive polymer foam (Kim, Kwon, SEO and Park, 2014) https://ieeexplore.ieee.org/document/6945148/ "Designed to measure skin conductance levels from 0 to 50 µS. A 3 Hz low pass filter is included in the analog signal processing part. The filtered analog signal is followed by analog-to-digital conversion in a microcontroller (MCU). A digitized signal of 10-bit resolution is wirelessly transmitted through a Bluetooth interface." Only communicates via bluetooth, but we can probably strip out the microcontroller 38.5mm x 42.5mm GalvanicAccuracy.JPG Designed to measure skin conductance levels from 0 to 50 µS. A 3 Hz low pass filter is included in the analog signal processing part. The filtered analog signal is followed by analog-to-digital conversion in a microcontroller (MCU). A digitized signal of 10-bit resolution is wirelessly transmitted through a Bluetooth interface. Unreported Back Yes (Has a built in one, but it’s not good enough)
A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and an Anti-Interference Post Processing Circuit (Shu, Wang, Mi, Li, and Ren, 2015) http://www.mdpi.com/1424-8220/15/2/3224/htm The device responds linearly to the external pressure with the sensitivity around 13.4 kPa−1. Includes built in processor, built in processor is very big (based on pictures) and we should probably replace it

HeartRateOutput.JPG

15 mm × 30 mm (size of the sensing part) The device responds linearly to the external pressure with the sensitivity around 13.4 kPa−1

HeartRateAccuracy.JPG

Unreported Artery location (arm, neck, leg) Yes (built in processor too big)
OCM1 oximetric sensor http://www.tbpchc.com/eng/medical.php?gid=13 1,8 tot 3,6V,

I2C Compatible

8.0mm x 11.4mm x 2.6mm Heart rate: 3bpm variation for a heartrate between 40 en 240 bp (therefore unsuitable during serious hypothermia)

Oxygen: 3% off for an oxygenpercentage between 70 en 100% (therefore unusable in extreme cases as well)

60 mW Unreported Wrist or finger No
Energy Harvesting Options Research
Energy Harvesting Options Overview
Name Website Size Power Price Notes
ECS 310 Solar Panel https://www.enocean.com/en/enocean_modules/ecs-300/ 35 x 12 x 1 mm 3v, 11 μA - Requires +-200lux (comparable to indoor light, direct sunlight about 32,000 lux
ECT 310 Thermoelectric generator

Barometric Pressure Sensor (Also usable for temperature)

https://www.enocean.com/en/enocean_modules/ect-310-perpetuum/ 14 x 14 x 5 mm Approximately 20mV/K, 40μA/K - Needs to be connected to two areas with significant temperature differences.
LL3-37 Solar panel http://www.flexsolarcells.com/index_files/OEM_Components/Flex_Cells/pages/PowerFilm-Solar-OEM-22-Low-Light-Solar-Cell-Module-LL3-37.php 37 x 100 mm 3V/15μA at 200lux, 460μA at 1,000lux €6.37 (wholesale prices available) Flexible, requires additional UV protection. Expected lifetime: 1 year
PT2.75 Solar Panel http://www.flexsolarcells.com/index_files/OEM_Components/Flex_Cells/specification_sheets/17_FlexSolarCells.com_PowerFilm_Solar_P7.2-75_Specification_Sheet.pdf 90 x 720mm 7v/100mA in direct sunlight €17.71 Flexible, includes UV protection. Very durable. Expected lifetime: 10 years. Bigger sizes available.
TEG2-07025HT-SS Thermoelectric generator https://thermoelectric-generator.com/wp-content/uploads/2014/07/Spec-TEG2-07025HT-SS-rev.pdf 40 x 40 mm 0.6v/ 1.1 (no unit) current at 50K temperature difference €24.63 Undetailed specification

Uer Society and Enterprise aspects

Health Warnings

Hyper- and Hypothermia

Our proof of concept will use a Temperature sensor and a Galvanic skin response sensor. These two sensors can be used to warn people of a potential hypothermia or hyperthermia. When taken separately they can give an approximation of someone’s well being, mostly using averages and estimations. However, as everyone is different, for our application it is important to get a more accurate estimation of someone’s body’s state to base our warnings and actions on.

To get more accurate readings, the sensors will start with baseline measurements of the person in rest. This is to determine their average body temperature and galvanic skin response. For body temperature this is done because the range of possible base temperatures ranges on average from 36.1 to 37.2 degrees centigrade (MedLine Plus team, 2018), and a shift of one degree centigrade in either direction is already enough for a warning; if a person’s core temperature drops by 2 degree centigrade they are already experiencing a mild hypothermia (after a degree drop they experience a severe hypothermia and need medical attention). If a person’s core temperature increases by 1 to 1.5 degrees they either have a fever, or a mild case of hyperthermia. If a person’s body temperature increases by 1.5 to 3 degrees they are experiencing serious hyperthermia, and are in need of medical attention (Calvin, 2018).

Even these measures are estimates based on averages however, and need to be combined with more sensor data for a more accurate warning system. People experiencing dehydration, hypothermia, or hyperthermia have a reduced galvanic skin response, because they stop sweating and their skin dries out. Galvanic skin response tends to rise when sweating as sweat increases conductivity, and tends to drop when the skin dries up. Activities and movements such as sports can also influence galvanic skin response readings, but these can be attributed accordingly when other sensor data is taken into account (Shariff, Hingorani, Albadawi, 2015), such as heart rate data, which during exercise should be between 50 to 85 % of 220-age (Gholipour, 2018) (This heart rate data will also be used to alarm professional help in case of cardiovascular events). Under hypothermia conditions a person’s heart rate will drop, under hyperthermia conditions a person’s heart rate will initially rise, and eventually drop as the person goes into shock. When most or all spikes in galvanic skin response have been attributed to other causes such as physical activity, what is left is the base galvanic skin response. When this is base higher on average than the baseline measurement, this is indicative of a sweaty skin, when this base is lower on average than the baseline measurement, this means the skin is drying out. When people are entering a state of hyper- or hypothermia, their skin eventually dries out as the situation worsens as the body is slowly going into shock.

In the specific conditions our device will be used in hyperthermia seems like a less likely condition, but it can actually still happen through other causes than a high environmental temperature. Another cause for hyperthermia is overexertion. In overexertion the body has produced more heat than it can handle (rather than receiving it from the environment), and will start to sweat until it can no longer do so, making it similar as the other situation yet still relevant to our use case. Another way to therefore detect this situation is to signal a dehydration or hyponatremia in time. A dehydration is a lack of fluids in the body, and hyponatremia is a lack of salts in the body. In the case of hyperthermia the dehydration is caused by excessive sweating, which goes paired with a large loss of salts in the body, meaning in the specific case of hyperthermia, dehydration and hyponatremia go together, and can be predicted by monitoring the amount of salts in a person’s blood. This can be measured using blood sensors mentioned in previous weeks. Blood sodium levels ought to stay between 135 and 145 milliequivalents per liter (Mayo Clinic Staff, 2018); when they fall below this, a person has hyponatremia.

When the suit detects the onset of hypothermia, the drone can be dispatched to send warmer clothes, heat elements, and perhaps a light-weight tent to serve as shelter and protection. When the situation worsens the person will be warned to not actively heat up theri body, and a medical team will be sent to offer professional help. In the case of hyperthermia the drone can be dispatched to send sports drinks to replenish sodium and bring cooling elements. When the situation worsens the person will be warned to no longer ingest any food or drink, and try to cool down actively as much as possible and a team of medical professionnels will be sent. In conclusion, this means there are several options to detect hyperthermia and hypothermia. To detect hypothermia, a galvanic skin response sensor, a heart rate sensor, and a temperature sensor will be utilised. To detect hyperthermia, the galvanic skin response sensor, heart rate sensor, temperature sensor, and sodium level sensor will be utilised.

