PRE2020 Group 1 numbers: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(16 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
Return to the main page: [[PRE2020_1_Group1#Numerical_design_data|Main page]] | |||
{| border=1, style="border-collapse: collapse;" cellpadding = 5 | {| border=1, style="border-collapse: collapse;" cellpadding = 5 | ||
Line 66: | Line 13: | ||
|<!--Col2-->10x10 meter | |<!--Col2-->10x10 meter | ||
|<!--Col3-->Range provided by manufacturer | |<!--Col3-->Range provided by manufacturer | ||
|<!--Col4--><ref name="Microphonerange"> | |<!--Col4--><ref name="Microphonerange">[https://static1.squarespace.com/static/5aec19464eddecf8ba36f73e/t/5c8798c4b208fcd94f38328d/1552390343531/Sorama+Smart+City+Listener+2019.pdf] Sorama. Sorama Smart City Listener. </ref> | ||
|- | |- | ||
Line 75: | Line 22: | ||
|- | |- | ||
|<!--Col1--> | |<!--Col1-->Distance between detection device and measurement station | ||
|<!--Col2--> | |<!--Col2-->2 meters | ||
|<!--Col3-->Preferred value | |||
|<!--Col4--> | |||
|- | |||
|<!--Col1-->Percentage of infected people | |||
|<!--Col2-->0.1% | |||
|<!--Col3--> This is the amount of people currently tested positive for COVID-19. Some of these people are in the hospital and do not count, also the people tested positive will be a lot more careful coming into contact with others. However there are also people that have COVID-19 that are not tested. This will even out and so the same percentage of infected people was taken. | |||
|<!--Col4--><ref name="RIVMactueel">[https://www.rivm.nl/coronavirus-covid-19/actueel] RIVM. Actuele informatie over het nieuwe coronavirus.</ref> | |||
|- | |||
|<!--Col1-->Chance of detecting a cough with camera and microphone | |||
|<!--Col2-->87% | |||
|<!--Col3-->Chance obtained by Korean researchers using a similar system | |||
|<!--Col4--><ref name="KoreanStudy">[https://news.kaist.ac.kr/newsen/html/news/?mode=V&mng_no=9470] Center for Noise and Vibration Control KAIST (2020). Deep Learning-Based Cough Recognition Model Helps Detect the Location of Coughing Sounds in Real Time. </ref> | |||
|- | |||
|<!--Col1-->Measurement station cycle time | |||
|<!--Col2-->4 minutes | |||
|<!--Col3-->1 minute testing + 2 minutes disinfecting + 1 spare minute | |||
|<!--Col4--> | |||
|- | |||
|<!--Col1-->Expected false positive rate in measurement station | |||
|<!--Col2-->7% | |||
|<!--Col3-->Study of similar cough classification algorithm achieved 96.6% accuracy. In this specific case this becomes higher than only the cough test since only 1 test needs to be positive to refuse access | |||
|<!--Col4--><ref name = "CoronaCoughApp"> [https://doi.org/10.1016/j.imu.2020.100378] Imran, A., Posokhova, I., Qureshi, H. N., Masood, U., Riaz, S., Ali, K., John, C. N., Hussain, I., & Nabeel, M. (2020). AI4COVID-19: AI enabled preliminary diagnosis for COVID-19 from cough samples via an app. Informatics in Medicine Unlocked, 20, 100378.</ref> | |||
|- | |||
|<!--Col1-->Expected false negative rate in measurement station | |||
|<!--Col2-->7% | |||
|<!--Col3-->Study of similar cough classification algorithm achieved 96.6% accuracy. In this specific case this becomes higher than only the cough test since only 1 test needs to be positive to refuse access | |||
|<!--Col4--><ref name = "CoronaCoughApp"/> | |||
|- | |||
|<!--Col1-->Frequency of random person getting picked out | |||
|<!--Col2-->After every 2 coughing persons detected, 1 person is picked out randomly, if there is no queue | |||
|<!--Col3-->This will ensure random people are not picked too often/not often enough and also random persons will not have to wait in a queue | |||
|<!--Col4--> | |||
|- | |||
|<!--Col1-->Chance a healthy person coughs when in range of the microhpone | |||
|<!--Col2-->0.08% | |||
|<!--Col3-->Based on average cough time and walking speed | |||
|<!--Col4--><ref name="HealthyCough">[http://www.healthofchildren.com/C/Cough.html] Encyclopedia of Children's Health. Cough. </ref> | |||
|- | |||
|<!--Col1-->Estimated cost of the total system | |||
|<!--Col2-->€10950 | |||
|<!--Col3-->€5500 for thermal camera, €1000 for microphones, €100 for microphone in cabin, €400 for camera on pole, €750 for camera pole, €3000 for booth including computer, software, screens, and interfaces, €200 for UV light | |||
|<!--Col4-->Various webshops | |||
|- | |||
|<!--Col1-->Salary of medical personnel | |||
|<!--Col2-->€25 per hour | |||
|<!--Col3--> | |<!--Col3--> | ||
|<!--Col4--> | |<!--Col4-->Obtained from dad of group member who is a salary administrator | ||
|- | |- | ||
|<!--Col1--> | |<!--Col1-->Dutch reproduction rate of COVID-19 | ||
|<!--Col2--> | |<!--Col2-->3 | ||
|<!--Col3--> | |<!--Col3--> | ||
|<!--Col4--> | |<!--Col4--><ref name="RIVMverspreiding"> [https://www.rivm.nl/coronavirus-covid-19/verspreiding] RIVM. Verspreiding COVID-19. </ref> | ||
|- | |- | ||
|<!--Col1--> | |<!--Col1-->Number of people in half an hour entering Heuvel Galerie during a quiet hour at a quiet entrance | ||
|<!--Col2--> | |<!--Col2-->24 | ||
|<!--Col3--> | |||
|<!--Col4-->Counted by group members | |||