To combine these sensor readings into a more personal advice, acceptable, risky, and dangerous ranges for each sensor will be compared and combined. When at least two sensors are indicating a risk, a warning will be issued to the wearer, and the wearer will be given the option to decline the dispatch of a drone to send first aid material. When the wearer declines, another warning and drone request will be sent and offered for declination each time another sensor enters the risky range, or a sensor enters the dangerous range. When two or more sensors reach the dangerous range, a request for professional medical attention will be issued and offered for declination.

For the temperature sensor, values in the between baseline - 1 and baseline + 0.5 are ok; values between baseline -1.5 and baseline -1, and baseline +1 and baseline + 1.5 are risky; and values between baseline -2 and baseline -1.5, and baseline +1.5 and +3 are dangerous.

For the sodium level sensor, The ok range is between 140 and 145, the risky range is between 136 and 140, the dangerous range is below 136.

For the galvanic skin response sensor, provided the person is still active which is determined using the heart rate sensor, the ok range is between the midpoint of the baseline measurement and the base of when the person is active and sweating, and the base of when the person is active and sweating. The risky point is between this midpoint and the baseline, and the dangerous range is below the baseline.


Height related issues When people ascend too fast, their blood will expand too fast, sometimes even creating air pockets. This can lead to cerebral and pulmonary oedema, where fluid starts to build up in the brain or lungs. This can be predicted by use of an altimeter to monitor their speed of ascension. This condition is very dangerous, and first aid can’t properly help them. Because of this, when the rate of ascension goes above 305 m a day (Ultimate Kilimanjaro team, 2018), a request for professional help will be offered for declination.

Another problem encounterable at great heights is hypoxia, where the blood oxygen levels are below 60 mm Hg rather than between 75 to 100 mm Hg (Mayo Clinic Staff, 2018). Considering hypoxia can speed up hypothermia, it is important to strictly monitor the blood oxygen levels using the oxygen sensors mentioned in earlier weeks. This too is a condition in which professional help is a necessity.

For the altimeter, the ok range of values is between 0 and 250 m per day. The risky area is between 250 and 285 m per day, the dangerous area is 285 m per day and above, with a warning sent at 250 and 285 m per day. Considering everyone is different, and this indicator uses only one sensor, the user will be able to set the dangerous rate of ascension from the standard 305 m per day to a different level as most people attempting dangerous climbs have practiced and trained often and know their body well.

For the blood oxygen levels, between 80 and 95 mm Hg is the ok range, between 65 and 80 mm Hg is the risky range, and warrants a warning concerning hypoxia and hypothermia. Levels below 65 warrant offering a declination option for professional help.

Drone details

Types of drones

Just as there are surgeons who are specialised in brain, heart, muscle, skin, cancer, etc. surgeries, specialised drones exist. A list can be found at: http://3dinsider.com/types-of-drones/. These different drones should be employed at the right moment, for the right operation. Different situations can occur.


Size

The sizes of drones vary from insect-size to large drones up to the size of a small aircraft. Very small drones (up to 50 cm) (Flynt, 2017) can be used as small surveillance for the hiker, or an emergency device (wearable size) to be employed whenever distress/danger is present. This emergency drone could be used to alarm other people for potential danger, or find the nearest person that can help the hiker in need of help. Small drones (up to 2 m) (Flynt, 2017) can be used to send in medicins/water/first-aid kit, etc. It will be employed from a first-aid post to the corresponding hiker. As the somewhat bigger drones are known to be quite fast, with the current fastest drone to reach up to 314.14 km/h (https://www.youtube.com/watch?v=GlELt3KM_OU), it will be able to be on time and also take the speed of a first responder in the neighbourhood to be a guide. Obviously, this top speed is not needed, which makes it even more plausible to have drones that can guide humans by foot or car. Medium sized drones are usually carried by two people. These drones are not very useful in this project. Large drones go up to the size of a small airplane. A human-carrying drone (Ehang) already exist, but is not able to pick up a person by itself. A person in great danger could be evacuated by this drone, but a person who is heavily injured cannot take the benefit of it. This would be a great follow-up study to do.


Range

The range of a drone is also very important. It can vary from 5 km to 650 km of range (Flynt, 2017). Depending on the use, drones can be specified for its range as well. Typically, bigger drones have a bigger range. However, it is not always useful to employ big drones for a certain task. A trade-off has to be considered. If you want to help someone who only needs some medications but is too far away from a first-aid post for a smaller drone, it would be common sense to send a bigger drone with this larger range span. However, this is not cost-efficient, so a smart implementation would be to, for example send these medications way before (s)he actually needs this. This would have to be sensed in advance with the help of the different sensors on the sensor suit.


Required Materials for Proof of Concept

Shopping List
Object Website Price Estimated Shipping Time
ESP32 MCU https://www.conrad.nl/p/development-printplaat-sbc-nodemcu-esp32-1656367 €10,99 7 days
CHOICE

1). Heartbeat sensor kit (India). Note: don’t know the shipping

2). Kit from China, free shipping but no electrodes

3). (Cheap) finger heartbeat module

1). https://sunor robotics.co.in/sensors/ecg-sensor-module-heart-rate-pulse-with-electrode?zenid=dt4mfi3hoci3st8trm7em3hjp1

2). http://www.volumerate.com/product/3-3v-ecg-monitor-sensor-module-for-arduino-red-works-with-official-arduino-boards-844366286 en https://www.trademed.nl/ecg-electrodes/vivomed-ecg-microtape-elektrode-50-mm-30-st or something similar

3). https://evive.cc/shop/sensor/heartbeat-pulse-sensor/


example: https://www.cnet.com/news/undershirt-monitors-heart-rate-with-wearable-electrodes/

1). €12,60 without shipping

2). €24,07

3). €24,-

1). 7 days

2). 3-4 days

Solar panel (2.5W) https://www.antratek.nl/2-5w-solar-panel €9.95 1 day

Week 6

Deliverables & Milestones

Deliverables

  • Literature Research Sodium Sensor
  • Questionnnaire for users
  • Interview guide for usergroup teachers.
  • Design plan


Milestones

  • Wiki review (contents and final structure brainstorm, for internal use)
  • Ordering electronics parts

Uer Society and Enterprise aspects

Drone Details updated version

Need/Viability

For the suit to be viable, it is essential that actions can be taken once the suit has detected a critical health problem that needs stante pede attention. When such an issue occurs in a city, or even rural area with decent infrastructure, it is fairly easy for emergency medical services to get to the person in question. In fact, when looking at data from 2015 (Mell et al. 2015), gathered from 485 EMS agencies all over the United States, the average time of an EMS unit to arrive at the location where the 911 call was placed was 7 minutes for urban areas. For rural areas, this time was over 14 minutes. The areas were classified using ZIP code information, with rural having a population of less than 2.500, suburban between 2.500 and 50.000 and urban more than 50.000. 625 of the 1.275.529 instances were marked as outliers and were excluded in the study.

One can imagine that in extreme conditions, EMS is not as readily available as on ground level with proper infrastructure. For this reason, companies or non profit organisations arise that provide these services, but not in a traditional manner as you would expect. For instance, the ‘Himalayan Medics’ provide courses and training, besides the regular ‘search & rescue’ services. It is when trained professionals are with you on your journey, that actions can be taken stante pede. If no medical professional is present, someone has to be sent up (or down) the mountain to aid the person that needs help. The time it takes for aid to arrive depends on the location, and can possibly take several hours. Take for instance the mount Everest, the shortest climb from camp to camp -on average- is 3 hours, when the climber is acclimatized to the harsh conditions at such altitudes and crossing sections of mountains like the Khumbu Icefall is definitely not speeding up the process.

To reach a 7 minute response time on average, or let us say 15 minute response time on average, with hand-carried emergency services in such extreme conditions is plain impossible. For this reason, there should be an alternative with decent response times that is triggered when the suit detects an anomaly. Besides an apt response time, adequate care is also very if not more important. It is therefore crucial to not only force a fast response time, but provide the care that is needed on the spot. A study from 2010 (Al-Shaqsi, 2010) shows that response time is too often the performance indicator for EMS even though there is no valid evidence for this to be the case, and present evidence is conflicting this statement. One almost seems to forget that the patient’s health is the goal in this scenario and ought to be used as a performance indicator.

To achieve both a respectable response time combined with adequate medical aid, the suit is linked to a drone station that can dispatch drones when the suit says it is time for medical aid. Drones, as they are airborne, do not care for rugged terrain or icy slopes, and the 600 meters it takes to go from camp A to camp B which takes climbers hours of time, can be overcome by the drone in a matter of seconds. Not unlike an ambulance which has many tools that are specialised for different parts of the body like the brain, heart, muscles, skin, lungs, etc., drones exist in various sizes that can be specialised for various tasks as well. For certain emergencies, it is best to deploy a small drone that provides quick care in the form of a pill or injection. In such an instance, the size of the drone is rather insignificant as long as it can carry said pill or injection, yet speed is essential in this instance. Emergencies that require more equipment can certainly be facilitated with drones of a large size. In this situation, speed is also of importance and certainly realisable.


Size

The sizes of drones vary from insect-size to large drones up to the size of a small aircraft. Very small drones (up to 50 cm) (Flynt, 2017) can be used as small surveillance for the hiker, or an emergency device (wearable size) to be employed whenever distress/danger is present. This emergency drone could be used to alarm other people for potential danger, or find the nearest person that can help the hiker in need of help. Small drones (up to 2 m) (Flynt, 2017) can be used to send in medicins/water/first-aid kit, etc. It will be employed from a first-aid post to the corresponding hiker. As the somewhat bigger drones are known to be quite fast, with the current fastest drone to reach up to 314.14 km/h (https://www.youtube.com/watch?v=GlELt3KM_OU), it will be able to be on time and also take the speed of a first responder in the neighbourhood to be a guide. Obviously, this top speed is not needed, which makes it even more plausible to have drones that can guide humans by foot or car.

Medium sized drones are usually carried by two people. These drones are not very useful in this project. Large drones go up to the size of a small airplane. A human-carrying drone (Ehang) already exist, but is not able to pick up a person by itself. A person in great danger could be evacuated by this drone, but a person who is heavily injured cannot take the benefit of it. This would be a great follow-up study to do.


Range

The range of a drone is also very important. It can vary from 5 km to 650 km of range (Flynt, 2017). Depending on the use, drones can be specified for its range as well. Typically, bigger drones have a bigger range. However, it is not always useful to employ big drones for a certain task. A trade-off has to be considered. If you want to help someone who only needs some medications but is too far away from a first-aid post for a smaller drone, it would be common sense to send a bigger drone with this larger range span. However, this is not cost-efficient, so a smart implementation would be to, for example send these medications way before (s)he actually needs this. This would have to be sensed in advance with the help of the different sensors on the sensor suit.

Literature Research/State of the Art

Sodium sensor

Another important blood parameter to monitor is the patient’s salt level (namely its sodium level). What would be the best fit for such a sensor is the newly developed wearable sweat sensor. This plastic and flexible sensor can be easily worn on the wrist and measures you sweat on a molecular level. This molecular tests are then directly sent to a smartphone, and could in our case be sent to whatever transponder the suit will be equipped with. This sensor has only been developed in 2016 by Ali Javey, of the University of California, and is yet difficult to find on the market (hence no clear price indication).

Unfortunately, after doing some research, this kind of sensor is not useful for this project, since it only measures the sodium level the body expels. No indication is given regarding the level of sodium that resides in the blood. The only other form of sensor capable of doing this is a mouth sensor. However, this would be inconvenient for the user to wear. Keeping this in mind, the salt sensor has not yet been integrated into the smartsuit.


Finger pressure sensor

As some avid climbers may have experienced already, injuries to the hand and fingers are common. This probably sounds logical as climbers put increased amounts of weight on just their hands and fingers for which they are not suited by nature, except experiencing an injury to the hand or fingers is definitely not pleasant, as they are used every day, almost continuously. For extreme climbers, taking good care of hands and fingers is especially important. They might just find themselves in extreme conditions, where once the injury has manifested(?) itself, proper actions can not be taken to prevent the injury from worsening and the mission might even have to be aborted. One of the most common injuries is a tendon pulley injury. To understand this injury, one must be at least acquainted with how the fingers work mechanically.

Inside Finger.JPG

Figure 1. Finger pulley anatomy

To start off, fingers have no muscles. The mechanic functioning of the fingers is controlled by muscles in the inside of the forearm, that have tendons attached to the middle and end of the finger bone. You can imagine the finger as a brake cable on a bike. In the image above you can roughly see how this looks anatomically. As discussed in a BMC climbing injury sypmosium in 2016 with presenters. Dr. Volker Schoffl (surgeon, climber 8a) and Dr. Isa Schoffl (Paediatrician, climber 7a+), fingers comprise of 52% of all climber injuries, with pulley injuries being 60% of all finger injuries (31,2% of total injuries). This injury is mainly caused by what is known as the “Crimp grip”.

Crimp Grip.JPG

Figure 2. Crimp Grip

The “Crimp grip”, as shown above, is not a natural position for the hand, and places tremendous amounts of force on the pulleys in the fingers, especially on annular pulleys A2 (Jebson & Steyers, 1997) and A4 (Schöffl et al., 2009). This specific grip combined with sudden slipping of the feet causes many injuries. It is therefore that experienced climbers often prefer other grips, due to either a prior injury or just experience.

Treatment of such an injury is important, as is explained above. However, in order to treat this injury, the climber must be aware that this is happening in their fingers. The sooner this injury is treated properly, the sooner it is alleviated. Inexperienced climbers tend to “climb through the pain”, which results in longer recovery time than is necessary had they properly taken care of it when it first appeared.

One of the signs of a ruptured pulley besides pain is pressure inside the finger, resulting in swelling of the fingers (Crowley, 2016). Gloves that warn you when you strain your fingers too much or that pressure is building inside your finger could significantly reduce the time it takes for extreme climbers to notice that they are putting too much stress on their fingers, or that their grip is wrong. Someya Group has researched and built fabric using carbon nanotubes, graphene and an elastic polymer that could act as a pressure sensitive glove. They have tested it on an artificial blood vessel, and were able to detect pressure changes and the speed of pressure propagation (Lee et al., 2016). The sensing range and sensitivity can be adjusted by changing the thickness of the fibre layer, concentration of the conductive filler in the fibre, pad size and width/length ratio of the transistor.

For the suit, this material would be ideal in detecting if fingers have swollen abnormally, and while it is there anyways, detect when climbers are using the wrong grip, or a grip wrong, resulting in too much pressure on one of the pulleys of the fingers. This can not only improve recovering times, as early indication significantly reduces recovery time (such is the case for basically every injury), but also help prevent the injury in the first place by detecting too much pressure on certain parts of the finger.

Design Plan

Design Plan.jpg

Questionnaire & Interview Guide

Questionnaire

User Questionnaire


Interview Guide Rockclimbing/Mountaineering teacher

  • Short summary of the suit:

This project is an integration of a Smartwear suit and a drone, mountaineers/rock climbers are the target audience. The suit will be capable of measuring temperature, heart rate, galvanic skin response (dehydration), blood oxygen levels, height, GPS location, and pressure in the finger (overexertion/inflammation). This information will be utilised to determine (possible) health related issues.

When the problem hasn’t developed too far, the suit will issue a warning. In case of deterioration the suit will ask if the wearer would like for a drone to leave basecamp and bring first aid materials the wearer can use on themselves. In the event the problem has progressed too far the suit will offer to send medical personnel, and will give the user the option to decline. If the user agrees or has not declined within a certain time frame, the suit will send the GPS location and sensor readings to medical personnel. It was decided to implement it in this fashion so that a user that has become incapable of accepting can still receive the necessary help.