|- | |||
|<!--Col1-->Number of people in half an hour entering Heuvel Galerie during a quiet hour at a busy entrance | |||
|<!--Col2-->61 | |||
|<!--Col3--> | |<!--Col3--> | ||
|<!--Col4--> | |<!--Col4-->Counted by group members | ||
|- | |- | ||
|<!--Col1--> | |<!--Col1-->Number of people in half an hour entering Heuvel Galerie during a medium busy hour at a quiet entrance | ||
|<!--Col2--> | |<!--Col2-->117 | ||
|<!--Col3--> | |<!--Col3--> | ||
|<!--Col4--> | |<!--Col4-->Counted by group members | ||
|- | |- | ||
|<!--Col1--> | |<!--Col1-->Number of people in half an hour entering Heuvel Galerie during a medium busy hour at a busy entrance | ||
|<!--Col2--> | |<!--Col2-->194 | ||
|<!--Col3--> | |<!--Col3--> | ||
|<!--Col4--> | |<!--Col4-->Counted by group members | ||
|- | |||
|<!--Col1-->Number of people in half an hour entering Heuvel Galerie during a busy hour at a quiet entrance | |||
|<!--Col2-->233 | |||
|<!--Col3--> | |||
|<!--Col4-->Counted by group members | |||
|- | |||
|<!--Col1-->Number of people in half an hour entering Heuvel Galerie during a busy hour at a busy entrance | |||
|<!--Col2-->756 | |||
|<!--Col3--> | |||
|<!--Col4-->Counted by group members | |||
|} | |} |
Latest revision as of 10:10, 15 October 2020
Return to the main page: Main page
Name | Value | Explanation | Source |
Microphone array range | 10x10 meter | Range provided by manufacturer | [1] |
Microphone mounting height | 2.5 meters | Minimum mounting height provided by manufacturer | [1] |
Distance between detection device and measurement station | 2 meters | Preferred value | |
Percentage of infected people | 0.1% | This is the amount of people currently tested positive for COVID-19. Some of these people are in the hospital and do not count, also the people tested positive will be a lot more careful coming into contact with others. However there are also people that have COVID-19 that are not tested. This will even out and so the same percentage of infected people was taken. | [2] |
Chance of detecting a cough with camera and microphone | 87% | Chance obtained by Korean researchers using a similar system | [3] |
Measurement station cycle time | 4 minutes | 1 minute testing + 2 minutes disinfecting + 1 spare minute | |
Expected false positive rate in measurement station | 7% | Study of similar cough classification algorithm achieved 96.6% accuracy. In this specific case this becomes higher than only the cough test since only 1 test needs to be positive to refuse access | [4] |
Expected false negative rate in measurement station | 7% | Study of similar cough classification algorithm achieved 96.6% accuracy. In this specific case this becomes higher than only the cough test since only 1 test needs to be positive to refuse access | [4] |
Frequency of random person getting picked out | After every 2 coughing persons detected, 1 person is picked out randomly, if there is no queue | This will ensure random people are not picked too often/not often enough and also random persons will not have to wait in a queue | |
Chance a healthy person coughs when in range of the microhpone | 0.08% | Based on average cough time and walking speed | [5] |
Estimated cost of the total system | €10950 | €5500 for thermal camera, €1000 for microphones, €100 for microphone in cabin, €400 for camera on pole, €750 for camera pole, €3000 for booth including computer, software, screens, and interfaces, €200 for UV light | Various webshops |
Salary of medical personnel | €25 per hour | Obtained from dad of group member who is a salary administrator | |
Dutch reproduction rate of COVID-19 | 3 | [6] | |
Number of people in half an hour entering Heuvel Galerie during a quiet hour at a quiet entrance | 24 | Counted by group members | |
Number of people in half an hour entering Heuvel Galerie during a quiet hour at a busy entrance | 61 | Counted by group members | |
Number of people in half an hour entering Heuvel Galerie during a medium busy hour at a quiet entrance | 117 | Counted by group members | |
Number of people in half an hour entering Heuvel Galerie during a medium busy hour at a busy entrance | 194 | Counted by group members | |
Number of people in half an hour entering Heuvel Galerie during a busy hour at a quiet entrance | 233 | Counted by group members | |
Number of people in half an hour entering Heuvel Galerie during a busy hour at a busy entrance | 756 | Counted by group members |
- ↑ 1.0 1.1 [1] Sorama. Sorama Smart City Listener.
- ↑ [2] RIVM. Actuele informatie over het nieuwe coronavirus.
- ↑ [3] Center for Noise and Vibration Control KAIST (2020). Deep Learning-Based Cough Recognition Model Helps Detect the Location of Coughing Sounds in Real Time.
- ↑ 4.0 4.1 [4] Imran, A., Posokhova, I., Qureshi, H. N., Masood, U., Riaz, S., Ali, K., John, C. N., Hussain, I., & Nabeel, M. (2020). AI4COVID-19: AI enabled preliminary diagnosis for COVID-19 from cough samples via an app. Informatics in Medicine Unlocked, 20, 100378.
- ↑ [5] Encyclopedia of Children's Health. Cough.
- ↑ [6] RIVM. Verspreiding COVID-19.