  • Do you consider your sport an “Extreme sport”, and why?
  • What kind of health related problems do you encounter, and which problems do your students often encounter?
  • Has either you or one of your students ever suffered an accident when performing this sport, and if so could you describe it?
  • Does first aid generally arrive fast enough, and how difficult is it to be reached by medical personnel?
  • How do you prepare your students for practicing this sport?
  • How high can a person climb per day without exposing themselves to risks?
  • What kind of clothing article should the sensors be integrated in to make it as easy as possible to use for you and your students without influencing sensor accuracy?
  • How long should the suit last between charging moments?
  • For how long do you climb in general before finding a place to charge devices, and for how long do you climb with students?
  • Is it more important for the suit to be more durable by using wireless communication between parts, impacting battery life strongly, or should the suit use wired connections saving battery life but being less durable?
  • Are there certain features the suit is still lacking to make it more usable to you or your students?

Week 7

Health Warnings (updated)

Hyper- and Hypothermia Our proof of concept will use a Temperature sensor and a Galvanic skin response sensor. These two sensors can be used to warn people of a potential hypothermia or hyperthermia. When taken separately they can give an approximation of someone’s well being, mostly using averages and estimations. However, as everyone is different, for our application it is important to get a more accurate estimation of someone’s body’s state to base our warnings and actions on.

To get more accurate readings, the sensors will start with baseline measurements of the person in rest. This is to determine their average body temperature and galvanic skin response. For body temperature this is done because the range of possible base temperatures ranges on average from 36.1 to 37.2 degrees centigrade (MedLine Plus team, 2018), and a shift of one degree centigrade in either direction is already enough for a warning; if a person’s core temperature drops by 2 degree centigrade they are already experiencing a mild hypothermia (after a degree drop they experience a severe hypothermia and need medical attention). If a person’s core temperature increases by 1 to 1.5 degrees they either have a fever, or a mild case of hyperthermia. If a person’s body temperature increases by 1.5 to 3 degrees they are experiencing serious hyperthermia, and are in need of medical attention (Calvin, 2018).

Hypothermia.PNG

Figure 1: Accidental hypothermia in severe sepsis. The graph suggests the relationship between inflammation and temperature in severe sepsis. As inflammation increases, temperature accordingly increases. After the point of ‘critical inflammation’ core body temperature drops, this may be an adaptive response to prevent further damage mediated through inflammation.

“Accidental hypothermia” is described as the sudden drop of temperature due to environmental causes. In this figure, one can see that there is a relationship between inflammation and temperature in severe sepsis. At the intersection of the two graphs, “critical inflammation” has been reached, causing hyperthermia to turn into hypothermia. This point can be seen as the point at which the sporter is in great danger and needs medical assistance.

This would mean that a person is “safe” regarding sepsis when (s)he is between 36.1 to 40 degrees Celsius (hyperthermia). When a person hits the 40 degrees and drops down to 32 (hypothermia), one can conclude that the person is under severe sepsis. https://ugpathsoc.wordpress.com/2014/01/15/pyrogens-cryogens-and-bears-oh-my/

Even these measures are estimates based on averages however, and need to be combined with more sensor data for a more accurate warning system. People experiencing dehydration, hypothermia, or hyperthermia have a reduced galvanic skin response, because they stop sweating and their skin dries out. Galvanic skin response tends to rise when sweating, as sweat increases conductivity, and tends to drop when the skin dries up. Activities and movements such as sports can also influence galvanic skin response readings, but these can be attributed accordingly when other sensor data is taken into account (Shariff, Hingorani, Albadawi, 2015), such as heart rate data, which during exercise should be between 50 to 85 % of 220-age (Gholipour, 2018) (This heart rate data will also be used to alarm professional help in case of cardiovascular events). Under hypothermia conditions a person’s heart rate will drop, under hyperthermia conditions a person’s heart rate will initially rise, and eventually drop as the person goes into shock.When most or all spikes in galvanic skin response have been attributed to other causes such as physical activity, what is left is the base galvanic skin response. When this is base higher on average than the baseline measurement, this is indicative of a sweaty skin, when this base is lower on average than the baseline measurement, this means the skin is drying out. There is no such data found on the exact values of when things get dangerous, but what could be done is looking at the derivatives of the increase/decrease of the heart hate associated with hyper/hypothermia.

In the specific conditions our device will be used in hyperthermia seems like a less likely condition, but it can actually still happen through other causes than a high environmental temperature. Another cause for hyperthermia is overexertion. In overexertion the body has produced more heat than it can handle (rather than receiving it from the environment), and will start to sweat until it can no longer do so, making it similar as the other situation yet still relevant to our use case. Another way to therefore detect this situation is to signal a dehydration or hyponatremia in time. A dehydration is a lack of fluids in the body, and hyponatremia is a lack of salts in the body. In the case of hyperthermia the dehydration is caused by excessive sweating, which goes paired with a large loss of salts in the body, meaning in the specific case of hyperthermia, dehydration and hyponatremia go together, and can be predicted by monitoring the amount of salts in a person’s blood. This can be measured using blood sensors mentioned in previous weeks. Blood sodium levels ought to stay between 135 and 145 milliequivalents per liter (Mayo Clinic Staff, 2018); when they fall below this, a person has hyponatremia.

Dehydration.PNG

Figure 2: Effects of dehydration (Bean 2004:84) http://kilcooleac.com/dehydration-and-fluids-in-running/

As can be seen from the figure 2, it is getting dangerous when someone loses more than 2 kg of fluid. This will result in impairing. Code orange: 2 kg to 4 kg, code red: >4kg. However, these are all absolute losses, which can actually differ from person to person. Figure 2 and 3 (also) show relative weight losses. Now: code green: 0 to 2%, code orange: 2% to 6%, code red: >6%

Physical Performance.PNG

'Figure 3: Relative dehydration risks https://tunedintocycling.com/2012/07/

A galvanic skin response detector is able to measure a person’s hydration level. It is expressed in gain (dB). Figure 9 shows simulated sensitivity. One can see that after drinking, the gain will increase accordingly. This is just a proof that galvanic skin responses work. No further useful conclusions with respect to this project can be made with this information. Asogwa, C., Collins, S., Mclaughlin, P., & Lai, D. (2016). A Galvanic Coupling Method for Assessing Hydration Rates. Electronics, 5(4), 39. https://doi.org/10.3390/electronics5030039

Galvanic.PNG

http://www.ilocis.org/documents/chpt42e.htm

In the link above, there is a section under “Rational indices”, which formulates the equations and how to interpret the results of calculating the HSI (heat stress index) and ITS (index of thermal stress).

Physiological.PNG

Figure 3: Consequences of dehydration (Montain, 1992).

“Although the symptoms of heat illness can vary widely among individuals, heat exhaustion due to dehydration is often evidenced by irritability, sudden fatigue, and lightheadedness, with nausea and headache also possible. Skin color is often pale with normal-to-profuse sweating. Heat stroke is characterized by high core temperature, reddened skin, and normal-to-profuse sweating. Severe heat stroke is characterized by central nervous system dysfunction (eg, loss of motor coordination, delirium), and, in the most serious cases, loss of consciousness leading to coma.“ (Murray, 1996) Murray, R. (1996). Dehydration, Hyperthermia, and Athletes: Science and Practice. Retrieved from https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1318513/pdf/jathtrain00019-0058.pdf

"We found that the magnitude of increase in core temperature and heart rate and the decline in stroke volume were directly related to the body weight loss (and thus dehydration accrued) during exercise. Thus, when subjects exercise at 62% to 67% Vo2max under the present environmental conditions (33°C dry bulb, 50% relative humidity, wind speed 2.5 m/sec), the optimal rate of fluid ingestion to attenuate hyperthermia and cardiovascular drift is the rate that most closely matches fluid loss through sweating, at least until the rate of fluid ingestion replaces 81% of sweat loss."' (Montain, 1992). Montain SJ, Coyle EF. The influence of graded dehydration on hyperthermia and cardiovascular drift during exercise. J Appl Physiol. 1992;73: 1340-1350.

When the suit detects the onset of hypothermia, the drone can be dispatched to send warmer clothes, heat elements, and perhaps a light-weight tent to serve as shelter and protection. When the situation worsens the person will be warned to not actively heat up theri body, and a medical team will be sent to offer professional help. In the case of hyperthermia the drone can be dispatched to send sports drinks to replenish sodium and bring cooling elements. When the situation worsens the person will be warned to no longer ingest any food or drink, and try to cool down actively as much as possible and a team of medical professionnels will be sent. In conclusion, this means there are several options to detect hyperthermia and hypothermia. To detect hypothermia, a galvanic skin response sensor, a heart rate sensor, and a temperature sensor will be utilised. To detect hyperthermia, the galvanic skin response sensor, heart rate sensor, temperature sensor, and sodium level sensor will be utilised.

To combine these sensor readings into a more personal advice, acceptable, risky, and dangerous ranges for each sensor will be compared and combined. When at least two sensors are indicating a risk, a warning will be issued to the wearer, and the wearer will be given the option to decline the dispatch of a drone to send first aid material. When the wearer declines, another warning and drone request will be sent and offered for declination each time another sensor enters the risky range, or a sensor enters the dangerous range. When two or more sensors reach the dangerous range, a request for professional medical attention will be issued and offered for declination.

For the temperature sensor, values in the between baseline - 1 and baseline + 0.5 are ok; values between baseline -1.5 and baseline -1, and baseline +1 and baseline + 1.5 are risky; and values between baseline -2 and baseline -1.5, and baseline +1.5 and +3 are dangerous.

For the sodium level sensor, The ok range is between 140 and 145, the risky range is between 136 and 140, the dangerous range is below 136.

For the galvanic skin response sensor, provided the person is still active which is determined using the heart rate sensor, the ok range is between the midpoint of the baseline measurement and the base of when the person is active and sweating, and the base of when the person is active and sweating. The risky point is between this midpoint and the baseline, and the dangerous range is below the baseline.

Height related issues

When people ascend too fast, their blood will expand too fast, sometimes even creating air pockets. This can lead to cerebral and pulmonary oedema, where fluid starts to build up in the brain or lungs. This can be predicted by use of an altimeter to monitor their speed of ascension. This condition is very dangerous, and first aid can’t properly help them. Because of this, when the rate of ascension goes above 305 m a day (Ultimate Kilimanjaro team, 2018), a request for professional help will be offered for declination.

Another problem encounterable at great heights is hypoxia, where the blood oxygen levels are below 60 mm Hg rather than between 75 to 100 mm Hg (Mayo Clinic Staff, 2018). Considering hypoxia can speed up hypothermia, it is important to strictly monitor the blood oxygen levels using the oxygen sensors mentioned in earlier weeks. This too is a condition in which professional help is a necessity. For the altimeter, the ok range of values is between 0 and 250 m per day. The risky area is between 250 and 285 m per day, the dangerous area is 285 m per day and above, with a warning sent at 250 and 285 m per day. Considering everyone is different, and this indicator uses only one sensor, the user will be able to set the dangerous rate of ascension from the standard 305 m per day to a different level as most people attempting dangerous climbs have practiced and trained often and know their body well. For the blood oxygen levels, between 80 and 95 mm Hg is the ok range, between 65 and 80 mm Hg is the risky range, and warrants a warning concerning hypoxia and hypothermia. Levels below 65 warrant offering a declination option for professional help. Not all data is known, so sometimes, only an educated guess is available. However, other tricks can be implemented, like taking the derivative can help “guessing” the problem. For example, heart rates keep changing, this does not mean that when the heart rate increased with 30 beats per minute is necessarily dangerous. There is a factor that is being forgotten which is time. If your heartbeat increases with 30 beats per minute in 10 minutes, this is not a coincidence. However, when this changes within a 10 seconds, one should ring a bell. Therefore, the slope of the increase is a very important characteristic.

Design Plan (updated)

HikeTech (wireless).jpg

HikeTech (wired).jpg

Shirt: Röjk (2017). Röjk SuperBase Midlayer. Retrieved from https://www.campz.nl/outdoor-uitrusting/klimmen/klimkleding/roejk.html

CR2032, wired: batteryBob (n.d.). CR2032 WITH CONNECTOR COMP-32CAN. Retrieved from https://www.batterybob.com/products/4034-cr2032-with-connector-comp-32can/

ZOE-M8B: Alpha Micro Components Ltd (n.d.). ZOE-M8B - Ultra-compact, super low power u-blox M8 GNSS SiP with Super-E mode. Retrieved from http://www.alphamicro.net/franchises/u-blox/zoe-m8b.aspx

LM35A: Probots (n.d.). LM35 TEMPERATURE SENSOR WITH ANALOG OUTPUT. Retrieved from https://probots.co.in/index.php?main_page=product_info&products_id=115

Li-Po battery: Adventure Electronics BD (n.d.). LI-PO BATTERY 3.7V. Retrieved from https://adventureelectronicsbd.com/product/li-po-battery-3-7v/

ESP32: Factory Forward (n.d.). ESP WROOM 32 ESP32 WiFi and Bluetooth Module. Retrieved from https://www.factoryforward.com/product/esp-wroom-32-esp32-wifi-bluetooth-module/

AD8233: Mouser (n.d.). Analog Devices AD8232 & AD8233 Heart Rate Monitor Front End. Retrieved from https://www.mouser.in/new/Analog-Devices/adi-ad8232-amplifier/

ECG electrodes: Goodsomnia (n.d.). Electrodes for Pocket ECG. Retrieved from https://goodsomnia.com/featured-products/electrodes-pocket/

Galvanic skin response sensor: Alibaba (n.d.). Sichiray Galvanic Skin Response Sensor (GSR - Sweating) of current sensor suite measurable skin resistance conductivity sensor ACC0003. Retrieved from https://guide.alibaba.com/shop/sichiray-galvanic-skin-response-sensor-gsr-sweating-of-current-sensor-suite-measurable-skin-resistance-conductivity-sensor-acc0003_1008474209.html

BMP280: SOS Electronics (n.d.). BMP280. Retrieved from https://www.soselectronic.com/products/bosch/bmp280-186790

Week 8

Deliverables & Milestones

Deliverables

  • Research Notification Systems
  • Survey Results Summary

Milestones

  • Working algorithm with odds calculation
  • Presentation

Design Plan (updated)

Hiketech wired2.0.jpg

Hiketech2.0.jpg

Health Warnings (addition)

Biketemp.jpg

Figure 1: The body temperature change IN VEINS: oesophageal, tympanic, arterial and jugular venous blood temperature. As can be seen, a linear increase/decrease to cool down/heat up the body, trying to keep the body temperature constant. (Nybo, 2012). f(t) = 0.9e-3*t+T_base

This figure is a comparison of how quickly the body temperature can change in veins. One can calculate that for this particular case, the temperature increase is approximately 0.9e-3 degrees Celsius per second. Recovery has a faster decrease: 0.08 degrees Celsius per second (Nybo, 2012).

BodyTempMin.jpg

In this figure, the heart rate and body temperature have been measured for a person who went from walking (at time 0), to running (at time 5 min), to sitting (at time 35). The different curves show different speeds. The blue curve corresponds to running at 6km/h, red to 8km/h and green to 10km/h. Error bars have been included in this figure meaning that several people participated in this research. So note: Two of the seven subjects gave up 15 and 20 min after running started at 10 km/h because of difficulty maintaining the pace. Therefore, seven datasets collected at each time point, except for 20 min at 10 km/h (n= 6) and from 25 min to 34 min at 10 km/h (n=5) (Iwasaki, 2015). For the algorithm, hiking is more of a “walking-pace” intensity level with an increasing intensity when going on slopes or when actually climbing. Therefore, we will compare this intensity with the red curve (also because the green curve is incomplete). For the heart rate, the increase coincides most with a logarithmic function. Thus, when starting to increase the intensity at time = 5 min: HR = HR_base + 25 + log_1.05425(t+1) per minute. As one can see, the body temperature increases exponentially with 1.00054586 per minute or T = T_base*1.000272893^t, where t is in 30 seconds. As not a lot of data points have been taken, the temperature decrease while resting seems to linearly decrease with T = T_base-0.00333t per 30 sec (Iwasaki et al., 2015).

Heartrate resp.jpg

This figure shows the relation between heart rate and intensity for normal and abnormal heart rate responses. This curve has to be taken into account when also considering people with a cardiac dysfunction. For this project, when the heart rate increases with time, one can conclude that the intensity of the sport is increasing as well (Chaudhry et al., 2017).

Nes et al. (2013) have developed an equation to calculate the maximum heart rate of a person. This is: HRmax = 211 − (0.64 × age). This is not the only way to calculate this. There are a lot of other equations which have almost similar results as Nes et al. For this project, we have used this one as it is the most general one. If time would have permitted, more accurate equations would have been used which are, e.g, dependent on the gender and age as well.

Literature Research/State of the Art

Notification System

Visual and auditory user notification methods for smart-home hazard detector

This device detects developing hazardous levels of smoke or carbon monoxide and gives warning signals using lights (three options), sounds/speech (using a speaker), and alarm horns. The hazard level is accessed and compared to preset threshold levels, based upon which alarms can be activated. The device is designed to tie in with smart-home solutions (Fadell et al., 2014).


Notification system

An application was designed that gathers information from other apps on one’s phone, and places the user on a waiting list. It shares personal information the user allows the app to share, and receives notifications with information or waiting list data (West, 2016).

Survey Results Summary

A survey was conducted with mountaineers/rock climbers as the target audience. Only three participants responded, one of which a mountaineering teacher. The most often occuring issues/conditions reported were falling, long term muscle injuries, and exhaustion, the latter also being identified as a cause of other injuries. The main symptoms of these issues being chafing wounds, muscle injuries and low blood sugar levels. Clothing hardly gets damaged, though they do prefer to cover up as much as possible to protect against the sun. The daily height to climb was reported as being dependant on fitness according to the teacher. 7 single pitches and 2000m were mentioned as well. The participants would be ok with a suit that monitors their bodily functions, as long as it’s not available to just anyone and they have a say in it. One of the participants liked they idea of the feedback it could provide. The respondents would like the garment to be a t-shirt, as well as light and comfortable and not too noticeable, long sleeve merino shirts were mentioned as a good option. Average climbing times were reported to be 3, 7, and 8 hours. The participants would prefer the suit to measure heart rate, blood pressure, breaths per minute, body temperature, blood sugar levels, stress hormones, oxygen, and pressure. They prefer notifications to be received through sounds or vibrations, with more exact information being available on their phone. One participant would only like to see the odds that the warning was accurate when they ask for it. One participant would like the suit to last for 10 hours on a charge, two for 72 hours (three days). The permissible charging times for the suit were reported to be two hours, six hours and eight hours. All participants would prefer a wired connection between suit components over a bluetooth connection even though this is more fragile, to conserve power. The participants would agree to the suit sending their data to nearby rescue posts, but only if used for alarms, and only if the cancel period times out or if they chose to share. All participants have a SIM card. The teacher likes the suit for “guided trips to high altitude mountains with clients who are not self-sufficient”, and another participant mentioned the suit should add to the currently available gear like a phone or gps watch. They also mention they would like it for solitary extreme sporting, but no as much for when in groups as they would rely on others for monitoring.

Statistics

Injuries and causes

It is very difficult to provide actual statistics and data regarding the number of accidents in general. No actual worldwide database with such data can be found. However, we did find statistics regarding injuries in the US. These data are fairly outdated (up till 2006). However, they can be used as a guideline, especially since the trend throughout the years is more relevant than the actual year itself. By this we mean that if the number of accidents stays approximately stationary between 2000 and 2006, then some conclusions can be drawn regarding the accidents in 2017.

The statistics show that every year, approximately 100 to 150 injuries related to mountaineering occur in the United States alone.

US Mountaineering.jpg

From these accidents, fractures, lacerations and bruises are the most common type of accident. However, these can hardly be prevented. Our SmartSuit can be an asset here, in such way that the user can directly communicate with the drone/ rescue post. However, preventive warnings are of little use here.

If you look one step further, you notice that the most common accident caused by external factors are Hypothermia, Frostbite and mountain sickness. By monitoring vital functions, our SmartSuit could provide preventive warnings and reduce the risk of accidents.

In short, the SmartSuit can reduce the number of accidents by providing warnings for all externally-induced causes (such as Hypothermia). For the other causes, such as fractures, the suit can be used to monitor the bodily functions while help is on the way (e.g. oxygen level) while also provide communication between the user, rescue post and drone. Lastly, using the GPS tracker in the suit, the rescue post can locate the person in question and reduce time needed to provide help.

Pie chart.jpg

(S.n., 2006)

Week 9

References

123Accu.nl. (2018). Apple iPhone 5s accu (1500 mAh, 123accu huismerk). Retrieved from https://www.123accu.nl/Mobiele-telefoon-accu/Apple/616-0652-p275360.html

Abegg, S. (2006). A Mostly-Graphical Presentation of Mountaineering Accident Statistics. Stephabegg.com. Retrieved on June 17th 2018, from http://www.stephabegg.com/home/projects/accidentstats

Abreu, M. M., (2017). U.S. Patent No. 15/602523. Tortola: Geelux Holdings Ltd.

Acciaroli, G., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2018). Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives. Biosensors, 8(1), 24.

Al-Shaqsi, S. Z. K. (2010). Response time as a sole performance indicator in EMS: Pitfalls and solutions. Open Access Emergency Medicine : OAEM, 2, 1–6.

Backe, S., Ericson, L., Janson, S., & Timpka, T. (2009). Rock climbing injury rates and associated risk factors in a general climbing population. Scandinavian journal of medicine & science in sports, 19(6), 850-856.

Ball, JR & Evans, CH (2001) Safe Passage: Astronaut Care for Exploration Missions. Washington DC, NATIONAL ACADEMY PRESS

Bandodkar, A. J., & Wang, J. (2014). Non-invasive wearable electrochemical sensors: a review. Trends in biotechnology, 32(7), 363-371.

Bartholmai, M., & Neumann, P. (2010). Micro-drone for gas measurement in hazardous scenarios via remote sensing. In Proceedings of.

Bergmann, J. H., Chandaria, V., & McGregor, A. (2012). Wearable and implantable sensors: the patient’s perspective. Sensors, 12(12), 16695-16709.

Benaron, D. A., (2015). U.S. Patent No. 14/864,860. San Francisco: AliphCom

BMC Climbing Injury Symposium 2016 (Facebook Event). (n.d.). Retrieved from https://www.facebook.com/events/1729266083994236/

Bonato, P., (2010). Wearable Sensors and systems. 25-36

Bosch SensorTech. (2018). BMP280 Digital Pressure Sensor. Retrieved on 20 May 2018, from https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-19.pdf.

Brand, van den, J., de Kok, M., Sridhar, A., Cauwe, M., Verplancke, R., Bossuyt, F., ... & Vanfleteren, J. (2014, September). Flexible and stretchable electronics for wearable healthcare. In Solid State Device Research Conference (ESSDERC), 2014 44th European (pp. 206-209). IEEE.

Brocherie, F., Girard, O., & Millet, G. P. (2015). Emerging environmental and weather challenges in outdoor sports. Climate, 3(3), 492-521.

Brymer, E. (2009). The extreme sports experience: a research report. IFPRA world, 6-7.

Brymer, E., Downey, G., & Gray, T. (2009). Extreme sports as a precursor to environmental sustainability. Journal of Sport & Tourism, 14(2-3), 193-204.

Calvin, K. (2018). Hyperthermia: too hot for your health. National Institutes of Health (NIH). Retrieved May 25, 2018, from https://www.nih.gov/news-events/news-releases/hyperthermia-too-hot-your-health-1

Carlsen, K. H. (2012). Sports in extreme conditions: the impact of exercise in cold temperatures on asthma and bronchial hyper-responsiveness in athletes. Br J Sports Med, 46(11), 796-799.

Chaudhry, S., Kumar, N., Behbahani, H., Bagai, A., Singh, B. K., Menasco, N., … Myers, J. (2017). Abnormal heart-rate response during cardiopulmonary exercise testing identifies cardiac dysfunction in symptomatic patients with non-obstructive coronary artery disease. International Journal of Cardiology, 228, 114–121. https://doi.org/10.1016/J.IJCARD.2016.11.235

Climbing finger pulley injury....to crimp or not to crimp? (2017, December 22). Retrieved from https://www.mapleclinic.ie/bloghome/fingerpulleyinjury/

Crowley, T. (2016). The Flexor Tendon Pulley System and Rock Climbing. Journal of Hand and Microsurgery, 04(01), 25-29. doi:10.1007/s12593-012-0061-3

Costa, G., Keulen, V., van Rijsbergen, R. (2016), “ePatch, The Electronic Band-Aid”, research by Fontys Hogeschool Techniek & Logistiek, commissioning company: Yellow Factory

EC (2007) 12th Implementation Report. COM(2007) 155. Brussels: European Commission http://www.splitboardmag.com/article/communication-devices-mountains/

EE Herald, “SPI Bus interface”, http://www.eeherald.com/section/design-guide/esmod12.html

Eliasson, Jens, Per Lindgren, and Jerker Delsing, “A Bluetooth-based Sensor Node for Low-Power Ad Hoc Networks,” Journal of Computers, vol. 3 (5), pp. 1–10, 2008.

Fadell, A. M., Rogers, M. L., Sloo, D., Veron, M., Guen, S., Le, & Webb, N. (2014). U.S. Patent No. US20180137745A1. Washington, DC: U.S. Patent and Trademark Office.

Figure 1, Finger pulley anatomy retrieved from http://www.turntillburn.ch/research/BIOMECHPAP.htm

Figure 2, Crimp Grip retrieved from https://web.archive.org/web/20110930151110/http://www.nicros.com/training/articles/finger-tendon-pulley-injury/

Finger Tendon Pulley Injury. (n.d.). Retrieved from https://web.archive.org/web/20110930151110/http://www.nicros.com/training/articles/finger-tendon-pulley-injury/

Gardner, T., (2015), “Popularity and economic benefit of mountaineering: instant expert”, retrieved from https://www.thebmc.co.uk/participation-in-climbing-mountaineering

Geddes, L. (2016). Wearable sweat sensor paves way for real-time analysis of body chemistry. Nature. Retrieved on 29 May 2018 from https://www.nature.com/news/wearable-sweat-sensor-paves-way-for-real-time-analysis-of-body-chemistry-1.19254

Gholipour, B. (2018). What Is a Normal Heart Rate?. Live Science. Retrieved May 25, 2018, from https://www.livescience.com/42081-normal-heart-rate.html

GMB. (2015). Low temperature LiPo. Retrieved from http://www.gmbattery.com/product/showproduct.php?lang=en&id=33

Gorgutsa, S., Bélanger-Garnier, V., Ung, B., Viens, J., Gosselin, B., LaRochelle, S., & Messaddeq, Y. (2014). Novel wireless-communicating textiles made from multi-material and minimally-invasive fibers. Sensors, 14(10), 19260-19274.

Gibbs, Y. (2017, May 11). Prandtl-D Aircraft. Retrieved from https://www.nasa.gov/centers/armstrong/news/FactSheets/FS-106-AFRC.html

Greene, J., Louis, J., Korostynska, O., & Mason, A. (2017). State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes—The Need for Novel Non-Invasive Techniques. Biosensors, 7(1), 11.

Griffith, J., Cluff, K., Eckerman, B., Aldrich, J., Becker, R., Moore-Jansen, P., & Patterson, J. (2018). Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts. Sensors, 18(4), 1022.

Himalayan Medics. (n.d.). Retrieved June 2, 2018, from http://www.himalayanmedics.com/services.php#services

Huey, R. B., & Eguskitza, X. (2001). Limits to human performance: elevated risks on high mountains. Journal of Experimental Biology, 204(18), 3115-3119.

Ichikari, R., Ruiz, L.C.M., Kourogi, M. (2015). Indoor floor-level detection by collectively decomposing factors of atmospheric pressure. IEEE Xplore. https://ieeexplore.ieee.org/abstract/document/7346776/

International Federation of Sport Climbing, “Key Figures”, retrieved from https://www.ifsc-climbing.org/index.php/media-centre/key-figures-2

Iwasaki, Wataru & Nogami, Hirofumi & Takeuchi, Satoshi & Furue, Masutaka & Higurashi, Eiji & Sawada, Renshi. (2015). Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter. Sensors. 15. 25507-25519. 10.3390/s151025507.

Jebson, P. J., & Steyers, C. M. (1997). Hand Injuries in Rock Climbing. The Physician and Sportsmedicine, 25(5), 54-63. doi:10.3810/psm.1997.05.1341

Jones, L., (2008), “Extreme sport growing in popularity”, retrieved from http://xtremesport4u.com/extreme-land-sports/extreme-sport-growing-in-popularity/

JST ERATO Someya Bio-harmonized Electronics Project. (n.d.). Retrieved from http://www.ntech.t.u-tokyo.ac.jp/en/project/goal_index.html

Kanas, N, & Manzey, D (2008). Space Psychology and Psychiatry. Springer Dordrecht.

Kim, J., Kwon, S., Seo, S., & Park, K. (2014, August). Highly wearable galvanic skin response sensor using flexible and conductive polymer foam. In Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE (pp. 6631-6634). IEEE.

Koch, E., & Dietzel, A. (2016). Skin attachable flexible sensor array for respiratory monitoring. Sensors and Actuators A: Physical, 250, 138-144. doi:10.1016/j.sna.2016.09.020

L, R. (2018). World's fastest drone: 200MPH 6s XLR. Youtube. Retrieved on June 5th 2018, from https://www.youtube.com/watch?v=GlELt3KM_OU.

Landau, E. (2015, January 22). Helicopter Could Be 'Scout' for Mars Rovers. Retrieved from https://www.jpl.nasa.gov/news/news.php?feature=4457

Lee, Kang, “A Smart Transducer Interface Standard for Sensors and Actuators,” in The Industrial Information Technology Handbook, Zurawski, R., Ed., Boca Raton, FL, CRC Press, 2005, pp. 1–16.

Lee, J., Kim, D., Ryoo, H. Y., & Shin, B. S. (2016). Sustainable wearables: wearable technology for enhancing the quality of human life. Sustainability, 8(5), 466.

Lee, Jin-Shyan, Yu-Wei Su, and Chung-Chou Shen, “A Comparative Study of Wireless Protocols: Bluetooth, UWB, ZigBee, and Wi-Fi,” presented at the 33rd Annual Conference of the IEEE Industrial Electronics Society (IECON), Taipei, Taiwan, 2007.

Lee, S., Reuveny, A., Reeder, J., Lee, S., Jin, H., Liu, Q., . . . Someya, T. (2016). A transparent bending-insensitive pressure sensor. Nature Nanotechnology, 11(5), 472-478. doi:10.1038/nnano.2015.324

Levine, J, & Conner, M. (2017, June 29). Could This Become The First Mars Airplane? Retrieved from https://www.nasa.gov/centers/armstrong/features/mars_airplane.html

Linke, B. (2008). Overview of 1-Wire Technology and Its Use. Retrieved from https://pdfserv.maximintegrated.com/en/an/AN1796.pdf

Ma, J. L. G., & Dutch, M. J. (2013). Extreme sports: Extreme physiology. Exercise‐induced pulmonary oedema. Emergency Medicine Australasia, 25(4), 368-371.

Magno, M., Salvatore, G. A., Mutter, S., Farrukh, W., Troester, G., & Benini, L. (2016, May). Autonomous smartwatch with flexible sensors for accurate and continuous mapping of skin temperature. In Circuits and Systems (ISCAS), 2016 IEEE International Symposium on (pp. 337-340). IEEE.

Majumder, S., Mondal, T., & Deen, M. J. (2017). Wearable sensors for remote health monitoring. Sensors, 17(1), 130.

Malashenkova, M. (2016, October). Extreme sports in Extreme conditions. Paper presented at ITP Sport, Exercise & Health Research Symposium, Institute of Sport & Adventure (ISA), Otago Polytechnic (OP).

Mansor H., Shukor M.H.A., Meskam S.S., Rusli N.Q.A.M., Zamery N.S. Body temperature measurement for remote health monitoring system; Proceedings of the 2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA); Kual

Mayo Clinic Staff. (2018, May 08). Hyponatremia. Retrieved May 25, 2018, from https://www.mayoclinic.org/diseases-conditions/hyponatremia/symptoms-causes/syc-20373711

Mayo Clinic Staff (2018, Januari 11). Hypoxemia (low blood oxygen). Retrieved May 25, 2018, from https://www.mayoclinic.org/symptoms/hypoxemia/basics/definition/sym-20050930

McGrath, M. J., & Scanaill, C. N. (2013). Key Sensor Technology Components: Hardware and Software Overview. In Sensor Technologies (pp. 51–77). Berkeley, CA: Apress. https://doi.org/10.1007/978-1-4302-6014-1_3

MedLine Plus team (2018). Body temperature norms: MedlinePlus Medical Encyclopedia. [online] Medlineplus.gov. Retrieved May 25, 2018, from https://medlineplus.gov/ency/article/001982.htm

Melin, B., & Savourey, G. (2001). Sports and extreme conditions. Cardiovascular incidence in long term exertion and extreme temperatures (heat, cold). La Revue du praticien, 51(12 Suppl), S28-30.

Mell HK, Mumma SN, Hiestand B, Carr BG, Holland T, Stopyra J. Emergency Medical Services Response Times in Rural, Suburban, and Urban Areas. JAMA Surg. 2017;152(10):983–984. doi:10.1001/jamasurg.2017.2230

Mounteverest.net. (n.d.). Retrieved June 2, 2018, from http://www.mounteverest.net/expguide/route.htm

Mukhopadhyay, S. C., & Islam, T. (2018). Wearable Sensors:Applications, design and implementation. IOP Publishing. https://doi.org/10.1088/978-0-7503-1505-0

Nes, B. M., Janszky, I., Wisløff, U., Støylen, A., & Karlsen, T. (2013). Age-predicted maximal heart rate in healthy subjects: The HUNT Fitness Study. Scandinavian Journal of Medicine & Science in Sports, 23(6), 697–704. https://doi.org/10.1111/j.1600-0838.2012.01445.x

Nybo, L. (2012). Brain temperature and exercise performance. Experimental Physiology, 97(3), 333–339. https://doi.org/10.1113/expphysiol.2011.062273

Olsson, J. (2014). 6LoWPAN demystified. Retrieved from http://www.ti.com/lit/wp/swry013/swry013.pdf

Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012). A review of wearable sensors and systems with application in rehabilitation. Journal of neuroengineering and rehabilitation, 9(1), 21.

Persson, M., & Karlsson, D. (2018). U.S. Patent No. US9921293B2. Washington, DC: U.S. Patent and Trademark Office. https://patents.google.com/patent/US9921293B2/en

Price, C., Maor, R., Shachaf, H. (september 2018). Using smartphones for monitoring atmospheric tides. Elsevier Journal of Atmospheric and Solar-Terrestrial Physics. https://www.sciencedirect.com/science/article/pii/S1364682618301937

Replace Direct. (2018). Lithium-polymeer batterijen. Retrieved from https://www.replacedirect.be/nl/batterij-technieken/lithium-polymeer-batterijen.html

Rouse, Margaret. “Serial Peripheral Interface (SPI)”, Last Update: March 2011, http://whatis.techtarget.com/definition/serial-peripheral-interface-SPI

ROYAL DUTCH CLIMBING AND MOUNTAINEERING FEDERATION (NKBV), (2015), retrieved from http://bergsportdag.nkbv.nl/wp-content/uploads/2016/09/Presentatie-NKBV-EN-BSD17.pdf

Schöffl, I., Oppelt, K., Jüngert, J., Schweizer, A., Neuhuber, W., & Schöffl, V. (2009). The influence of the crimp and slope grip position on the finger pulley system. Journal of Biomechanics,42(13), 2183-2187. doi:10.1016/j.jbiomech.2009.04.049

Schweizer, A. (2001). Biomechanical properties of the crimp grip position in rock climbers. Journal of Biomechanics,34(2), 217-223. doi:10.1016/s0021-9290(00)00184-6

SFIA. (n.d.). “Number of participants in climbing (traditional/ice/mountaineering) in the United States from 2011 to 2017 (in millions)”, retrieved from https://www.statista.com/statistics/763799/climbing-traditional-ice-mountaineering-participants-us/

SFIA. (n.d.). “Number of people who went hiking/backpacking within the last 12 months in the United States from spring 2008 to spring 2017 (in millions)”, retrieved from https://www.statista.com/statistics/763799/climbing-traditional-ice-mountaineering-participants-us/

s.n. (2016). Khumbu Icefall: Jason Crossing a Crevasse. Retrieved June 2, 2018, from https://www.youtube.com/watch?v=qHX8UXTWFqI

Solid Energy. (s.d.). Hermes, High Energy Rechargeable Metal Cells for Space. Retrieved from http://assets.solidenergysystems.com/wp-content/uploads/2017/09/08171937/Hermes_Spec_Sheet1.pdf

Sun, H., You, X., Jiang, Y., Guan, G., Fang, X., Deng, J., . . . Peng, H. (2014). Self-Healable Electrically Conducting Wires for Wearable Microelectronics. Angewandte Chemie, 126(36), 9680-9685. doi:10.1002/ange.201405145

Shariff, F., Hingorani, V., L., Albadawi, H., (2015). Monitoring hydration based on galvanic skin response U.S. Patent No. 20160374588A1. Microsoft Technology Licensing LLC

Shu, Y., Li, C., Wang, Z., Mi, W., Li, Y., & Ren, T. L. (2015). A Pressure sensing system for heart rate monitoring with polymer-based pressure sensors and an anti-interference post processing circuit. Sensors, 15(2), 3224-3235.

TBPC Healthcare. (s.d.). Wearable Oximetry module: Module Overview. Retrieved on 20 May 2018, from http://www.tbpchc.com/eng/medical.php?gid=13.

Trofimencoff, T. (Jan 6, 2016). A Flexible and Transparent Pressure Sensor. Retrieved from https://www.engineering.com/DesignerEdge/DesignerEdgeArticles/ArticleID/11409/A-Flexible-and-Transparent-Pressure-Sensor.aspx?e_src=relart

uBlox. (2018). ZOE-M8B Ultra-small, super low power u-blox M8 GNSS SiP module: Data Sheet . Retrieved on 20 May 2018, from https://www.u-blox.com/sites/default/files/ZOE-M8B_DataSheet_%28UBX-17035164%29.pdf

Ullah, S. U., & Baghel, R. K. (2015, October). Hybrid system of electro-textile based wearable microstrip patch antenna with tuning holes. In Soft Computing Techniques and Implementations (ICSCTI), 2015 International Conference on (pp. 135-139). IEEE.

Ultimate Kilimanjaro team, (2018). How Do I Prepare to Climb Kilimanjaro? Kilimanjaro Training, Gear, Visas and Vaccinations. Retrieved May 25, 2018, from https://www.ultimatekilimanjaro.com/preparation.htm

Voinea, G. D., Butnariu, S., & Mogan, G. (2016). Measurement and geometric modelling of human spine posture for medical rehabilitation purposes using a wearable monitoring system based on inertial sensors. Sensors, 17(1), 0003.

West, A. (2016). U.S. Patent No. US20180144307A1. Washington, DC: U.S. Patent and Trademark Office.

Young, C. C. (2002). Extreme sports: injuries and medical coverage. Current sports medicine reports, 1(5), 306-311.

Yuan, Gao, et al., “Low-Power Ultrawideband Wireless Telemetry Transceiver for Medical Sensor Applications,” Biomedical Engineering, IEEE Transactions on, vol. 58 (3), pp. 768–772, 2011.